EXPANSION TANKS - U. S. Craftmaster

Available As Hydronic Or Potable Water EXPANSION TanksDrawn Steel ConstructionHeavy Duty Butyl DiaphragmIAPMO ApprovedMax. Working pressure 150 PSI For Potable Water EXPANSION Tanks100 PSI For Hydronic EXPANSION TanksWarranty5-year Potable EXPANSION Tanks1-year Hydronic EXPANSION TanksEXPANSION TANKST hermal EXPANSION occurs when water is heated during non-use periods. The installation of aPressure Reducing Valve (PRV), Check Valve or Back Flow Preventer closes the water system,leaving water with no room for EXPANSION . National Standard Plumbing code: requiresbackflow prevention, to prevent backflow into the water EXPANSION in a closed plumbing system can be damaging, dangerous and costly. Its effectsinclude damage to water heater connections,gas water heater flue tubes, pumps serving washers anddishwashers,leaking faucets, weeping of water through the water heater T&P Safety Valve,and noisywater hammer in the properly sized Craftmaster EXPANSION Tank eliminates these by giving water a place to go when thermal EXPANSION occurs.

POTABLE WATER EXPANSION TANKS Maximum Working Pressure:150 PSI Maximum Temperature:140°F Residential 180°F Commercial For use with residential and commercial water heaters In-line design,with 3⁄4˝ NPTM connection: installs in cold water line of water heater Field-adjustable 40 PSI air charge Drawn-steel tank with 2-coat bonded ...

Tags:

  Pressure, Expansion, Cold, Tanks, Expansion tanks

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EXPANSION TANKS - U. S. Craftmaster

1 Available As Hydronic Or Potable Water EXPANSION TanksDrawn Steel ConstructionHeavy Duty Butyl DiaphragmIAPMO ApprovedMax. Working pressure 150 PSI For Potable Water EXPANSION Tanks100 PSI For Hydronic EXPANSION TanksWarranty5-year Potable EXPANSION Tanks1-year Hydronic EXPANSION TanksEXPANSION TANKST hermal EXPANSION occurs when water is heated during non-use periods. The installation of aPressure Reducing Valve (PRV), Check Valve or Back Flow Preventer closes the water system,leaving water with no room for EXPANSION . National Standard Plumbing code: requiresbackflow prevention, to prevent backflow into the water EXPANSION in a closed plumbing system can be damaging, dangerous and costly. Its effectsinclude damage to water heater connections,gas water heater flue tubes, pumps serving washers anddishwashers,leaking faucets, weeping of water through the water heater T&P Safety Valve,and noisywater hammer in the properly sized Craftmaster EXPANSION Tank eliminates these by giving water a place to go when thermal EXPANSION occurs.

2 When a water heating cycle ends, or when any fixture is opened within the system, the impact of thermal EXPANSION is reduced, and water drains out of the EXPANSION tank back into the TANKS are pre-charged with a 40 PSI air charge. If the inlet water pressure is higher than40 PSI,the EXPANSION tank s air pressure must be adjusted to match that pressure but must not behigher than 80 , Craftmaster Sizing Chart for Residential Water HeatersWater Heater Capacity in GallonsInlet WaterPressure*304050668210040 PSIAET-2 AET-2 AET-2 AET-2 AET-5 AET-550 PSIAET-2 AET-2 AET-2 AET-2 AET-5 AET-560 PSIAET-2 AET-2 AET-2 AET-2 AET-5 AET-570 PSIAET-2 AET-2 AET-2 AET-2 AET-5 AET-580 PSIAET-2 AET-5 AET-2 AET-5 AET-5 AET-5*Highest recorded inlet water pressure in a 24-hour period of regulated WATER EXPANSION Craftmaster Sizing Chart for Commercial Water HeatersWater Heater Capacity in GallonsWater Temperature3040506682100120140 AET-2 AET-2 AET-5 AET-5 AET-5 AET-10 AET-10150 AET-2 AET-2 AET-5 AET-5 AET-5 AET-10 AET-10160 AET-5 AET-5 AET-5 AET-5 AET-5 AET-10 AET-10170 AET-5 AET-5 AET-10 AET-10 AET-10

3 AET-10 AET-10180 AET-5 AET-5 AET-10 AET-10 AET-10 AET-10 AET-10 FOUNDED1926 UPCRPOTABLE WATER EXPANSION TANKSnMaximum Working pressure : 150 PSInMaximum Temperature: 140 F Residential180 F CommercialnFor use with residential and commercial water heatersnIn-line design, with 3 4 NPTM connection:installs in cold wat er line of wat er heaternField-adjustable 40 PSI air chargenDrawn-steel tank with 2-coat bonded polymer inner lining nButyl diaphragm, for permanent separation of air and wat er, with no waterloggingn2-Gallon (AET-2), 5-Gallon (AET-5) and 10-Gallon (AET-10)nIAPMO ApprovednNSF certified to NSF/ANSI 61n5-Year Limited Craftmaster Water Heater EXPANSION TanksMaximum AcceptableDimensionsVolume (Gallons)in InchesShippingGallonWeightModel NumberCapacity40 PSI60 PSIAB(Lbs.)

4 8121 8143 8153 420 All Models: 150 PSIG Maximum Working pressure , 3/4 NPTM Craftmaster Space Heating EXPANSION TanksMaximum DimensionsAcceptablein InchesShippingVolumeWeightModelGallon(Ga llons)NumberCapacity20 PSIGAB(Lbs.) 8121 8143 8211 8153 422 All Models: 100 PSIG Maximum Working pressure ,1 2 NPTM connectionsSizing based on the followingoperating conditions: Coldpressure 12 PSI, Relief set 30 PSI,maximum temperature 240 shown are for fin-tubedbaseboard radiation. Forsystems with converters and/orunit heaters, increase tank onesize. For cast-iron radiation,increase tank two larger systems, it will benecessary to calculate theexpansion of water within thesystem. Our engineeringdepartment can assist you,ifyou provide the size of thesystem in gallons, the pressure ,and the maximum operatingtemperature.

5 If you do notknow the system capacity, it canbe calculated from the amountand size of pipe used. Craftmaster Sizing GuideNet Boiler OutputRecommended in1000s of Btu sTank(s)25 50 AEH-275 150 AEH-5175 200 AEH-7200 400 AEH-14 BAIN-LINEHYDRONIC EXPANSION TANKSFor use with space heating boilers in closed systems not for use with potable water heating systemsModels up to gallons feature in-line design forinstallation directly into system pipingField-adjustable 12 PSI air chargeDrawn-steel tankButyl diaphragm,for permanent separation of air andwater,with no waterloggingMaximum Working pressure :100 PSIM aximum Temperature:240 F1-Year Limited Craftmaster EXPANSION TANKS for closed space heating systems provide a place for expanding water to go during cycles of thermal EXPANSION ,eliminating the risk of damage to the boiler and piping in the 0807 2007 American Water Heaters.

6 All rights Box 4056500 Princeton RoadJohnson City,TN 37602-4056(800) 937-1037(800) 581-7224 fax