Example: stock market

Fact: Flammable gases, vapors, mists and dust as …

Fact: Flammable gases, vapors, mists and dust as small as .03mm are explosive safety concerns when oxygen (air) is present and ignited. Warren Rupp guarantees that its AODD pumps are your insurance for full ATEX Compliance, providing 100% groundability with conductive materials of construction and ensuring no static electricity build-up for ignition-free these potential explosive safety concerns by understanding regional protective specifications, laws, regulations and 40 Years Explosive Atmosphere Industry Experience!Solution: Explosive Atmosphere Duty Pumpsfrom Warren Rupp For Explosive Atmosphere Duty Chemical Petro Chemical Food Processing Oil & Gas MiningATEX (atmosph res Explosibles) is an acronym for the standardset by the European Parliament & Council of the European Union, recognized throughout the European Community as the safety standard for equipment used in potentially hazardous are the assurances of full compliance?

ATEX (atmosphères Explosibles) is an acronym for the standard set by the European Parliament & Council of the European Union, recognized throughout the European Community as the safety standard for equipment used in …

Tags:

  Standards

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fact: Flammable gases, vapors, mists and dust as …

1 Fact: Flammable gases, vapors, mists and dust as small as .03mm are explosive safety concerns when oxygen (air) is present and ignited. Warren Rupp guarantees that its AODD pumps are your insurance for full ATEX Compliance, providing 100% groundability with conductive materials of construction and ensuring no static electricity build-up for ignition-free these potential explosive safety concerns by understanding regional protective specifications, laws, regulations and 40 Years Explosive Atmosphere Industry Experience!Solution: Explosive Atmosphere Duty Pumpsfrom Warren Rupp For Explosive Atmosphere Duty Chemical Petro Chemical Food Processing Oil & Gas MiningATEX (atmosph res Explosibles) is an acronym for the standardset by the European Parliament & Council of the European Union, recognized throughout the European Community as the safety standard for equipment used in potentially hazardous are the assurances of full compliance?

2 Products marked with the EX hexagon symbol followed by the Group and Category of safety protection indicates that the products are compliant with Directive 94/9 is ATEX?Recognize the components of ATEX Compliant Pumps!*Warren Rupp Non-MetallicPumps fully comply with atEX requirements!atEX compliant WaRREN RUPP Pump CONDUCTIVE (ATEX Compliant) NON-CONDUCTIVE (Not ATEX Compliant) *conductive Non-conductive Polypropylene 40% Glass-Filled Polypropylene *conductive Carbon-Filled Non-conductive Polypropylene Polypropylene (*Models: S05, S1F, S15, S20) *conductive Carbon-Filled PVDF Non-conductive PVDF (*Models: S05, S1F)Fully groundableElectrical continuityElectro-Static discharges are dissipated in a continual current path throughout the pump to a natural groundNo isolated metallic hardware componentsNon- Wetted WettedATEX SAFETY bENEFITSNot groundableNo electrical continuityNon-conductive components exceed cm2 (the maximum exposed surface area) required by the ATEX standardIsolated metallic hardware componentsNon-compliant WaRREN RUPP and competitive BrandsCAUTIONUse of grounding straps and/or fluid grounding practices do Not ensure safety or atEX compliancyValue Added Costfor Compliance and Safety150125100 Non-ATEXR elative CostATEX1"2" "1 "II 2GD T5 Warren Rupp self-declares compliance with the safety requirements according to ANNEX VIII of this directive.

3 This safety compliance includes: Filing a Technical Risk Assessment File AX1 with the notified body (Warren Rupp files with KEMA Quality, The Netherlands, Notified Body 0344 under Document 203040000). Requirements for compliance include, but are not limited to: Due analysis of equipment and protective systems Marking all equipment and protective systems Accompanying all equipment and protective systems by instructions Precise selection of spark-free materials Analysis of hazards arising from different ignition sources Filing a Declaration of Conformity with the notified body Including the Declaration of Conformity with the shipment of every Warren Rupp ATEX compliant pumpTec hnical Documentation File No. AX1 Warren Rupp Tradenames: SANDPIPER , Tranquilizer and MARATHON Air-Operated Double Diaphragm Metal Pump Models EH, ET, G, HDB, HDF, M, MHP, MS, MP, PB, SH, S, SA, SB, ST, T & U Series, Metal Surge Suppressors Series T and to ATEX 100a Directive 94/9/ECEquipment intended for use in Potentially Explosive M13 May, 2003 Revision c, 12 January, 2007In accordance with Directive 94/9/EC, Annex VIII Equipment intended for use in potentially explosive environments.

4 Technical File No. AX1 is stored at KEMA,Notified Body 0344, under document number of ConformityATEX 100aModels:Air-Operated Double Diaphragm Metallic Pumps Series: EH, ET, G, HDB, HDF, M, MHP, MS, MP, PB, SH, S, SA, SB, ST, T and U under SANDPIPER and MARATHON BrandsMetal Surge Suppressors Series: T and MSS under Tranquilizer and MARATHON BrandsAir-Operated Double Diaphragm Nonmetallic Conductive Acetal Pump Models: PB and S05 Air-Operated Double Diaphragm Nonmetallic Conductive Polypropylene Pump Models: S05, S1F, S15, S20 Manufacturer:Warren Rupp, North Main Box 1568 Mansfield, OH 44902 USA Applicable Standard: 94/9/ECEN13463-1 For potentially explosive environmentsGroup I, Category M2 Group II, Category 2 GDDavid Roseberry, Engineering ManagerDATE/APPROVAL/TITLE:8 May 2003 Rev F 12 January 2007A WARREN RUPP PUMP BRANDSANDPIPER A WARREN RUPP PUMP BRAND Warren Rupp s self-declared use of the ATEX mark and the documentation we provide is our published guarantee of compliance with the requirements of the Directive and the safety of our Compliance offers important SAFETY bENEFITS.

5 FULLY Groundable Spark-FREE ATEX Compliant means SAFE for use of equipment in potentially explosive environmentsWorld Leader in Fully Compliant ATEX AODD PumpsATEX Compliant I M2 c T52II 2GD T5 HEAVY DUTY BALL VALVE1" SB1 42 gpm (159 l/min)1 " HDB1 90 gpm (340 l/min)2" HDB2 135 gpm (511 l/min)3" HDB3 260 gpm (984 l/min)4" HDB4 260 gpm (984 l/min)HEAVY DUTY FLAP VALVE1" SA1 42 gpm (159 l/min)2" HDF2 140 gpm (530 l/min)3" HDF3 260 gpm (984 l/min)4" HDF4 260 gpm (984 l/min)STANDARD DUTY METALLIC " X02 gpm ( l/min) " S05 15 gpm (57 l/min)1" S1F 45 gpm (170 l/min)1 " S15 106 gpm (401 l/min)2" S20 150 gpm (568 l/min)3" S30 238 gpm (901 l/min)STANDARD DUTY NON-METALLIC " PB 4 gpm (15 l/min) " S05 14 gpm (53 l/min)1" S1F 45 gpm (170 l/min)1 " S15 100 gpm (378 l/min)2" S20 160 gpm (606 l/min)CONTAINMENT DUTY METALLIC1" ST1-A 42 gpm (159 l/min)1 " ST1 -A 90 gpm (340 l/min)HIGH PRESSURE 2:12" SH2 Flap 62 gpm (235 l/min)2" GH2 Gas 62 gpm (235 l/min)MATERIALSSIZE MODELS MAX FLOW Non-Metallic Metallic CP PP K NY CA CV AL CI2 SS2 HC2 K = PVDF NY = Nylon CA = Conductive Acetal CV = Conductive PVDF CP = Conductive Polypropylene PP = Polypropylene AL = Aluminum CI = Cast Iron SS = Stainless Steel HC = Alloy CHeavy Duty BallHDBH eavy Duty FlapHDFSDS tandard DutyMetallic & Non-MetallicContainment fully Groundable, Ignition-Free, Safe, Air-Operated Double Diaphragm TechnologyIDEX AODD, North Main StreetMansfield, OH 44901 USAP hone by: SANDPIPER and ESADS+Plus are registered trademarks of IDEX AODD, Inc.

6 Copyright 2009. All rights