Transcription of FD ELECMAN 2016 CATALOG - fd-japan.com
1 Max. 30AW/FUSE, RED COVER2 Coils Normal Open Contact TypeTerminal :B BatteryS1, S2 Dimmer SW or Toggle SWL1, L2 Head Lamp or Fog & Driving LampS3 Positive Car : Ground, or Negative Car : Terminal BWiring DiagramMax. 20AW/FUSE, RED COVER2 Coils Normal Open Contact TypeTerminal :B BatteryS1, S2 Dimmer SW or Toggle SWL1, L2 Head Lamp or Fog & Driving LampS3 Positive Car : Ground, or Negative Car : Terminal BMax. 30AW/O FUSE, BLUE COVER2 Coils Normal Open Contact Type12 VSLR-12B12 VSLR-24B24 VRELAY SWITCHHEAD LIGHT RELAYT erminal ArrangementTerminal FUSE, BLUE COVER2 Coils Normal Open Contact TypeTerminal :B BatteryS1, S2 Dimmer SW or Toggle SWL1, L2 Head Lamp or Fog & Driving LampS3 Positive Car : Ground, or Negative Car : Terminal BWiring DiagramMax.
2 20AW/O FUSE, BLUE COVER2 Coils Normal Open Contact TypeTerminal :B BatteryS1, S2 Dimmer SW or Toggle SWL1, L2 Head Lamp or Fog & Driving LampS3 Positive Car : Ground, or Negative Car : Terminal BSLR-24D24V144 Break Max. 20A / Make Max. 40A1 Coil Change Over Contact for UniversalTerminal :B Battery through SwitchL1 Load 1 L2 Load 2C1(Round Male Plug Connection) SwitchC2(Round Female Plug Connection) GroundWiring DiagramBreak Max. 15A / Make Max. 30A1 Coil Change Over Contact for UniversalTerminal :B Battery through SwitchL1 Load 1 L2 Load 2C1(Round Male Plug Connection) SwitchC2(Round Female Plug Connection) GroundBreak Max. 30A / Make Max. 60 AWith Diode1 Coil Change Over Contact for connectionTerminal ArrangementSR04A-12C12 VRELAY SWITCHHEAVY DUTY RELAYSR05A-24 SPECIFICATIONS crew connectionTerminal ArrangementSR05A-1212V24 VWith Diode1 Coil Change Over Contact for UniversalW/Water proof skirtTerminal :B BatteryC1 GroundC2 SwitchL1 Load of Break SideL2 Load of Make SideAll Snap-on ConnectionWiring DiagramBreak Max.
3 25A / Make Max. 50 AWith Diode1 Coil Change Over Contact for UniversalW/Water proof skirtTerminal :B BatteryC1 GroundC2 SwitchL1 Load of Break SideL2 Load of Make SideAll Snap-on ConnectionConnector Ass'y for SR04A-12C, SR04A-24C RelayAttachment Female Termainal (7116-3250 x 3pcs.)(7116-2090 x 2pcs.)SR04A-24C24 VSR04A-601145 Break Max. 20A / Make Max. 40 ALIGHT YELLOW COVER1 Coil Change Over Contact for UniversalTerminal :B BatteryC1 GroundC2 SwitchL1 Load of Break SideL2 Load of Make SideAll Snap-on ConnectionWiring DiagramBreak Max. 15A / Make Max. 30 ALIGHT YELLOW COVER1 Coil Change Over Contact for UniversalTerminal :B BatteryC1 GroundC2 SwitchL1 Load of Break SideL2 Load of Make SideAll Snap-on ConnectionMax. 40 ALIGHT YELLOW COVER1 Coil Normal Open Contact for UniversalTerminal :B BatteryC1 GroundC2 SwitchL2 Load All Snap-on ConnectionWiring DiagramMax.
4 30 ALIGHT YELLOW COVER1 Coil Normal Open Contact for Universal Terminal :B BatteryC1 GroundC2 SwitchL2 Load All Snap-on Connection5 Female TerminalsConnector Ass'y for SRM, SRN SWITCHSUPER SMALL RELAYSRN-2424 VTerminal ArrangementTerminal ArrangementSPECIFICATION146 SRM-60-4500 SRM-1212V24 VSRM-24 SRN-1212 VBreak Max. 20A / Make Max. 40A1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirtTerminal :30 Battery85 Ground86 Switch87 Load of Make Side87a Load of Break SideWiring DiagramAll Snap-on ConnectionBreak Max. 15A / Make Max. 30A1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirtTerminal :30 Battery85 Ground86 Switch87 Load of Make Side87a Load of Break SideAll Snap-on ConnectionBreak Max. 20A / Make Max. 40 AWith Diode1 Coil Change Over Contact for SWITCHSUPER SMALL RELAYT erminal ArrangementTerminal ArrangementSPECIFICATIONWith Diode1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirtTerminal :30 Battery85 Ground86 Switch87 Load of Make Side87a Load of Break SideWiring DiagramAll Snap-on ConnectionBreak Max.
5 15A / Make Max. 30 AWith Diode1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirtTerminal :30 Battery85 Ground86 Switch87 Load of Make Side87a Load of Break SideAll Snap-on Connection5 Female TerminalsConnector Ass'y for SR01A-12/24 RelaySR01A-24C24 VSR01-5001147 Max. 20A1 Coil Normal Open Contact for UniversalTerminal :3 Battery1 Switch2 Ground5 Load All Snap-on ConnectionWiring DiagramMax. 15A1 Coil Normal Open Contact for Universal Terminal :3 Battery1 Switch2 Ground5 Load All Snap-on Connection12 VTerminal ArrangementSR02B-2424 VRELAY SWITCHSUPER SMALL RELAYSR02B-12SR07A-12SR07A-12C W/DIODER ated Current (Resistance Load)Break 10A Make 20AW/Water proof skirtTerminal :3 Battery1 Switch2 Ground4 Load of Breake Side5 Load of Make SideSR07A-24SR07A-24C W/DIODER ated Current (Resistance Load)Break 5A Make 10AW/Water proof skirtTerminal :3 Battery1 Switch2 Ground4 Load of Breake Side5 Load of Make SideSR07A-601 Attachment ConnectorConnector 1ea.
6 Female Terminal big size 2pcs. small size Wiring Diagram W/O DiodeGeneral Wiring Diagram W/Diode12 VTerminal ArrangementMICRO RELAY148On Delay Time : From second to 6 second adjustableON DELAY TIMER Terminal :B Battery (Blue Lead Wire)S Switch (Red Lead Wire)L1 Load of Break Side (White Lead Wire)L2 Load of Make Side (Yellow Lead Wire)E Ground (Black Lead Wire)Wiring DiagramOn Delay Time : From second to 6 second adjustableON DELAY TIMER Terminal :B Battery (Blue Lead Wire)S Switch (Red Lead Wire)L1 Load of Break Side (White Lead Wire)L2 Load of Make Side (Yellow Lead Wire)E Ground (Black Lead Wire)Off Delay Time : From second to 6 second adjustableOFF DELAY TIMER TR01-12TR04-1212 VTR01-2424 VRELAY SWITCHON / OFF DELAY TIMER ArrangementSPECIFICATIONT erminal Arrangement12 VBESL2L1BL1 OFF DELAY TIMER Terminal :B Battery (Red Lead Wire)S Switch (Blue Lead Wire)L1 Load of Break Side (White Lead Wire)L2 Load of Make Side (Yellow Lead Wire)E Ground (Black Lead Wire)(Note) Outside view will be DiagramOff Delay Time : From second to 6 second adjustableOFF DELAY TIMER Terminal.
7 B Battery (Red Lead Wire)S Switch (Blue Lead Wire)L1 Load of Break Side (White Lead Wire)L2 Load of Make Side (Yellow Lead Wire)E Ground (Black Lead Wire)(Note) Outside view will be COVERForTR01-12TR01-24TR03-12TR03-24SR02 -601TR04-2424 VBESL1L2149 RELAY SWITCHRELAY SWITCHRELAY SWITCHHAZARD WARNING AND HEAVY DUTY FLASHER RELAYHAZARD WARNING AND HEAVY DUTY FLASHER RELAYHAZARD WARNING AND HEAVY DUTY FLASHER DiagramFR-2424 VHeavy Duty Transistor type24V Flasher Relay25W 2 + 12W 13 +3W25W 2 + 12W 13 +3 WHazard Warning Max. 430W (24V 18A)Hazard Warning Max. 430W (24V 18A) FR-24 Connection of Terminal FR-24 Connection of TerminalL (Blue Wire : Male Terminal) To Lamp through Flasher SwitchL (Blue Wire : Male Terminal) To Lamp through Flasher SwitchB (Red Wire : Male Terminal) To Main Switch through FuseB (Red Wire : Male Terminal) To Main Switch through FuseE (Black Wire : Spade type Terminal) To GroundE (Black Wire : Spade type Terminal) To Ground Note on Use Note on Use1.
8 This relay is only for 24V Minus Ground car and is used both as Hazard Warning and Flasher This relay is only for 24V Minus Ground car and is used both as Hazard Warning and Flasher Make sure not to install this relay at outside of Make sure not to install this relay at outside of Installation and removal of this relay should be done after turnoff of main Installation and removal of this relay should be done after turnoff of main When flashing unstableness and noise occur , change B (Red) wire for4. When flashing unstableness and noise occur , change B (Red) wire for AV or AVS wire more than 2m from place close to the battery. AV or AVS wire more than 2m from place close to the battery. MINI BLADE FUSE HOLDERMINI BLADE FUSE HOLDERMINI BLADE FUSE Connection Use is Connection Use is possible.
9 Two AVS 2m Red Wires are attached. Two AVS 2m Red Wires are attached. Fuse(Max. 20A) is not installed. Fuse(Max. 20A) is not installed. This holder is of waterproof. This holder is of waterproof. In case of double connection use, fix the In case of double connection use, fix the Single Use holders to the real machine by vinyl band. Double Connection Use Single Use holders to the real machine by vinyl band. Double Connection Use150150 Max. 120A (Within 30 seconds)2 Holes Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) BatteryM (Screw Connection) StarterWiring DiagramS (Red Wire Male Terminal) Starter SwitchMax. 120A (Within 30 seconds)1 Hole Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) BatteryM (Screw Connection) StarterWiring DiagramS (Red Wire Male Terminal) Starter SwitchMax.
10 60A (Within 30 seconds)2 Holes Stay TypeRELAY SWITCHSTARTER ArrangementTerminal ArrangementTerminal Arrangement2 Holes Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) BatteryM (Screw Connection) StarterWiring DiagramS1 (White Stripe on Black Wire Male Terminal) SwitchS2 (Black Wire Female Terminal) GroundMax. 60A (Within 30 seconds)1 Hole Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) BatteryM (Screw Connection) StarterS1 (White Stripe on Black Wire Male Terminal) SwitchWiring DiagramS2 (Black Wire Female Terminal) GroundSS090B24 VTerminal Arrangement151 Rated Current 80A (Continuous)2 Holes Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) BatteryM (Screw Connection) StarterWiring DiagramS (Red Wire Male Terminal) Starter SwitchJIDECO NO.