Example: marketing

Fail-Safe ORM LED LD4 Healthcare: Operating …

Fail-Safe D ES C R IPTION. Type Catalog #. Fail-Safe 's development of the asymmetric/symmetric ORM LED. represents the latest technology in precise control of light to the surgical task and to the surrounding area, and allows multi-level lighting without Project changing the character of the lighting distribution. The ORM LED's high efficiency and precise lighting distribution delivers high illumination to Date Comments the surgical task area. Quality and value are maintained to provide the best performance solution for your design needs. Prepared by S PEC IFIC A TION FEA T U R E S.

Failae ORM LED 2x2 2x4 1x4 LD4 LED Healthcare: Operating Room RECESSED FLANGE RECESSED GRID SPECIFICATION FEATURES Mounting Recessed grid or flange, ceiling

Tags:

  Operating, Healthcare, Room, Recessed, Operating room recessed, Led healthcare

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Fail-Safe ORM LED LD4 Healthcare: Operating …

1 Fail-Safe D ES C R IPTION. Type Catalog #. Fail-Safe 's development of the asymmetric/symmetric ORM LED. represents the latest technology in precise control of light to the surgical task and to the surrounding area, and allows multi-level lighting without Project changing the character of the lighting distribution. The ORM LED's high efficiency and precise lighting distribution delivers high illumination to Date Comments the surgical task area. Quality and value are maintained to provide the best performance solution for your design needs. Prepared by S PEC IFIC A TION FEA T U R E S.

2 Mounting G a s ke t Driver recessed grid or flange, ceiling Closed-cell silicone gasket seals Electronic, standard 0-10V. mount. Standard 1 or 1 1/2 door to housing. dimming. NEMA Type G ceiling systems. F i ni s h Co mplian ce Housing High gloss, electrostatically Die-formed, heavy gauge applied, white powder coat finish, MIL-STD-461F available with aluminum, powder coat painted average minimum reflectance 92%. standard drivers (ASY/SYM/RFI or white. Seam-welded construction, 89BC lens required) and filter(s). absent of holes. L e ns Results furnished upon request.

3 One-piece asymmetric/symmetric See Options for exact catalog Do o r acrylic lens. RFI 3/8 square nomenclature. Door is hinged to the housing with metalized grid, grounded to Labels two stainless steel aircraft cables. housing. Silicone gasket around the acrylic lens perimeter. Other ETL listed for wet location under ORM LED. Fas t e n e r s lenses available, refer to Ordering covered ceiling, non-IC rated. IP65. Captive stainless steel Philips head Information. rated. 2x2. 2x4. screws secure door frame to the 1x4. housing. L ED. LD4 LED. LEDs available in 3000K, 3500K.

4 healthcare : Operating room Do o r F r a m e and 4000K, and 5000k with CRI >. Cold rolled steel, painted white, 85. Projected life is 50,000 hours at flat inset door standard. Optional 70% lumen maintenance. brushed stainless steel, flat inset. recessed FLANGE. recessed GRID. Wet Location IP65 rated MIL-STD-461F. 23-11/16" 11-11/16". [602mm] [297mm]. 4-3/4" 4-3/4". [120mm] [120mm].. ORM-F 2x2/2x4 CROSS-SECTION ORM-F 1x4 CROSS-SECTION. 2x2 ceiling cut-out dimensions: 24" (W) x 24-5/16" (L) 1x4 ceiling cut-out 2x4 ceiling cut-out dimensions: 24" (W) x 48-5/16" (L) dimensions: 12" (W) x 48-5/16" (L).

5 23-11/16" 11-11/16". [602mm] [297mm]. 4-1/16" 4-1/16". [103mm] [103mm]. ORM-G 2x2/2x4 CROSS-SECTION ORM-G 1x4 CROSS-SECTION. PS519016EN. 2018-03-05 09:43:24. OR M LE D. ORDER ING INFOR M A TION. SAMPLE NUMBER: ORM-G-24-4-LD4-6-STD-40-277-ASY/SYM/RFI- EDC2. Product Ceiling No. of Illumination Color Door/Finish Family Type Width Length LED Level Temp. Voltage Lens Driver Circuits Options Options ORM LD4. ORM= Electronic Driver 2. Operating EDC_=Electronic Driver, Non-Dimming room / EDD_=Electronic Driver, Surgical Suite 0-10V Dimming 10%. ED1D_ =Electronic Driver, G=Grid (1" & 1-1/2" T-Bar) 0-10V Dimming 1%.

6 F=Flange (Swing-out brackets standard) 1= Single Circuit 3. 2= Two Circuits 3, 4. 24 =24" Wide 3= Three Circuits 3, 4. 12 =12" Wide 2=2' Length 4=4' Length Blank=Die-formed, cold rolled steel, white powder LD4=Linear LED, Version coat, flat inset door ALP=Die-formed Aluminum, white powder coat finish, 2=(2) LED Modules in cross-section (1' x 4' only). flat inset door. 3=(3) LED Modules in cross-section (1' x 4' only) SSP=Stainless Steel, white 4=(4) LED Modules in cross-section (2' x 2', 2' x 4') powder coat finish flat 6=(6) LED Modules in cross-section (2' x 2', 2' x 4') inset door.

7 SSN=Stainless Steel Brushed STD=Standard finish, flat inset door. LO=Low HI=High 8. (See table below). EL7W=7W EM Pack 3,7. 30=3000K EL10W=10W EM Pack 3,7. 35=3500K EL14W=14W EM Pack 3,7. 40=4000K AM=Anti-microbial finish (all painted parts). 50=5000K GRNF=Green Filter over outboard 2 LED Modules 120=120V MIL1=MILSTD 461F compliant, 277=277V one filter for single circuit 1, 3, 6, 8. MIL2=MILSTD 461F compliant, ASY/SYM=Asymmetric/Symmetric Lens, with Clear Acrylic two filters for dual circuits 1, 3, 6, 8. Lens Underlay, and .020 opal diffusing overlay 9 MIL3=MILSTD 461F compliant, ASY/SYM/RFI=Asymmetric/Symmetric Lens with RFI grid, with Clear three filters for three circuits 1, 3, 6, 8.

8 Acrylic Lens Underlay, and .020 opal diffusing overlay 1, 9 MSC4=Mounting Security Clips 10. A125=Pattern 12 acrylic, thick inverted 89BC= thick KSH19 RFI- Symmetrical, with Clear Acrylic Lens Underlay1. MICROLNRPRSM032/89BV=Acrylic, Linear Prismatic Pattern .032 , and Acrylic K12 RFI .125 , with Clear Acrylic Lens Underlay Accessories MSC4-PK=Mounting Security Clips. Use to secure fixture to grid or to attach tie-wires. 10. NOTES: DFCL-2448W-U*=2' x 4' gasketed drywall framing kit. Ships with 1 For MILSTD461F compliance, the ASY/SYM/RFI or 89BC lens is required.

9 Gasket to be applied in field. Cut out dimension x . 2 Default is (1) driver per (2) 2' nominal LED modules, (1) driver per (1) 4' nominal length LED module. DFCL-1248W-U*=1' x 4' gasketed drywall framing kit. Ships with 3 Each circuit requires a separate thermal protector. Thermal protector is installed along fixture side, approximately 2 inches gasket to be applied in field. Cut out dimension x . from bottom of fixture. Non-IC rated. See Thermal Protector Detail below. DFCL-2424W-U*=2' x 2' gasketed drywall framing kit. Ships with 4 For two circuits, outboard two LED modules on one circuit, all other LED modules on second circuit.

10 Gasket to be applied in field. Cut out dimension x . 5 For three circuits, outer-most two modules on one circuit, inner-most two modules on one circuit, remaining two modules on third circuit. *Change W to AMW for antimicrobial matte white finish 6 MILSTD requires factory-installed back-box on fixture top, which adds 2" to fixture height. 7 Emergency requires factory-installed back-box on fixture top, which adds 2" to fixture height. 8 1' x 4' with 3 LED modules in cross-section, 2' x 2' and 2' x 4' with 6 LED modules in cross-section, in combination with EBP.