Example: biology

Fiberglass Door - Florida Approval FL8228

BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL8228 -R7 Application TypeAffirmationCode Version2014 Application Status Approved CommentsArchived Product ManufacturerMasonite InternationalAddress/Phone/Email1955 Powis Road West Chicago, IL 60185 (615) 441-4258 Authorized SignatureSteve Schreiber Technical RepresentativeAddress/Phone/Email Quality Assurance RepresentativeAddress/Phone/Email CategoryExterior DoorsSubcategorySwinging Exterior Door Assemblies Compliance MethodCertification Mark or Listing Certification AgencyNational Accreditation & Management InstituteValidated ByNational Accreditation & Management Institute, Referenced St

May 05, 2015 · Installation Instructions FL8228_R7_II_FL0160Dx.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL8228_R7_AE_502A.pdf Created by Independent Third Party: Yes 8228.4 Fiberglass Side-Hinged Door Unit 6'-8" Opaque Outswing Single or Double Door w/ or w/o Sidelites Limits of Use

Tags:

  Installation, Fiberglass, Instructions, Doors, Installation instructions, Approval, 2288fl, Fiberglass doors, Approval fl8228

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fiberglass Door - Florida Approval FL8228

1 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL8228 -R7 Application TypeAffirmationCode Version2014 Application Status Approved CommentsArchived Product ManufacturerMasonite InternationalAddress/Phone/Email1955 Powis Road West Chicago, IL 60185 (615) 441-4258 Authorized SignatureSteve Schreiber Technical RepresentativeAddress/Phone/Email Quality Assurance RepresentativeAddress/Phone/Email CategoryExterior DoorsSubcategorySwinging Exterior Door Assemblies Compliance MethodCertification Mark or Listing Certification AgencyNational Accreditation & Management InstituteValidated ByNational Accreditation & Management Institute, Referenced Standard and Year (of Standard)

2 StandardYearASTM E18862002 ASTM E19962002 ASTM E3302002 TAS 2021994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my Building Code which affect my product(s) and my product(s) are in compliance with the new Florida product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation EntityYesYesNoNoN/AN/APage 1 of 5 Florida Building Code Online5/5/2015 Product Approval MethodMethod 1 Option A Date Submitted04/29/2015 Date Validated04/29/2015 Date Pending FBC ApprovalDate Approved05/04/2015 Summary of ProductsFL #Model, Number or Side-Hinged Door Unit6'-8" Opaque I/S and O/S Single DoorLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: + Other.

3 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0160-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit8'-0" Opaque I/S and O/S Single DoorLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: + Other.

4 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0161-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit6'-8" Opaque Inswing Single or Double Door w/or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: + Other.

5 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0160-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit6'-8" Opaque Outswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: + Other.

6 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0160-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit8'-0" Opaque Inswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Certification Agency Certificate Page 2 of 5 Florida Building Code Online5/5/2015 Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure.

7 + Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0161-07 for additional Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit8'-0" Opaque Outswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: + Other.

8 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not required in the Wind Borne Debris Region. See DWG-MA-FL0161-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit6'-8" Glazed Inswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: + Other.

9 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0162-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit6'-8" Glazed Outswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: + Other.

10 Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0162-07 for additional Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 installation instructions Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Side-Hinged Door Unit8'-0" Glazed Inswing Single or Double Door w/ or w/o SidelitesLimits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: + Other.