Example: dental hygienist

Federal Pacific Medium Voltage Transformer Catalog

Federal Pacific Medium Voltage Transformer Catalog Federal Pacific History In 1987, Electro-Mechanical Corporation acquired the dry-type Transformer division of Federal Pacific Electric in Des Plaines, Illinois. It was moved to Bristol, Virginia and the name was changed to Federal Pacific (FP). A new 100,000. square foot facility was constructed where time- proven designs and modern technology were combined and deployed under new management. Expansion in early 1993 provided an additional 36,000 square feet of manufacturing space. Federal Pacific Today Federal Pacific is a major manufacturer of dry- type transformers which serve the industrial, construction, commercial, mining, OEM and utility markets. The product scope is 50 VA.

impedance voltage and the amount of losses (excluding no-load losses) in the transformer when carrying full rated load. These losses consist primarily of I2R losses in the primary and secondary winding and ensure that specifications of the transformer design are met. Excitation Current Testing determines the current necessary

Tags:

  Transformers, Winding, Impedance

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Federal Pacific Medium Voltage Transformer Catalog

1 Federal Pacific Medium Voltage Transformer Catalog Federal Pacific History In 1987, Electro-Mechanical Corporation acquired the dry-type Transformer division of Federal Pacific Electric in Des Plaines, Illinois. It was moved to Bristol, Virginia and the name was changed to Federal Pacific (FP). A new 100,000. square foot facility was constructed where time- proven designs and modern technology were combined and deployed under new management. Expansion in early 1993 provided an additional 36,000 square feet of manufacturing space. Federal Pacific Today Federal Pacific is a major manufacturer of dry- type transformers which serve the industrial, construction, commercial, mining, OEM and utility markets. The product scope is 50 VA.

2 Through 10,000 kVA and 120 volts through 25,000. volts. The 600 volt class offering includes industrial control transformers , encapsulated/. compound-filled general purpose and buck- boost transformers , ventilated designs for general purpose applications, electrostatically shielded transformers and a complete line of motor drive isolation transformers . The Medium Voltage offering includes core and coil transformers , general purpose designs, pad mount transformers , unit substation transformers , vacuum pressure impregnated transformers (VPI), and VPI/epoxy shielded transformers . K-Factor rated transformers are offered for the entire product scope. Distribution Regional warehouse stocks have been implemented across the United States, ensuring quick delivery anywhere in the country.

3 2. Table of Contents Medium Voltage 4-8. High Voltage General Purpose 9-11. Unit Substation Style 12-16. Pad-Mounted 17. High-Rise Building 18. Motor Drive Isolation 19. ABS Type 20. Upgrade, Refurbish / KVA Upgrade, Voltage 21. Transformer 22. Transformer Selection 23-26. Advantages of Ventilated Dry-Type Medium Voltage Over Liquid 27. Advantages of VPI Epoxy Shield Compared to Cast 28. Unit Substation Style (USST) Transformer Specification 29-30. 31-34. Dimensions in this Catalog not to be used for construction purposes. Consult factory for detailed construction drawings. 3. Medium Voltage Dry-Type transformers Overview Insulation System Federal Paci c is an industry leader in providing custom Federal Pacific transformers utilize a 220 C insulation system engineered dry-type transformers for low and Medium that combines inorganic materials and resins to provide a Voltage applications.

4 Designs are available in a wide re resistant, high dielectric capability. All materials have variety of types and ratings to provide reliable and versatile been thoroughly tested and proven with respect to their electrical distribution for lighting and power loads in stability at required operating temperatures. industrial and commercial applications. Whether the application requires a dedicated use, engineered design The major components of the 220 C system include Nomex . or a commonly-used Transformer with a simple Voltage paper for conductor insulation plus resin-glass laminates, transformation for special equipment, Federal Paci c can silicon rubber and polyester varnish. The combination of design and build your Transformer quickly and reliably.

5 Materials is speci cally chosen to assure long operating life and quiet operations Federal Paci c offers a full line of Medium Voltage transformers . Base styles and ratings are shown below. Nomex is a Registered Trademark of Dupont Co. These transformers can be configured to meet most any Industry Standards & Certi cations application requirement. All Medium Voltage transformers are engineered-to-order to the requested specifications. Federal Paci c dry-type transformers are UL Listed and are designed, tested, and manufactured in accordance with High Voltage General Purpose transformers applicable industry standards of ANSI, NEMA and IEEE. to 15kV, 15kVA through 1500kVA. Unit Substation transformers Industry-Leading Ship Times through 25kV, 15kVA through 10 MVA Under the Lightning Fast Program Federal Paci c can deliver engineered-to-order low and Medium Voltage transformers Pad-Mounted transformers with significantly reduced lead time (additional charges through 25kV, 15kVA through 10 MVA apply).

6 Lightning Fast shipments should be requested at the time of quotation as some designs may be exempt from The air-cooled, dry-type construction requires no special the service. vault for installation. Units may be located in almost any indoor location convenient to the load being served. Most Medium Voltage Typical Shipment Lead Times transformers are also available for outdoor installations. Standard Lightning Fast Maintenance requires only periodic inspection of cable kVA Lead Time Lead Time connections and removal of any dust accumulation. 500 4-6 Weeks 2 Weeks Special Applications 750 4-6 Weeks 3 Weeks Below are a few examples of the many variations of 1000 4-6 Weeks 4 Weeks specialty transformers Federal Paci c has designed and manufactured.

7 Special sound levels Test transformers Reconnectables Mine Duty Multiple primaries/secondaries ABS Marine Duty Special impedance Drive Isolation Auto- transformers Plus many others Special Paint 4. Medium Voltage Dry-Type transformers Standard Tested Performance Sound Levels Federal Paci c performs a standard series of tests to ensure Federal Paci c transformers are designed, built, and comply proper operation, adherence to applicable standards and with NEMA and IEEE maximum sound level requirements. product quality. Tests performed include: Medium Voltage Sound Levels and Typical impedance Ratio Testing is performed on rated Voltage connection In accordance with IEEE and tap connections to assure the proper turns ratio on all Percent impedance - 3 Phase Audible Sound Levels (db) - 3 Phase Forced Air connections.

8 KVA 5 kV Class 15kV Class Self Cooled Cooled (FA). (30 kV BIL) (60 kV BIL) (AA) Average Average Polarity Test and Phase Relation Tests are made to ensure Consult Factory Consult Factory 50 . proper polarity and marking because of their importance in 150 Consult Factory Consult Factory 50 . paralleling or banking two or more transformers . 225 Consult Factory Consult Factory 55 . No-load (Excitation) Loss Testing determines the losses of a 300 55 67. Transformer which is excited at rated Voltage and frequency, 500 60 67. but which is not supplying a load. Transformer excitation 750 64 67. losses consist mainly of losses in the core of the Transformer . 1000 64 68. impedance Voltage & Load Loss Test determines the 1500 65 69.

9 impedance Voltage and the amount of losses (excluding no- 2000 66 71. load losses) in the Transformer when carrying full rated load. 2500 68 71. These losses consist primarily of I2R losses in the primary 3000 68 73. and secondary winding and ensure that specifications of >3000 Consult Factory Consult Factory Consult Factory Consult Factory the Transformer design are met. Excitation Current Testing determines the current necessary to maintain Transformer excitation. Resistance Testing is performed on the Transformer windings and is used to determine I2R loss. Dielectric Tests (applied and induced potential) check the insulation and workmanship to demonstrate that the Transformer has been designed and manufactured to meet the insulation levels required by the standards and/or customer.

10 Applied Potential Testing is performed by impressing a low frequency Voltage between windings and between each winding and ground. Induced Potential Tests over-excite the Transformer by applying between the terminals on one winding a Voltage of twice the normal Voltage developed in the winding for a period of 7200 cycles. 5. Medium Voltage Dry-Type transformers The United States Department of Energy (DOE) establishes energy efficiency standards for all transformers under DOE. Article 10 CFR 431. The latest updates to the standards went into effect on January 1, 2016. Federal Pacific 's transformers meet the requirement set forth by the Department of Energy. The established standards and efficiency requirements have been defined below.


Related search queries