Example: bankruptcy

EXCALIBUR 7000 - Robertshaw Industrial

Sales Manual Section 100. Product Specification 7000 . EXCALIBUR 7000 . Microprocessor Based Level Control System FEATURES AND BENEFITS. smart transmitter AND PID. CONTROLLER OPTION W/AUTO. TUNE. MENU DRIVEN SETUP/. CALIBRATION WITH KEYPAD. ENTRY. SETPOINT AND PROCESS. VARIABLE DISPLAYS. TEST/VERIFY PUSH-BUTTON. (REMOTE). FIELD SELECTABLE INPUT. Probe shown for illustration LINEARIZATION FOR OPEN. only. Not included. CHANNEL FLOW OR NON - CYLINDRICAL / HORIZONTAL. VESSELS. OPTIONAL TWO OR FOUR ALARM. GENERAL DESCRIPTION RELAYS W / T. D. & DIFFERENTIAL. CONTINUOUS SELF DIAGNOSTICS. The Robertshaw EXCALIBUR 7000 offers you TWO COMMUNICATION ISOLATED 4-20. INSTRUMENTS FOR THE PRICE OF ONE. Both a mA OUTPUT. smart RF capacitance microprocessor based Level PATENTED PFM transmitter .

1 GENERAL DESCRIPTION The Robertshaw EXCALIBUR 7000 offers you TWO INSTRUMENTS FOR THE PRICE OF ONE. Both a SMART RF capacitance microprocessor based Level Transmitter and PID Controller, this unique instrument

Tags:

  Smart, Transmitter, 7000, Excalibur, Excalibur 7000

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EXCALIBUR 7000 - Robertshaw Industrial

1 Sales Manual Section 100. Product Specification 7000 . EXCALIBUR 7000 . Microprocessor Based Level Control System FEATURES AND BENEFITS. smart transmitter AND PID. CONTROLLER OPTION W/AUTO. TUNE. MENU DRIVEN SETUP/. CALIBRATION WITH KEYPAD. ENTRY. SETPOINT AND PROCESS. VARIABLE DISPLAYS. TEST/VERIFY PUSH-BUTTON. (REMOTE). FIELD SELECTABLE INPUT. Probe shown for illustration LINEARIZATION FOR OPEN. only. Not included. CHANNEL FLOW OR NON - CYLINDRICAL / HORIZONTAL. VESSELS. OPTIONAL TWO OR FOUR ALARM. GENERAL DESCRIPTION RELAYS W / T. D. & DIFFERENTIAL. CONTINUOUS SELF DIAGNOSTICS. The Robertshaw EXCALIBUR 7000 offers you TWO COMMUNICATION ISOLATED 4-20. INSTRUMENTS FOR THE PRICE OF ONE. Both a mA OUTPUT. smart RF capacitance microprocessor based Level PATENTED PFM transmitter .

2 transmitter and PID Controller, this unique instrument PROVIDES DIGITAL. provides the flexibility to meet all your level TRANSMISSION. application requirements. The EXCALIBUR 7000 has UP TO 1 MILE WITH STANDARD. built-in PID Control with AUTO TUNE to eliminate TWISTED PAIR CABLE (NO COAX. offset and provide accuracy and stability. The auto tune OR TRIAX NEEDED). feature eliminates periodic on-line tuning by NEMA 4/4X ENCLOSURES. automatically matching control action with your INTRINSICALLY SAFE PFM. particular process characteristics. This feature alone transmitter , UL/c-UL LISTED. eliminates many hours of fine tuning to your particular (STANDARD & LOW SPAN. process and the need for, and the cost of, a separate VERSIONS ONLY). controller. Patented optional RF anti-coating circuitry eliminates errors due to product build-up on the probe assuring you of accurate level measurements in all types of coating applications.

3 1. Robertshaw 's patented Pulse Frequency Modulated requirements. Power supply requirement is 120/240. (PFM) transmitter technology provides digital VAC that is switch selectable in the field. Output is transmission up to 1 mile using economical standard isolated 4-20 mA. Adjustable response time to handle twisted pair wire. This eliminates the cost of more agitated or wavy processes is standard. expensive coaxial or triaxial cable and provides no-loss accuracy eliminating errors typically found Continuous Self-Diagnostics and remote Test/Verify with analog transmission. Built in field selectable push-button insure you of constant reliability and input linearization allows open channel flow safety. Error codes appear on the vacuum Fluorescent measurement and level control with volume Display when failures occur.

4 This self-monitoring conversions for non-cylindrical or horizontal feature increases instrument stability and accuracy, cylindrical vessels. Setup is simple - just select from eliminating the need for ongoing manual calibration the menu. This eliminates programming at the checking, reducing downtime, and improving system factory, entering of time consuming strapping tables, performance and quality control. It permits early and allows the user flexibility to use the same detection and identification of sensing problems controller if his application changes. before they lead to a major breakdown. The test feature allows conformance to local and federal Simple menu prompts guide you step-by-step through environmental regulations. all Setup and Calibration. No technical knowledge is required.

5 Entry is by built-in keypad A variety of sensing probes are available to suit any Everything can be done with direct keypad entry. application; high temperature/pressure, sanitary, Calibration can also be accomplished without flanged, inactive lengths, grounded for non-metal completely emptying or filling the vessel. This feature vessels, rigid, flexible, bare or insulated. Lengths are is in-valuable where tanks are emptied and filled only available up to 100 feet. once or twice a year during shutdown. All Setup and Calibration entries can be password protected with a In summary, the EXCALIBUR 7000 packs more selection of three distinct levels of access. Calibration features and benefits into one package than you will also offers selection of Engineering Units, type of find anywhere.

6 It provides local or remote calibration variable(s) to be displayed, measurement of level and capability, greater measurement accuracy/stability, /or volume or flow, etc. Non-volatile memory insures lower startup costs, reduced maintenance costs, setup and calibration data is retained if electrical quality control, and lower design costs. It provides power is lost. No battery backup is required. flexibility of configuration or reconfiguration. Features and options can easily be added in the field Displays are abundant to keep you informed of setup by simple plug in modules. It provides parameters selected, calibration data, setpoint, process self-monitoring/self diagnostic capability. This variable, alarm status, error codes, etc. In all there are transmitter /controller will suit ALL your level two (2) five digits LED displays ( one green and one Applications save time, money, and reduce your red), typically used to display the measured variable parts inventory.

7 Applications are unlimited!!! These and control setpoint; one 2 line by 20 character include level and/or interface control in all storage or alpha-numeric vacuum fluorescent display (visible in process vessels containing liquids, granulars or any type of lighting) for menu prompts during slurries. This includes the chemical/petrochemical, setup/calibration and configurable as to the data petroleum refining, water/wastewater, food and displayed during normal operation; eight (8) LED beverage, electric power, pulp and paper, controller status indicators and eight (8) LED alarm pharmaceutical, mining and primary metals industries. status indicators. These displays give you a wealth of information at a glance. Relay options include two or four SPDT 10 amp relays with independent selectable differential and time delay on each.

8 All relays are also field selectable High or Low Level Fail Safe to suit the customer's particular safety 2. Specifications Electrical/Electronic: Supply Voltage .. 120/240 VAC 10%, Environmental: 50/60 Hz switch selectable. Temperature (Operating or Storage): Supply 20VA. Max. -40 to +140 F (-40 to +60 C). Measurement Range: Relative Humidity .. 0 to 95%, Non-Condensing With Standard PFM transmitter (1 range): 10 to 6000 pF Vibration .. 2 G, 10 to 200Hz With Low Span PFM transmitter (1 range): Shock .. 75G's for 11msec. without permanent damage 2 to 335 pF. Enclosure: Resolution .. of Span PFM transmitter Raintight, NEMA 4. Accuracy .. Typical Optional Rain tight, NEMA 4X, epoxy painted Repeatability .. Controller Non-metallic UL Listed Type 4X and Ambient Temperature Effect.

9 F CSA Certified Type 4X. Weights: Alarm Set point .. 0 to , Resolution Standard PFM transmitter .. lbs ( kg). Low Span PFM transmitter .. lbs ( kg). Alarm Differential .. 0 to , Resolution Non-metallic Controller .. lbs ( kg). Alarm Time Delays .. 0 to 60 seconds Intrinsic Safety: second resolution Standard & Low Span PFM Transmitters and Probe are Relay Output .. Optional certified as intrinsically safe for Class I, Division 1, Type-Electromechanical contacts Groups A, B, C Class II, Division 1, Groups E, F. SPDT, 8A @ 30 VDC, 10A @ & G and Class I, Zone 0, Group IIC when connected as 250 VAC GP, 5A @ 120 VAC shown on drawing #907GA811 (barrier required). IND, 1/3 HP @ 120 VAC. Agency Certifications: Analog Output .. Optional Standard PFM transmitter .. UL & c-UL Listed 4-20 mADC into a 650 ohm load Low Span PFM transmitter .

10 UL & c-UL Listed max. Controller .. None Maximum Distance Between EMC Emissions & Immunity Conformity: transmitter and Controller .. One (1) mile Standard PFM transmitter .. CE & FCC. Low-Span PFM transmitter .. CE & FCC. Interconnecting Cable Between Controller .. None transmitter and Controller .. Two (2) wire, twisted pair recommended. Similar to Belden #8205 (unshielded), or #8762. (shielded). ntal: 3. 4. PFM DIMENSIONS. transmitter A B. STANDARD (146) (89). LOW SPAN (146) (89). ANTI-COATING (208) (102). PFM transmitter : Outline Dimensions: 5. 6. ORDERING INFORMATION. Base Model Number Table 6 - PFM transmitter Model No. Description Desig. Description 7000 EXCALIBUR 7000 , Microprocessor-based 1 Standard, Probe Mounted, NEMA 4. level control system. Consisting of a 2 Standard, Probe Mounted, NEMA 4X.


Related search queries