Example: air traffic controller

Explosion Proof Switch - Class 1 Div 1 and Class 2 Div 1

Page: 1 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: Proof Switch - Class 1 Div 1 and Class 2 Div 1 Part #: EPL-SW1 The Larson Electronics EPL-SW1 Explosion Proof Feed Through Tumbler Switch is UL Listed Class 1 Division 1 & 2 and Class 2 Division 1 & 2 and provides a safe and secure method for operators to interrupt power before connecting and disconnecting portableor stationary electrical devices and equipment in hazardous Explosion Proof tumbler Switch is ideal for operators seeking a high quality Explosion Proof Switch rated for use in hazardous areasdesignated Class 1 Division 1 and Class 2 Division 1. This Explosion Proof Switch is rated at 20 amps-120-277 Vac and 1 HP at 120 Vac and 2HP at 240 Vac.

Page: 1 Larson Electronics LLC www.LarsonElectronics.com 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: 903.498.3364 Email: sales@LarsonElectronics.com

Tags:

  Switch, Class, Proof, Explosion, Explosion proof switch class

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Explosion Proof Switch - Class 1 Div 1 and Class 2 Div 1

1 Page: 1 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: Proof Switch - Class 1 Div 1 and Class 2 Div 1 Part #: EPL-SW1 The Larson Electronics EPL-SW1 Explosion Proof Feed Through Tumbler Switch is UL Listed Class 1 Division 1 & 2 and Class 2 Division 1 & 2 and provides a safe and secure method for operators to interrupt power before connecting and disconnecting portableor stationary electrical devices and equipment in hazardous Explosion Proof tumbler Switch is ideal for operators seeking a high quality Explosion Proof Switch rated for use in hazardous areasdesignated Class 1 Division 1 and Class 2 Division 1. This Explosion Proof Switch is rated at 20 amps-120-277 Vac and 1 HP at 120 Vac and 2HP at 240 Vac.

2 The entire unit is constructed of malleable iron and contains an internal sealing chamber constructed of copper free unit is easily wall mounted via integral mounting tabs at two corners of the housing and provides two 1/2" hub openings located on the topand the bottom of the housing for running electrical conductors in a feed through configuration. A bushing seal at each conductor openingprevents damage to wiring unit is rated to handle electrical loads of 120-277 VAC up to 20 amps and is suitable for use in environments where combustible dusts andparticulates may be EPL-SW1 Explosion Proof Switch cover and housing box is constructed of malleable iron with all arcing devices contained within anexplosion Proof labyrinth Switch for the highest protection possible.

3 This design does not require external sealing fittings. Each 1/2` hub openingis fitted with an integral bushing to prevent fraying or damage to insulation. Two external mounting lugs provide simple and secure mounting ofthe unit to walls and flat surafces. The unit box, Switch , and face plate are all included with the " NPT tapped conduit openings are provided on the top and bottom of the unit in feed through versions while dead end versions have a singleconduit hub, providing easy and secure connection to main power line Applications: Manufacturing, Industrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where Combustible Dust is : 2 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: This product does not qualify for free shipping.

4 Part #: EPL-SW1 (46876)Specifications / Additional InformationEPL-SW1 Explosion Proof Tumbler SwitchCertifications - ComplianceSwitch Voltage Rating: 120-277 VACC lass 1 Division 1 & 2 Groups B, C, DSwitch Current Rating: 20 Amps- 1 HP @120 Vac & 2 HP @ 240 VacClass 2 Division 1 & 2 Groups E, F, GGrounding: Single Internal Housing Ground ScrewClass 3 Configuration: Feed Through, Front SwitchNEMA 4 Hub Qty: (2) Feed Through or (1) Dead EndNEMA 7 Groups C & D Hub Size: ) Feed Through or (1) Dead EndNEMA 9 Groups E, F, GUnit Materials: Box/Receptacle- Malleable Iron, Sealing Chamber-AluminumFinish: Triple-coat Zinc Electroplate, Chromate, Epoxy powder coatInsulation: Integral Bushings in Conductor OpeningsSpecial Orders- RequirementsMounting: External Mounting Lugs on BodyContact us for special requirementsUnit Dimensions: "-W X "-D X "-LToll Free: 1-800-369-6671 Switch Type: Single PoleFax: 1-903-498-3364E-mail: Down to Purchase- Page: 3 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: EPL-SW1- HUB SIZE - TERMINATION - WAY Example: SIZE 1/2 Inch 3/4 Inch 1 inch -1 INTERMINATION Feed-Thru -FT Dead-End -DEWAY Single Pole -1P Dual Pole -2P 3-Way -3 WPage: 4 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email.

5 5 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: 6 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: 7 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: 8 Larson Electronics LLC E US HWY 175, Kemp, TX 75143 Phone: 1 800-369-6671 Fax: Email: (Click on the below items to view): - Dimensional Drawing - Manual - STEP - High Res Pic 1 - Explosion Proof Switch (Right Angle) - High Res Pic 2 - Explosion Proof Switch (Front) - High Res Pic 3 - Explosion Proof Switch (Left Angle) - High Res Pic 4 - Explosion Proof Switch (Right Side) - High Res Pic 5 - Explosion Proof Switch (Back) - High Res Pic 6 - Explosion Proof Switch (Left Side) - High Res Pic 7 - Explosion Proof Switch (Bottom) - High Res Pic 8 - Explosion Proof Switch (Top)