Example: confidence

filtration technologies ILTRATION STANDARD …

filtration technologiesULTRAFILTRATION STANDARDSYSTEMSC ompact solutions for superb water quality2filtration technologiesultrafiltration STANDARD systemsProduct Flow Rateof 30 to 720 m3/hFluytec s Ultrafiltration Systems are based on outside-in flow configuration ultrafiltration modules, which allow for less plugging, higher solids loading, higher flow area and easy cleaning. The primary flow design is dead-end filtration which uses less energy and has a lower operating pressure than the concentrate bleed, therefore reducing operating costs. Our STANDARD systems are designed for reliable, long term trouble free operation, with straight forward ConstructionWelded Frame: Painted and Blasting Carbon SteelDilute Piping: PVC-U / PPConcentrate Piping: PVC-U / PPFlanges: DINV alves: Plastic Coated Iron CastPower Panel Control: IP55 InstrumentationFlow: Raw Water (Feed) / OptionalPressure: Feed Inlet, Filtrate (Pr)

filtration technologies 3 ultrafiltration standard systems Quality Assurance Stainless Steel and GRP frames. Removal of PLC and HMI, all wiring

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of filtration technologies ILTRATION STANDARD …

1 filtration technologiesULTRAFILTRATION STANDARDSYSTEMSC ompact solutions for superb water quality2filtration technologiesultrafiltration STANDARD systemsProduct Flow Rateof 30 to 720 m3/hFluytec s Ultrafiltration Systems are based on outside-in flow configuration ultrafiltration modules, which allow for less plugging, higher solids loading, higher flow area and easy cleaning. The primary flow design is dead-end filtration which uses less energy and has a lower operating pressure than the concentrate bleed, therefore reducing operating costs. Our STANDARD systems are designed for reliable, long term trouble free operation, with straight forward ConstructionWelded Frame: Painted and Blasting Carbon SteelDilute Piping: PVC-U / PPConcentrate Piping: PVC-U / PPFlanges: DINV alves: Plastic Coated Iron CastPower Panel Control: IP55 InstrumentationFlow: Raw Water (Feed) / OptionalPressure: Feed Inlet, Filtrate (Product) OutletTurbidity.

2 Filtrate (Product) Outlet / OptionalTypicalMaximumTurbidity, NTU < 50300 TSS, mg/l< 50100 TOC, mg/l< 1040 COD, mg/l60Cl2 Continuous, , mg/l0< 2pH Continuous6-92-11 Temperature, C 2540 Operating ParametersFiltrate (Product) SDI (Product) Turbidity N T URecovery90 - 95%Temperature1 to 40 CMax. Feed Pressure (@ 20 C)6 barMax. Operating barEstimated Power Consumption< kWh/m Input Voltage400 VAC/3/50 HzFluytec UF Skid Features Solutions for virtually all water and wastewater treatment applications, such as surface water, seawater, industrial wastewaters and secondary effluent wastewater. Factory programmed PLC and color Panel HMI, allowing simple and highly automated operation.

3 Modular building-block design. System design to fit into ISO shipping containers. Compact footprint with flexible layout options. Simplified start up with minimal installation time. Reduced on-site construction costs with less interconnecting requirements. Quick delivery with complete engineering package. Full Operation & Maintenance Manual. Pneumatically actuated Water Requirements3filtration technologiesultrafiltration STANDARD systemsQuality Assurance Stainless Steel and GRP frames. Removal of PLC and HMI, all wiring terminated at a IP55 Junction Box. Supply of UF Feed Pump. Supply of Backwash & CIP Systems.

4 Supply of Fuytec s automated pre-screen. PE or GRP : CE MarkedFacility: ISO 9001:2000 Full Factory Acceptance Test (FAT) completed on each systembefore shipmentUltrafiltration STANDARD SystemsMODELFSUP-6 FSUP-20 FSUP-50 FSUP-72 FSUP-136 General InformationNumber of UF Modules6205072136 Flow RatesProduct Flow Nominal33 m3/h145 gpm110 m3/h485 gpm275 m3/h1,210 gpm400 m3/h1,760 gpm750 m3/h3,300 gpmFeed Flow32 m3/h141 m3/h566 gpm257 m3/h1,131 gpm385 m3/h1,695 gpm769 m3/h3,386 gpmWaste Backwash m3/h7 m3/h30 m3/h60 gpm20 m3/h88 m3/h173 gpmWaste Flush Forward m3/h2 m3/h8 m3/h15 m3/h22 m3/h44 gpmDimensionsEstimated System Dimensions*(Width x Length x Height) m1.

5 9 3 .1 m1. 9 x17. 8 x 3 .4 mFeed Inlet PipingDN80DN150DN250DN300DN450 Product Outlet PipingDN80DN150DN250DN300DN450 Backwash Inlet PipingDN100DN200DN250DN350DN500 Backwash Outlet PipingDN100DN200DN250DN350DN500 Forward Flush Outlet PipingDN50DN80DN150DN200DN200* Top header shipped loose to ease , flow rate per module, recovery and power consumption are dependent on inlet feed water quality and temperature. A projection must be completed for proper system design & for any performance guarantee to be to change without Sakoni, 18 48950 Erandio, Vizcaya (Spain) | T: (+34) 944 676 150 | | solutions worldwideVisit our Website for more information FTAUR series filters (Automatic Backwash Filters) FTP series cartridge filters (GRP).