Example: stock market

Ethernet Communication Interface Module

ControlLogix Ethernet Communication Interface Module1756-ENET/BUser ManualImportant User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication , Safety Guidelines for the Application, Installation and Maintenanc

installing, programming, and maintaining a control system that communicates on an Ethernet network through a 1756-ENET/B module. We assume you have a good understanding of Ethernet and the (TCP/IP) protocol. This user manual contains a brief description of Ethernet and TCP/IP in Chapter 3. For detailed information on TCP/IP

Tags:

  Installing, 1756

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Ethernet Communication Interface Module

1 ControlLogix Ethernet Communication Interface Module1756-ENET/BUser ManualImportant User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication , Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office)

2 , describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is this manual we use these notes to make you aware of safety considerations:Warning and Attention statements help you to: identify a hazard avoid a hazard recognize the consequencesAllen-Bradley and ControlLogix are trademarks of Rockwell is a trademark of Digital Equipment Corporation, Intel, and Xerox and RSLogix 5000 are trademarks of Rockwell 95/98 and Windows NT are trademarks of Microsoft !

3 Identifies information about practices or circumstances that have the potential to create an explosion !Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic information that is critical for successful application and understanding of the Communities (EC) Directive ComplianceIf this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following DirectiveThis product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file.

4 EN 50081-2 EMC Generic Emission Standard, Part 2 Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 Industrial EnvironmentThis product is intended for use in an industrial Voltage DirectiveThis product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines, publication style devices must be provided with environmental and safety protection by proper mounting in enclosures designed for specific application conditions.

5 See NEMA Standards publication 250 and IEC publication 529, as applicable, for explanations of the degrees of protection provided by different types of Automation SupportRockwell Automation offers support services worldwide, with over 75 sales/support offices, 512 authorized distributors and 260 authorized systems integrators located throughout the United States alone, as well as Rockwell Automation representatives in every major country in the Product SupportContact your local Rockwell Automation representative for: sales and order support product technical training warranty support support service agreementsTechnical Product AssistanceIf you need to contact Rockwell Automation for technical assistance, call your local Rockwell Automation representative, or call Rockwell directly at: 1 440 presales support, call 1 440 can also obtain technical assistance online from the following Rockwell Automation WEB sites.

6 (knowledge base) (electronic data sheets)Your Questions or Comments on this ManualIf you find a problem with this manual, please notify us of it on the enclosed Publication Problem 1756 -UM051B-EN-P - November 2000 PrefaceAbout This User ManualWhat this Preface ContainsThis preface describes how to use this manual. The following table describes what this preface contains and where to find specific Should UseThis ManualThis manual is intended for control engineers and technicians who are installing , programming, and maintaining a control system that communicates on an Ethernet network through a 1756 -ENET/B Module .

7 We assume you have a good understanding of Ethernet and the (TCP/IP) protocol. This user manual contains a brief description of Ethernet and TCP/IP in Chapter 3. For detailed information on TCP/IP protocol and networking in general, see the following publications: Comer, Douglas E. Internetworking with TCP-IP, Volume 1: Protocols and Architecture, 2nd ed. Englewood Cliffs, : Prentice-Hall, 1995. ISBN 0-13-216987-8. Tanenbaum, Andrew S. Computer Networks, 2nd ed. Englewood Cliffs, : Prentice-Hall, 1989. ISBN information aboutSee pageWho Should Use This ManualP-1 Common Techniques Used in This ManualP-2 How To Use This ManualP-2 About the Example ApplicationsP-3 System ComponentsP-4 Where to Find More InformationP-5 TerminologyP-6 Publication 1756 -UM051B-EN-P - November 2000 P-2 About This User ManualCommon TechniquesUsed in This ManualThe following conventions are used throughout this manual: Bulleted lists provide information, not procedural steps.

8 Numbered lists provide sequential steps. Information in bold contained within text identifies menu windows, or screen options, screen names and areas of the screen, such as dialog boxes, status bars, radio buttons and To Use This ManualThis manual provides an overview of the 1756 -ENET/B Module , as well as general information about Ethernet . It describes how to install and configure the Module , and provides three example applications showing how to use the Module to communicate over Ethernet . The example applications are intended as building blocks to help you get your own network up and running. We recommend that you set up and run the example applications and use them as a guide for setting up your own symbol identifies helpful definition box defines terms that may be unfamiliar to captures are pictures of the software s actual screens.

9 The names of screen buttons and fields are often in bold in the text of a procedure. Pictures of keys represent the actual keys you is a definition box. When a word is bold within the text of a paragraph, a definition box will appear in the left margin to further define the 1756 -UM051B-EN-P - November 2000 About This User Manual P-3 About the Example ApplicationsThe example applications presented in this manual are as follows: Rack Optimized I/O (chapter 5) Using Analog I/O with Direct Connection (chapter 6) Produced and Consumed tags (chapter 7)Here s an example of the type of system you ll be creating for I/O applications.

10 Logix55501756-ENET/B1756-ENET/BDataSlot 0 1 Slot 0 1 2 31756-IB16 IDigital Input1756-OB16 IDigital r m i na lLocal ChassisRemote Chassis1756-OF8 Analog OutputPublication 1756 -UM051B-EN-P - November 2000 P-4 About This User ManualSystem ComponentsWe used the following components for the example applications:Quantity Product NameCatalog NumberHardware2 ControlLogix chassis1756-A4, (or -A7, -A13, -A13, -A17)2 ControlLogix power supply1756-PA72, (or -PB72)2 Ethernet Communications Interface Module1756-ENET/B2 Logix5550 controller1756-L11 Analog Output Module1756-OF81 Digital Input Module1756-IB16I1 Digital Output Module1756-0B16I1 Personal computer that supports RSLogix 5000 softwareAny appropriate model running Windows NT , Service Pack 5 or higher1 Ethernet switch Refer to manufacturer s specificationsAssociated media and connectors as neededSoftware1 RSLinx 9355-WAB, -WABOEM.


Related search queries