FCQG-F/FCQHG-F/FXFQ-A Round flow cassette - …

ARGUE CARDS fcqg -F/ fcqhg -F/ fxfq -AWhy choose Round flow cassette ?t 360 air discharge for optimum efficiency and comfort in shops, offices and restaurantst Unique auto-cleaning panel Round flow cassetteBenefits for the installer Product with unique functions in the market Less time needed on site for maintenance Use the controller to individually open or close any of the four flaps to easily adapt to a changing room layout Easy set-up of the sensor option to improve comfortand save for the consultant Product with unique functions in the market Designed for use in all types and sizes of commercial offices andretail environments Ideal product to improve BREEAM score/EPDB in combinationwith Sky Air Seasonal Smart or VRV IV heat pump for the end user Designed for use in all types and sizes of commercial offices andretail environments Perfect environment conditions: no more cold draughtsor cold feet Save up to % on running costs with the auto-cleaning panel,which also facilitates maintenance Save up to % on your energy bill thanks to the sensor option Flexible usage of space thanks to individual flap functions that help saving costs Daikin was the first to launch a cassette using the roundflow principle with sensors* and a unique auto-cleaning panel*.

ARGUE CARDS FCQG-F/FCQHG-F/FXFQ-A Why choose Round flow cassette? t 360° air discharge for optimum efficiency and comfort in shops, offices and restaurants

Tags:

  Round, Cassette, Fcqg f fcqhg f fxfq, Fcqg, Fcqhg, Fxfq, Round flow cassette

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FCQG-F/FCQHG-F/FXFQ-A Round flow cassette - …

1 ARGUE CARDS fcqg -F/ fcqhg -F/ fxfq -AWhy choose Round flow cassette ?t 360 air discharge for optimum efficiency and comfort in shops, offices and restaurantst Unique auto-cleaning panel Round flow cassetteBenefits for the installer Product with unique functions in the market Less time needed on site for maintenance Use the controller to individually open or close any of the four flaps to easily adapt to a changing room layout Easy set-up of the sensor option to improve comfortand save for the consultant Product with unique functions in the market Designed for use in all types and sizes of commercial offices andretail environments Ideal product to improve BREEAM score/EPDB in combinationwith Sky Air Seasonal Smart or VRV IV heat pump for the end user Designed for use in all types and sizes of commercial offices andretail environments Perfect environment conditions: no more cold draughtsor cold feet Save up to % on running costs with the auto-cleaning panel,which also facilitates maintenance Save up to % on your energy bill thanks to the sensor option Flexible usage of space thanks to individual flap functions that help saving costs Daikin was the first to launch a cassette using the roundflow principle with sensors* and a unique auto-cleaning panel*.

2 Energy efficient as no other The auto-cleaning panel* means:- Running costs are reduced by % compared with standard solutions thanks to automatic daily filter cleaning- Less time is required to maintain the filter: dust can easily be removed with a vacuum cleaner without opening the unit Thanks to the presence and floor sensors* the unit changes its setpoint or switches off completely, if there are no people present in the room, resulting in energy savings of up to %.. And improved comfort air flow discharge pattern The presence sensor* directs the air away from anyone detected in the room The floor sensor* detects the average floor temperature and ensure an even temperature distribution between the ceiling and the floor. Cold feet are history!Flexible installation Flaps can be individually controlled or closed using the wired remote control, to suit room configuration. Optional closure kits are also Reference Wolverhampton, UK Running costs were reduced with up to 50% compared to standard solutions thanks to daily filter tools Visit the website: cleaning cassetteStandard Round flow cassetteCumulative energy comparison over monthsEnergy consumption (kWh)50% difference in electricity consumptionJuly Aug.

3 Sept. Oct. Nov. Dec. Jan. Feb. March April May June July * available as an 1686/02/2015 8:54:45 BRC E A-B, BRC FA FRXS-L fcqg - - FEfficiency dataFCQG + RXS* F + L F + L F + LCooling . /- . / . / .. / . / . Heating . /- . / . / .. / . / . Power .. Seasonal efficiency (according to EN ) CoolingEnergy labelA++A++PdesignkW .. SEER .. Annual energy consumptionkWh Heating (Average climate)Energy labelA++A++A+PdesignkW .. SCOP .. Annual energy consumptionkWh , , Nominal efficiencyEER .. COP .. Annual energy consumptionkWh Energy labelCoolingAAAH eatingBABI ndoor unitFCQG F F FDimensionsUnitHeightxWidthxDepthmm x x WeightUnitkg Decoration panelModelBYCQ D W / BYCQ D W W / BYCQ D GW ColourPure White (RAL )DimensionsHeightxWidthxDepthmm x x / x x / x x Weightkg . / . / . Air filterTypeResin net with mold resistanceFan - Air flow /min . / . / .. / . / .. /.

4 / . /min . / . / .. / . / .. / . / . Sound power level CoolingdBA HeatingdBA Sound pressure / / / / / / / / Power supplyPhase / Frequency / VoltageHz / V ~ / / - Control systemsInfrared remote controlBRC FA FWired remote controlBRC D / BRC E A/BOutdoor unitRXS* L L LDimensionsUnitHeightxWidthxDepthmm x x x x WeightUnitkg . Sound power level CoolingdBA HeatingdBA Sound pressure levelCoolingHigh/LowdBA-/- / / HeatingHigh/LowdBA-/- / / Operation rangeCoolingAmbientMin.~Max. CDB- ~ - ~ HeatingAmbientMin.~Max. CWB- ~ - ~ RefrigerantType/Charge/GWPkgR- A / - / , . R- A / . / , . R- A / . / , . ChargeTCO Eq- .. Piping connectionsLiquidODmm .. GasODmm .. Piping lengthOU - Additional refrigerant chargekg/m- . (for piping length exceeding m)Level differenceIU - . Power supplyPhase / Frequency / VoltageHz / V ~ / / - ~ / / - - Current - HzMaximum fuse amps (MFA)A--*Note: blue cells contain preliminary data ( ) EER/COP according to Eurovent , for use outside EU only ( ) Nominal efficiency: cooling at / nominal load, heating at / nominal loadFCQG-F + RXS-L3/LRound flow cassette air discharge for optimum efficiency and comfort Combination with split outdoor units is ideal for smaller applications such as retail or residential applications Daily automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs.

5 Two optional intelligent sensors improve energy efficiency and comfort. Individual flap control. Flexibility to suit every room layout without changing the location of the unit! Lowest installation height in the market: mm for class Modern style decoration panel is available in different variations: white (RAL ) with grey louvers, full white (RAL ) or auto cleaning panel Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump Fresh air intake integrated in the same system thus reducing installation cost as no additional ventilation is required Standard drain pump with mm lift increases flexibility and installation speed No optional adapter needed for DIII-connection, link your unit into the wider building management sensorfloor sensor 1696/02/2015 8:54:47