Example: tourism industry

FEATURES & SPECIFICATIONS - Acuity Brands …

OUTDOOR TFR-M-SCatalog NumberNotesType*Weight as configured in example dimensions are inches (centimeters) unless otherwise halide200M1250M2400M2 High pressure sodium3150S250S400 STA (7 X 6)4RB(6 X 6)RC(5 X 5)120208524 052773474805TB623050HZ7(blank)Magnetic ballastCWIC onstant wattage isolated7 SCWAS uper SCWA pulse start ballastNote: For shipments to territories, SCWA must be specified to comply with installed(blank)Yo keISIntegral slipfitter (2-3/8" OD tenon) Shipped separately8,9 EYExtended yoke10 FRWBR adius wall bracket11 FSABS teel angle bracket10 FSPBS teel square pole bracket11 FTST enon slipfitter (2-3/8" to 2-7/8" OD tenon)10 FWPBWood mounting bracket10 OptionsFinish16 Lamp18 Shipped installed in fixtureSFSingle fuse (120, 277, 347V)12 DFDouble fuse (208, 240, 480V)

OUTDOOR TFR-M-S Catalog Number Notes Type *Weight as configured in example below. All dimensions are inches (centimeters) unless otherwise specified.

Tags:

  Feature, Catalog, Specification, Brand, Acuity, Features amp specifications, Acuity brands

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FEATURES & SPECIFICATIONS - Acuity Brands …

1 OUTDOOR TFR-M-SCatalog NumberNotesType*Weight as configured in example dimensions are inches (centimeters) unless otherwise halide200M1250M2400M2 High pressure sodium3150S250S400 STA (7 X 6)4RB(6 X 6)RC(5 X 5)120208524 052773474805TB623050HZ7(blank)Magnetic ballastCWIC onstant wattage isolated7 SCWAS uper SCWA pulse start ballastNote: For shipments to territories, SCWA must be specified to comply with installed(blank)Yo keISIntegral slipfitter (2-3/8" OD tenon) Shipped separately8,9 EYExtended yoke10 FRWBR adius wall bracket11 FSABS teel angle bracket10 FSPBS teel square pole bracket11 FTST enon slipfitter (2-3/8" to 2-7/8" OD tenon)10 FWPBWood mounting bracket10 OptionsFinish16 Lamp18 Shipped installed in fixtureSFSingle fuse (120, 277, 347V)12 DFDouble fuse (208, 240, 480V)

2 12 ECEmergency circuit13 QRSQ uartz restrike system13 PERNEMA twist-lock photoelec-tric receptacle14C622' 16-3 SEO cord prewiredC422' 14-3 SEO cord prewiredC222' 12-3 SEO cord prewiredCFCharcoal filterCSAL isted and labeled to comply with CSA standardsNOM NOM Certified7 INTLA vailable for MH probe start shipping outside the Title 20 effective 1/1/2010 Shipped separately8 WGWire guard9,15 VGVandal guard9,15 UVUpper visor9,15 FVFull visor9,15PE1 NEMA twist-lock photocontrol (120, 208, 24 0V)PE3 NEMA twist-lock photocontrol (347V)PE4 NEMA twist-lock photocontrol (480V)PE7 NEMA twist-lock photocontrol (277V)SCShorting cap for PER option(blank)Dark bronzeDNAN atural aluminumDBLB lackDMBM edium bronzeDWHW hiteCRTNon-stick protective coating17 Super durable finishesDDBXDDark bronzeDBLXDB lackDNAXDN atural aluminumDWHXDW hiteDDBTXDT extured dark bronzeDBLBXDT extured blackDNATXDT extured natural aluminumDWHGXDT extured whiteLPILamp includedL/LPLess lampORDERING INFORMATIONE xample: TFR 400M TA TB SCWA LPIFor shortest lead times, configure product using standard options (shown in bold).

3 FloodlightingTFRMETAL HALIDE: 200W - 400 WHIGH PRESSURE SODIUM: 150W - 400 WSpecificationsHeight: 10-1/2 ( )Width: 17-5/8 ( )Depth: 12-3/4 ( )*Weight: 27 lbs ( kg)EPA: & SPECIFICATIONSINTENDED USE For recreation areas, parking lots, building facades, car NEMA heavy-duty construction. Contoured, low-profile die-cast aluminum housing and front bezel. Front bezel is hinged for easy removal via position-oriented hinge-cam design. Sealed by a one piece bonded high-temperature silicone : Impact-resistant, thermal-and shock-resistant clear tempered glass. Finish: Standard finish is dark bronze (DDB) corrosion resistant polyester powder. With additional archi-tectural Anodized aluminum reflector provides highly efficient rectangular beam pattern.

4 Optic chamber sealed to inhibit entrance of outside Ballast: High pressure sodium: 150W is high reactance, high power factor. Constant wattage autotransformer for 200-400W. Metal halide: 150W is high reactance, high power factor and is standard with pulse-start ignitor technology. "SCWA" not required. Super CWA (pulse start ballast), DOE 2017 compliant, is required for metal halide 200-400W (SCWA option) for US shipments only. CSA, NOM or INTL required for probe start shipments outside of the US. Pulse-start ballast (SCWA) required for 200W. Ballast is 100% factory-tested. Socket: Porcelain, horizontally-oriented, mogul-base socket with copper alloy, nickel plated screw shell and center contact. UL Listed 1500W, 600V, 4KV pulse Corrosion-resistant, heavy-duty, painted steel mounting yoke standard; die-cast inte-gral tenon slipfitter optional.

5 All external slotted hex-head screws specially coated for Listed and labeled to UL standards. Listed and labeled to CSA standards (see Options). NOM Certified (see Options). UL Listed for 25 C ambient; 40 C for 250M and below or 150S and below. UL Listed for wet location. IP65 1-year limited warranty. Complete warranty terms located at : Actual performance may differ as a result of end-user environment and application. SPECIFICATIONS subject to change without Must order These wattages require the REGC1 option to be chosen for shipments into California for Title 20 compliance. 250M REGC1 in not available in 347 or 480V. 3. Not available with Not available with Must specify CWI for use in Canada. 6. Optional multi-tap ballast (120, 208, 240, 277V).

6 In Canada 120, 277, 347V; ships as 120 Consult factory for available May be ordered as an Must specify finish when ordered as an accessory. 10. Yoke mounting only. 11. Requires IS or FTS Must specify voltage. Not available with Maximum allowable wattage lamp Photocell not Prefix with TFR when ordered as an accessory. Field modification required unless ordered with See for additional color Black finish Must specify. L/LP not available with MHC. 17-5/8( )12-3/4( )10-3/4( ) TFR-M-S OUTDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-279-8041 1989-2017 Acuity Brands Lighting, Inc.

7 All rights reserved. Rev. 02/09/17 TFR FloodlightCartesian PlotAngle (Deg)-90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90 0140028004200560070008400980011200126001 4000 Max - 0 Max - - - - - - - in Units of Mounting HeightClassification: Unclassified (Type NC, Very Short), CutoffMounting Height = 20 Intensity1/2 Maximum IntensityHouse SideStreet SideDistance in Units of Mounting HeightISOILLUMINANCE PLOT (FC) PlotAngle (Deg)-90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90 0420084001260016800210002520029400336003 780042000 Max - 0 Max - -2 Max - -2 Max - -2 Max - -2 Max - -2 Max - -2 Max - -2 IntensityDistance in Units of Mounting HeightClassification: Unclassified (Type I, Very Short), CutoffMounting Height = 20 Intensity1/2 Maximum IntensityHouse SideStreet SideDistance in Units of Mounting HeightISOILLUMINANCE PLOT (FC) 400M TA, 400W pulse start metal halide lamp, 40,000 rated lumens, test no.

8 1197100301 PTFR 400M RC, 400W pulse startmetal halide lamp, 40,000 rated lumens, test no. 1197082602 PMounting Height Correction Factor(Multiply the fc level by the correction factor)15 ft. = ft. = .6430 ft. = .44 Notes1 Photometric data for other distributions can be accessed at Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and SPECIFICATIONS on this sheet based on the most current available data and are subject to change without For electrical characteristics, consult outdoor technical data specification sheets on Actual performance may differ as a result of end-user environment and application.