Example: tourism industry

FAS 15 mm MICROSOL 3/2 MS Media separated solenoid valve

FAS 15 mm MICROSOL 3/2 MS Media separated solenoid valve 11/15en policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2015 - 5168a) 2015 Fluid Automation Systems :Neutral or aggressive gasesand liquidsOperation:Direct acting 3-way Media separated valvesOperating pressure:Orifice mm: bar ( psi) Orifice mm: ( psi)Flow:kv: l/min; flow: 24 l/min (orifice mm, at p = 2 bar, 20 C (+68 F) )kv: l/min; flow: 33 l/min (orifice mm, at p = 2 bar, 20 C (+68 F) ) Mounting:Manifold Orifice:1,2 and 1,6 mmLife expectancy: 10 Mio. cyclesWeight:30 g ( lbs)Ambient/ Media temperature:+5.

FAS 15 mm MICROSOL 3/2 MS Media separated solenoid valve 11/15 en 5.2.043.001 Our policy is one of continued research and development. We therefore reserve the right to amend, without

Tags:

  Microsol, Fas 15 mm microsol

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FAS 15 mm MICROSOL 3/2 MS Media separated solenoid valve

1 FAS 15 mm MICROSOL 3/2 MS Media separated solenoid valve 11/15en policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2015 - 5168a) 2015 Fluid Automation Systems :Neutral or aggressive gasesand liquidsOperation:Direct acting 3-way Media separated valvesOperating pressure:Orifice mm: bar ( psi) Orifice mm: ( psi)Flow:kv: l/min; flow: 24 l/min (orifice mm, at p = 2 bar, 20 C (+68 F) )kv: l/min; flow: 33 l/min (orifice mm, at p = 2 bar, 20 C (+68 F) ) Mounting:Manifold Orifice:1,2 and 1,6 mmLife expectancy: 10 Mio. cyclesWeight:30 g ( lbs)Ambient/ Media temperature:+5.

2 +50 C (+41 .. +122 F)Air supply must be dry enoughto avoid ice formation attemperatures below +2 C (+35 F). Technical featuresMaterials:Body in contact with Media : PEEKSeal and diaphragm material incontact with Media :FPM, FFPM, EPDM >3/2 UNI Media separated , Manifold mounting >Low internal volume, virtually no unswept volume >Large pressure rang >Long life - in excess of 10 Mio. cycles >Very compact design >Low power consumption 4/0,4 WElectrical detailsFollowing options on requestVoltage tolerance: 5%Voltage: 12 and 24 (>60ms)Power consumption: 4/0,4 WElectrical connectionAMP 2 PElectrical insulation:1500 class:F (155 C)Protection class: IP51 Cycle rate:< 4 HzIntegrated pulse width modulation (PWM) Revert polarity detectionOperating pressureMaterialsManual overrideCoil orientationVoltageElectrical connection (leads)Technical data - standard modelsSymbolOrifice(mm)Operating pressure(bar) (psi)Back pressure max.

3 *1)(bar) (psi)kv *2)(l/min)Voltage [V ]Power consumption *3) [W]Seal / DiaphragmMaterialModel322101210121012133 2133213310121012101213321332131, ,2-13,8 ..31,91,1015,950,8124/0,4 FPM01-333EF03-B1+23112+AXA1, ,2-13,8 ..31,91,1015,950,8124/0,4 EPDM01-333EF03-B5+23112+AXA1, ,2-13,8 ..31,91,1015,950,8124/0,4 FFPM01-333EF03-B6+23112+AXA1, ,2-13,8 ..31,91,1015,950,8244/0,4 FPM01-333EF03-B1+23112+AZU1, ,2-13,8 ..31,91,1015,950,8244/0,4 EPDM01-333EF03-B5+23112+AZU1, ,2-13,8 ..31,91,1015,950,8244/0,4 FFPM01-333EF03-B6+23112+AZU*1) Maximum back pressure during commutation: 50% of operating pressure *2) Cv = 0,07 kv *3) Power consumption: "boosting power during approx 50 ms" / "holding power"Embedded electronics optionsWithout integrated pulse width modulationFAS 15 mm MICROSOL 3/2 MS Media separated solenoid valveOur policy is one of continued research and development.

4 We therefore reserve the right to amend, without notice, the specifications given in this document. (2015 - 5168a) 2015 Fluid Automation Systems 11/15 Dimensions shown in mmProjection/First angleDimensionsMounting M5 manifold Model: Mounting screw2 Sealing area All solenoids are supplied with mounting screws and gasket. 3 valve mount threads WarningThese products are intended for use in neutral or aggressive gases and liquids only. Do not use these products where pressures and temperatures can exceed those listed under Technical features .Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult IMI misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

5 The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately Produkte sind ausschlie lich mit neutrale oder aggressive Gasen und Fl ssigkeiten zu verwenden. Sie sind dort einzusetzen, wo die unter Technische Merkmale aufgef hrten Werte nicht berschritten werden. Ber cksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte mit Fl ssigkeiten sowie bei nicht industriellen Anwendungen, in lebenserhaltenden- oder anderen Systemen, die nicht in den ver ffentlichten Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI Missbrauch, Verschlei oder St rungen k nnen in Pneumatik-systemen verwendete Komponenten auf verschiedene Arten wird dringend empfohlen, die St rungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu ber ck-sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um Verletzungen von Personen sowie Besch digungen der Ger te im Falle einer solchen St rung zu verhindern.

6 Systemausleger sind verpflichtet, Sicherheitshinweise f r den End-benutzer im Betriebshandbuch zu vermerken, wenn der St rungs-schutz nicht ausreichend gew hrleistet ist. AccessoriesElectrical connectionMounting manifold with M5 threads - 1 position, connector MPM 9,4 mm industry standard (C192) to mate AMP spade 2,8 x 0,5 connector Model: ,524,5123,525Pg7 153354,715,5 +0,1 15,5 +0,1 39,4+0,1 -127351541550 AMP 2,8 x 0,59,4M3 x 332121,527,611,610,54,6M2,5321210,5 0,1M53158 0,542,815M53,53,52721,5 0,1 Connecting area