FOAMULAR 150. Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet to moisture, and freeze/thaw Product type cycling. Minimum compressive strength Key Features of 15 psi Excellent long-term stable Wide selection of sizes and insulating performance at R-51 thicknesses per inch Available in square, tongue and Exceptional moisture resistance, groove or scored square edge long-term durability Compliant with building codes 2. Limited lifetime warranty and standards maintains 90% of R-value Energy-Saving, Moisture and covers all ASTM C578 Product Applications Resistant XPS Insulation properties High-performance FOAMULAR . ASTM C578 Type X, 15 psi 150 XPS Insulation : minimum The only XPS foam to be GREENGUARD Children Retards the transmission of Description & Schools CertifiedSM water vapor and moisture in Owens Corning FOAMULAR masonry walls 150 Extruded Polystyrene The only XPS foam with (XPS) Insulation is a closed cell, certified r

Because rigid foam plastic insulation products are not all aged in accordance with the same ... commonly used to compare products and is the value printed on the product. 4. Values at yield or 10% defl ection, whichever occurs fi rst. 5. Value at yield or 5%, whichever occurs fi rst.

Tags:

  Printed, Rigid

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Extruded Polystyrene (XPS) Rigid Foam Insulation Product ...

1 FOAMULAR 150. Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet to moisture, and freeze/thaw Product type cycling. Minimum compressive strength Key Features of 15 psi Excellent long-term stable Wide selection of sizes and insulating performance at R-51 thicknesses per inch Available in square, tongue and Exceptional moisture resistance, groove or scored square edge long-term durability Compliant with building codes 2. Limited lifetime warranty and standards maintains 90% of R-value Energy-Saving, Moisture and covers all ASTM C578 Product Applications Resistant XPS Insulation properties High-performance FOAMULAR . ASTM C578 Type X, 15 psi 150 XPS Insulation .

2 Minimum The only XPS foam to be GREENGUARD Children Retards the transmission of Description & Schools CertifiedSM water vapor and moisture in Owens Corning FOAMULAR masonry walls 150 Extruded Polystyrene The only XPS foam with (XPS) Insulation is a closed cell, certified recycled content Provides continuous Insulation moisture-resistant Rigid foam certified by Scientific over steel stud framing, in board well suited to meet the Certification Systems (SCS) insulated concrete sandwich need for a wide variety of building to contain a minimum 20% panel walls, or in masonry unit FOAMULAR recycled content cavity walls, or when used 150 XPS Insulation is ideal for with non-penetrating, surface Will not corrode, rot or mounted furring systems over many residential and commercial support mold growth construction applications such as masonry or concrete walls wall furring, perimeter/foundation, Zero ozone depletion potential Insulates and retains its cavity wall, pre-cast concrete, with 70% less global warming properties in below grade crawl spaces.

3 Sheathing and other potential than our previous perimeter and foundation applications3. FOAMULAR 150 formula applications, to complement the XPS Insulation is classified as a insulating sheathing envelope Type X Product when tested in Reusable around the building framing accordance with ASTM C578 Lightweight, durable Rigid and provides a long-term thermal foam panels are easy to handle FOAMULAR 150 XPS. performance of R-5 per inch. and install Insulation is ideal for below grade applications. Extruded Like all FOAMULAR XPS Easy to saw, cut or score Polystyrene (XPS) is resistant products, FOAMULAR 150 to degradation from the XPS Insulation is made with Versatile applications: sheathing, components of common soils Owens Corning's patented foundation walls, masonry and will retain its insulating Hydrovac process technology cavity walls3 performance characteristics under strict quality control even after prolonged exposure measures, which makes it Not for use in roofing.

4 For to moisture. highly resistant to moisture and roofing applications, use permits the Product to retain FOAMULAR THERMAPINK . it's high R-value year after year Extruded Polystyrene Insulation even after prolonged exposure FOAMULAR 150. Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet Provides a weather resistant Typical Physical Properties1. barrier (when joints are FOAMULAR 150 Extruded Polystyrene Insulation sealed) to enhance the building Property Test Method2 Value resistance to air and moisture Thermal Resistance3, R-Value (180 day) minimum, hr ft 2 F/Btu (RSI, C m2 /W). penetration. @ 75 F (24 C) mean temperature ASTM C518.

5 1" Thickness ( ). 1 " Thickness ( Technical Information 2" Thickness 10 ( ). This Product is combustible. A 2 " Thickness ( ). 3" Thickness 15 ( ). protective barrier or thermal @ 40 F ( C) mean temperature barrier is required as specified 1" Thickness ( ). 1 " Thickness ( ). in the appropriate building 2" Thickness ( ). code. For additional information, 2 " Thickness ( ). consult MSDS or contact Owens 3" Thickness ( ). Long Term Thermal Resistance, LTTR-Value3, minimum Corning World Headquarters at hr ft 2 F/Btu (RSI, C m2 /W). 1-800-GET-PINK . @ 75 F (24 C) mean temperature CAN/ULC S770-03. 1" Thickness ( ). 1 " Thickness ( ). All construction should be 2" Thickness ( ).)

6 Evaluated for the necessity to 2 " Thickness ( ). 3" Thickness ( ). provide vapor retarders. See Compressive Strength4, minimum psi (kPa) ASTM D1621 15 (103). current ASHRAE Handbook of Flexural Strength5, minimum psi (kPa) ASTM C203 60 (414). Fundamentals. Water Absorption 6, maximum % by volume ASTM C272 Water Vapor Permeance7, maximum perm (ng/Pa s m2) ASTM E96 (86). FOAMULAR 150 XPS Insulation Dimensional Stability, maximum % linear change ASTM D2126 Flame Spread 8, 9 ASTM E84 5. is a non-structural material and Smoke Developed 8, 9, 10 ASTM E84 45-175. must be installed on framing Oxygen Index8, minimum % by volume ASTM D2863 24.

7 Which is independently braced Service Temperature, maximum F ( C) 165 (74). and structurally adequate to meet Linear Coefficient of Thermal Expansion, in/in/ F (m/m/ C) ASTM E228 x 10 -5 ( x 10 -5). required construction and service 1. Properties shown are representative values for 1" thick material, unless otherwise specified. 2. Modified as required to meet ASTM C578. loading conditions. 3. R means the resistance to heat flow; the higher the value, the greater the Insulation power. This Insulation must be installed properly to get the marked R-value. Follow the manufacturer's instructions carefully. If a manufacturer's fact sheet is not provided with the material shipment, request this and review it carefully.

8 R-values vary depending FOAMULAR Insulation can be on many factors including the mean temperature at which the test is conducted, and the age of the sample at exposed to the exterior during the time of testing. Because Rigid foam plastic Insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR XPS Insulation is provided normal construction cycles. from testing at two mean temperatures, 40 F and 75 F, and from two aging (conditioning) techniques, 180 day real- time aged (as mandated by ASTM C578) and a method of accelerated aging sometimes called Long Term Thermal During that time some fading Resistance (LTTR) per CAN/ULC S770-03.

9 The R-value at 180 day real-time age and 75 F mean temperature is of color may begin due to UV commonly used to compare products and is the value printed on the Product . 4. Values at yield or 10% deflection, whichever occurs first. exposure, and, if exposed for 5. Value at yield or 5%, whichever occurs first. extended periods of time, some 6. Data ranges from to value shown due to the level of precision of the test method. 7. Water vapor permeance decreases as thickness increases. degradation or dusting of the 8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions.

10 9. Data from Underwriters Laboratories Inc. classified. See Classification Certificate U-197. Polystyrene surface may begin. It 10. ASTM E84 is thickness-dependent, therefore a range of values is given. is best if the Product is covered within 60 days to minimize degradation. Once covered, the deterioration stops, and damage is limited to the thin top surface layers of cells. Cells below are generally unharmed and still useful Insulation . FOAMULAR 150. Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet Product and Packaging Data FOAMULAR 150 Extruded Polystyrene Insulation Material Packaging Extruded Polystyrene closed cell foam, ASTM C578 Type X, 15 psi minimum Shipped in poly-wrapped units with individually wrapped or banded bundles.