PREFACEThis manual provides information necessary for maintenance of theFANUC Control MotorAmplifier series (servo amplifier units SVU and SVUC).There are two servo amplifier unit types, as listed ** The specification of this type is partly differentfrom that of the C series servo amplifier. Conforms to ** This type is designed to satisfy the compatibility with the C series servo amplifier. Does not conform to I describes the procedure to start up the servo amplifier unit. Part IIdescribes the error recovery procedure. Part III describes the cautions that should be observed in switching fromthe C series servo amplifier to the series servo amplifier unit SVU or document uses the abbreviations listed **SVUA06B-6090-H**SVUCFANUC Series FS- Fanuc Power Mate MODEL PM- In this manual, the servo parameter numbers are arranged as shown Function name or bit of the servo parameter No.

B–65195EN/01 START-UP PROCEDURE 2. CONFIGURATION 5 The basic configuration is shown below. Refer to “FANUC CONTROL MOTOR AMPLIFIER α Series (SERVO AMPLIFIER UNIT) Descriptions” (B-65192EN) for detail.

Tags:

  Fanuc

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fanuc Spares - Pennine Automation Spares Ltd

1 PREFACEThis manual provides information necessary for maintenance of theFANUC Control MotorAmplifier series (servo amplifier units SVU and SVUC).There are two servo amplifier unit types, as listed ** The specification of this type is partly differentfrom that of the C series servo amplifier. Conforms to ** This type is designed to satisfy the compatibility with the C series servo amplifier. Does not conform to I describes the procedure to start up the servo amplifier unit. Part IIdescribes the error recovery procedure. Part III describes the cautions that should be observed in switching fromthe C series servo amplifier to the series servo amplifier unit SVU or document uses the abbreviations listed **SVUA06B-6090-H**SVUCFANUC Series FS- Fanuc Power Mate MODEL PM- In this manual, the servo parameter numbers are arranged as shown Function name or bit of the servo parameter No.

2 1877 Overload protection coefficient (OVC1) FS-16, 18, 20, 21PM-D, F FS-0 CNo. 8X62No. 2062In addition to this manual, those listed below are provided for the FANUCC ontrol Motor Amplifier series (servo amplifier unit).1) Fanuc CONTROL MOTOR AMPLIFIER seriesSERVO AMPLIFIER UNIT DESCRIPTIONSB-65192EN2) Fanuc AC SERVO MOTOR series DESCRIPTIONSB-65142E3) Fanuc AC SERVO MOTOR series PARAMETER MANUALB-65150 EExamplesWhen maintaining or inspecting the servo amplifiers, keep thepower supply switched off. Also make sure that the CHARGING LED (red) beside thecircuit breaker on the front panel of the servo amplifier is off.(See Appendix A.)IMPORTANTB 65195EN/01 Table of contentsiI. START-UP PROCEDURE1. OVERVIEW3.. 2. CONFIGURATION4.. CONFIGURATION5.. COMPONENTS6.. 3. START-UP PROCEDURE8.. OF THE START-UP PROCEDURE9.

3 THE POWER SUPPLY10.. the Line Voltage and Power Requirements10.. to the Protection Ground10.. Current and Selecting a Ground Fault Interrupter10.. SETTING12.. THE BATTERY FOR AN ABSOLUTE PULSE CODER14.. THE SEPARATE REGENERATIVE DISCHARGE UNIT15.. SERVO PARAMETERS18.. 4. OPERATION CONFIRMATION METHOD25.. PROCEDURE26.. AMPLIFIER UNIT CHECK PINS27.. the +5V Power Supply Voltage27.. the Motor Instantaneous Current27.. INDICATOR29.. 5. AXIS LEFT UNUSED IN A MULTI-AXIS AMPLIFIER30.. 6. SERVO CHECK BOARD31.. II. TROUBLESHOOTING AND RECOVERY1. OVERVIEW37.. 2. ALARM NUMBER AND BRIEF DESCRIPTIONS38.. NUMBER IN SERIES 15 (SERVO ALARMS)39.. NUMBER IN SERIES 0-C (SERVO ALARMS)40.. NUMBER IN SERIES 16, 18, 20 (SERVO ALARMS)41.. 3. TROUBLESHOOTING AND RECOVERY PROCEDURES42.. AMPLIFIER UNIT43.

4 Indications and Meanings43.. to be Taken on Each Alarm44.. CONVERSION FAILURE ALARM48.. SOFTWARE49.. B 65195EN/01 Table of Adjustment Screen49.. Alarm50.. Disconnected Alarm50.. Overheat Alarm51.. Servo Parameter Setting Parameters51.. Coder Error Alarm57.. Speed Data Error Alarm57.. Coder Communication Error Alarm58.. 4. REPLACING THE FUSE59.. III. COMPATIBILITY OF THE SVU AND SVUC WITH THE C SERIES AMPLIFIER1. OVERVIEW63.. 2. COMPATIBILITY OF THE SVU AND SVUC WITH THE C SERIES AMPLIFIER64.. 3. SVUC SPECIFICATION CODE66.. APPENDIXA. SERVO AMPLIFIER UNIT FRONT PANEL69.. B. MOTOR GROUNDING CONNECTION70.. I. START-UP PROCEDUREB 65195EN/011. OVERVIEWSTART-UP PROCEDURE31 OVERVIEWThis part provides information necessary to confirm the systemconfiguration and start up the servo amplifier units : Configuration Start- up procedure Operation confirmation procedure2.

5 CONFIGURATIONB 65195EN/01 START-UP PROCEDURE42 CONFIGURATIONB 65195EN/012. CONFIGURATIONSTART-UP PROCEDURE5 The basic configuration is shown to Fanuc CONTROL MOTOR AMPLIFIER Series (SERVOAMPLIFIER UNIT) Descriptions (B-65192EN) for detail. Ex. Tow SVU2sPower Supply ForControl Circuit Servo AmplifierUnitSVU2 ServoAmplifierUnitSVU21 AC200/220/230V+10, 15%ACLineFilter3 (AC380V)(AC415V)(AC460V)AC200 VAC220 VAC230 VBreakerMagneticContactorServoMotorServo MotorServoMotorServoMotor(Note 1) (Note 2) (Note 3)PowerTransformer : Basic : Optional : Units prepared by the machine tool builderNotes1 This circuit breaker is intended to protect the power cord and related equipment. A circuitbreaker to protect a servo amplifier unit is provided within the servo amplifier This AC line filter should always be used,so influence by harmonic noise to the power supplycan be reduced.

6 When the line voltage is out of specification,and a power transformer (isolationtype) is used, the AC line filter can be omitted. If the AC line filter is ineffective in making the servo amplifier unit satisfy EMC standards, usean appropriate commercial noise The magnetic contactor is required if it is necessary to qualify for European CE When using the SVU,install a surge absorber between the power lines and between a powerline and a ground line at the entrance of the power magnetic cabinet in order to protect theequipment from a surge voltage. For the SVUC, it is unnecessary to install an external surgeabsorber because the SVUC has a built- in surge absorber as the C series CONFIGURATIONB 65195EN/01 START-UP PROCEDURE6(1) SVU 1 ModelOder specificationWiring boardspecificationP. C. (2) SVU 2 ModelOder specificationWiring boardspecificationP.

7 C. 65195EN/012. CONFIGURATIONSTART-UP PROCEDURE7(1) SVUC 1 ModelOder specificationWiring boardspecificationP. C. or laterSVUC1-12A06B-6090-H003A16B-2202-095 6/03B or laterSVUC1-40A06B-6090-H004A20B-2002-004 5A20B-2002-0031/03B or laterSVUC1-80A06B-6090-H006A20B-2002-004 7/03B or laterSVUC1-130A06B-6090-H008A20B-2002-00 55(2) SVUC 2 ModelOder specificationWiring boardspecificationP. C. or laterSVUC2-4/12A06B-6090-H223A20B-2002-0 152/03B or laterSVUC2-4/40A06B-6090-H224A20B-2002-0 153 SVUC2-12/12A06B-6090-H233A20B-2002-0154 SVUC2-12/40A06B-6090-H234A20B-2002-0155 SVUC2-12/80A06B-6090-H236A20B-2002-0156 SVUC2-40/40A06B-6090-H244A20B-2002-0157 SVUC2-40/80A06B-6090-H246A20B-2002-0158 SVUC2-80 START-UP PROCEDUREB 65195EN/01 START-UP PROCEDURE83ST T B 65195EN/013. START-UP PROCEDURESTART-UP PROCEDURE9 Start-up procedure1.

8 Confirm the CNC model, nd the specifications of the control motors, detectors, and servo amplifier Check for damage to the Confirm the line voltage and power requirements. (See Section )4. Connect the grounding line, power cords, and motor power wires. (See Section )5. Check the settings. (See Section )6. Start up the servo amplifier OF THESTART-UPPROCEDURE3. START-UP PROCEDUREB 65195EN/01 START-UP PROCEDURE10(1) Line voltgeBefore connecting the power source to the mchine, check the voltgeof the power input forpowerVoltage 200/220/230 VAC+10%, 15%Frequency 50Hz, 60Hz " 2 HzVoltage deviation due to load (at maximum output)shall be 7% or input forcontrol powerVoltage 200/220/230 VAC+10%, 15%Frequency 50Hz, 60Hz " 2 HzSingle-phase input forESP of SVUCV oltage 100 VAC +10%, 15%Frequency 50Hz " 2 HzORVoltage 100/110 VAC +10%, 15%Frequency 60Hz "2Hz)(2) Power requirements The power requirement of the servo amplifier unit is the sum of thepower requirements of individual servo motors.

9 When servo motor accelertes or decelertes rapidly, it may requirepower twice as much as the continuous rating momentarily. Check onthe input voltage required when more than one servo motor accelertesor decelertes simultaneously, and keep the voltage above 170 VAC. Refer to Chapter 5 of SERVO AMPLIFIER UNIT Descriptions (B-65192EN) for details of the power requirements.(3) When motor power and control power are input separately from eachother. When supplying motor power and control power separatelyfrom each other, be sure to remove a jumper connecting L1C and L1,and a jumper connecting L2C and L2. (These jumpers have beenfactory-insatlled.)When it is necessary to make a motor operating with the SVU qualify forEuropean CE marking, ground the motor using the accessory that installing more than one protection ground line with singlescrew makes it impossible for the motor to qualify for European CEmarking.

10 (See Appendix NO TAG.)Because the drive circuit for the servo amplifier unit operates by pulsewidth modulation control system using IGBTs, high-frequency leakagecurrent flows from the motor windings and power lines to the groundthrough stray capacitance. This leakage current may cause the groundfault interrupter or leakage protection relay installed in the power line onthe power supply side to malfunction. So they must have a maesureagainst influence from inverters so tht they do not THEPOWER the LineVoltage and to theProtection Current andSelecting a GroundFault InterrupterB 65195EN/013. START-UP PROCEDURESTART-UP PROCEDURE11(1) Leakage current from the motorDetermine the leakage current from each motor according to the modelLeakage current of commercial power frequency component to mA 12 to mA 30 to mA3.