Example: tourism industry

Find additional EPA Method 8000 Series Standards online at ...

241E-MAIL VISIT gu i d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO Method 8000 seriesepa Method 8000 seriesISO GUIDE 34 CERTIFIED REFERENCE MATERIALR eference Materials for Monitoring organic Pollutants in Ground WaterThe 8000 Series methods are used for monitoring organic pollutants in ground water as prescribed in the Resource Conservation and Recovery Act (see 40 CFR 264). These methods may be found in EPA publication SW-846, Test methods for Evaluating Solid Scientific has prepared a Series of reference Standards for the 8000 Series methods , as well as the necessary surrogate, internal, and calibration Standards . Each component in a reference standard is pre-analyzed, with most analytes being >99% pure, and the solvents are of the highest quality available. All solutions are gravimetrically prepared to a precision of A Level II ISO Guide 34 Reference Material Certificate of Analysis is available for each additional EPA Method 8000 Series Standards online at Method PAGE epa Method 8010b 242 epa Method 8011 243 epa Method 8015C 243 epa Method 8021C 244 epa Method 8020a 245 epa Method 8021b 246 epa Method 8030a 248 epa Method 8031, 8032a, 8033 248 epa Method 8041a 249 epa Method 8061a 251 epa Method 8070a 252 epa Method 8080a 252 epa m

246 Toll free 800.338.1754 main 401.294.9400 fax 401.295.2330 epa m e TH od 8021 b iso g u i de 34 FOR ASE ONTACT ULTRA O .ULTRASCI.COM HalogenaTed and aromaTiC VolaTile organiCs Method 8021B is used to determine aromatic and halogenated …

Tags:

  Methods, Aromatic, Organic, Volatile, M e th od, Aromatic volatile organics method

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Find additional EPA Method 8000 Series Standards online at ...

1 241E-MAIL VISIT gu i d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO Method 8000 seriesepa Method 8000 seriesISO GUIDE 34 CERTIFIED REFERENCE MATERIALR eference Materials for Monitoring organic Pollutants in Ground WaterThe 8000 Series methods are used for monitoring organic pollutants in ground water as prescribed in the Resource Conservation and Recovery Act (see 40 CFR 264). These methods may be found in EPA publication SW-846, Test methods for Evaluating Solid Scientific has prepared a Series of reference Standards for the 8000 Series methods , as well as the necessary surrogate, internal, and calibration Standards . Each component in a reference standard is pre-analyzed, with most analytes being >99% pure, and the solvents are of the highest quality available. All solutions are gravimetrically prepared to a precision of A Level II ISO Guide 34 Reference Material Certificate of Analysis is available for each additional EPA Method 8000 Series Standards online at Method PAGE epa Method 8010b 242 epa Method 8011 243 epa Method 8015C 243 epa Method 8021C 244 epa Method 8020a 245 epa Method 8021b 246 epa Method 8030a 248 epa Method 8031, 8032a, 8033 248 epa Method 8041a 249 epa Method 8061a 251 epa Method 8070a 252 epa Method 8080a 252 epa Method 8081b 254 epa Method 8082a 256 epa Method 8091 257 epa Method 8095 257 EPA Method PAGE epa Method 8100 258 epa Method 8121 259 epa Method 8141b 260 epa Method 8150b.

2 8151a 262 epa Method 8240b 264 epa Method 8260b 266 epa Method 8270d 270 epa Method 8280b & 8290a 294 epa Method 8310 295 epa Method 8315a 296 epa Method 8318a 296 epa Method 8330a 297 epa Method 8332 298 epa Method 8410 298 epa Method 8440 298242 TOLL FREE main FAX gu i d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO Method 8010bVolaTile HaloCarbonsMethod 8010B is used to determine volatile halogenated organic pollutants, using either purge and trap or direct injection, and an electrolytic conductiv-ity (Hall) 8010B has been deleted from SW-846 (effective with Update III).To read the complete Method , log onto our website at StandardsCalibration Standards : HCM-801-1 HC-070-1 HC-491-1 Surrogate Standard: STM-401-1 TeCHniCal noTe2-Chloroethyl vinyl ether is stable in solution by itself, but breaks down in the presence of other halocarbons.

3 Therefore ULTRA packages this analyte as a single component solution. If you prepare a working standard that contains 2-chloroethyl vinyl ether mixed with other halocarbons, be sure to monitor the stability of this Method 8010B Chloroprene Solutionchloroprene (no xylenes)@ 100 g/mL in methanolHC-491-1 1 x 1 mL Recommended Method 8010B Internal & Surrogate Standard Mix3 Analytes4-bromochlorobenzenebromochlorom ethane4-bromofluorobenzene@ 1500 g/mL in methanolSTM-401-1 1 x 1 mL Recommended Method 8010B 2-Chloroethyl Vinyl Ether Standards2-chloroethyl vinyl ether@ 100 g/mL in methanolHC-070-1 1 x 1 mL @ 5000 g/mL in methanolEPA-1016-1 1 x 1 mL VOC Gas Mixtures6 Analytesbromomethanechloroethanechlorome thanedichlorodifluoromethanetrichloroflu oromethanevinyl chloride@ 200 g/mL in methanolDWM-584-1 1 x 1 mL @ 2000 g/mL in methanolDWM-544-1 1 x 1 mL epa Method 8010bRecommended Method 8010B Halogenated Volatiles Mixture IX36 Analytesallyl chloridebromodichloromethanebromoformbro momethanecarbon tetrachloridechlorobenzenechloroethanech loroformchloromethane1,2-dibromo-3-chlor opropane1,2-dibromoethane1,2-dichloroben zene1.

4 3-dichlorobenzene1,4-dichlorobenzene1,1- dichloroethane1,2-dichloroethane1,1-dich loroethene1,2-dichloropropanecis-1,3-dic hloropropenetrans-1,3-dichloropropenedib romochloromethanedibromomethanedichlorod ifluoromethanemethylene chloridemethyl iodide1,1,1,2-tetrachloroethane1,1,2,2-t etrachloroethanetetrachloroethene1,1,1-t richloroethane1,1,2-trichloroethanetrans -1,2-dichloroethenetrans-1,4-dichloro-2- butenetrichloroethenetrichlorofluorometh ane1,2,3-trichloropropanevinyl chloride@ 100 g/mL in methanolHCM-801-1 1 x 1 mL IX Contains Appendix IX Compounds243E-MAIL VISIT gu i d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO and dibromoCHloropropaneMethod 8011 is used to determine 1,2-dibromoethane and 1,2-dibro-mo-3-chloropropane, using microex-traction, and capillary column GC with an read the complete Method , log onto our website at StandardsCalibration Standard: DWM-504N-1 HCM-812-1 Recommended Method 8011 Mixtures IX2 Analytes1,2-dibromo-3-chloropropane1,2-d ibromoethane@ 200 g/mL in methanolDWM-504N-1 1 x 1 mL @ 2000 g/mL in methanolHCM-812-1 1 x 1 mL IX Contains Appendix IX Compoundsnon-HalogenaTed organiCs Method 8015C is used to determine volatile nonhalogenated organics, using either purge and trap or direct injection, and a flame ionization detector (FID).

5 To read the complete Method , log onto our website at StandardsCalibration Standard: NVM-8015A-1 NVM-8015B-1 Internal Standard: STM-580-1 Recommended Method 8015C Calibration Standard18 Analytesacetoneacetonitrileallyl alcohol1-butanol (n-butyl alcohol)2-butanone (MEK)diethyl ether1,4-dioxaneethanolethyl acetateethylene glycolisobutyl alcohol (2-methyl-1-propanol)isopropyl alcohol (2-propanol)methanol4-methyl-2-pentanone (MIBK)2-pentanone1-propanol (n-propyl alcohol)propionitriletert-butyl alcohol (2-methyl-2-propanol)@ 2000 g/mL in waterNVM-8015A-1 1 x 1 mL Recommended Method 8015C Calibration Standard4 Analytes2-picolineN-nitrosodi-n-butylami neo-toluidinepyridine@ 2000 g/mL in methanolNVM-8015B-1 1 x 1 mL GRO aromatic Calibration Mix5 Analytesn-decane (C10)n-heptane (C7)n-hexane (C6)n-nonane (C9)n-octane (C8)@ 2000 g/mL in methanolSAK-100-1 1 x 1 mL Recommended Method 8015C Internal Standard Mixture3 Analytes2-chloroacrylonitrilehexafluoro- 2-propanolhexafluoro-2-methyl-2-propanol @ 2000 g/mL in waterSTM-580-1 1 x 1 mL epa Method 8011epa Method 8015 Cepa Method 8011, 8015C244 TOLL FREE main FAX Method 8021 CISO Gu I d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO Volatiles Mixture IX4 Analytes2-butanone (MEK)diethyl etherethyl alcohol4-methyl-2-pentanone (MIBK)@ 2000 g/mL in methanolNVM-8115-1 1 x 1 mL Non-Halogenated Volatiles Mixture IX12 Analytesacetonitrileacrylamide2-butanone (MEK)diethyl ether1,4-dioxaneethyl alcoholethyl methacrylateisobutyl alcoholmethacrylonitrilemethyl methacrylate4-methyl-2-pentanone (MIBK)propionitrile@ 100 g/mL in methanolNVM-8015-1 1 x 1 mL DRO Mixture10 Analytesn-decane (C10)

6 N-docosane (C22)n-dodecane (C12)n-eicosane (C20)n-hexacosane (C26)n-hexadecane (C16)n-octacosane (C28)n-octadecane (C18)n-tetracosane (C24)n-tetradecane (C14)@ 2000 g/mL in methylene chlorideUST-200-1 1 x 1 mL IX Contains Appendix IX CompoundsIX Contains Appendix IX Compoundsepa Method 8021 CVolume discounts for individual solutionsOrder 4 19 ampules of the same item and receive a 20% DISCOUNTO rder 20 or more ampules of the same item and receive a 30% DISCOUNTO rdering is Friday250 Smith Street8:30 - 5:00 ETNo. Kingstown, RI 02852245E-MAIL VISIT Method 8020aISO Gu I d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO VolaTiles Method 8020A is used to determine vol-atile aromatic organic compounds, using either purge and trap or direct injection, and a 8020A has been deleted from SW-846 (effective with Update III).To read the complete Method , log onto our website at StandardsCalibration Standard: AMM-802-1 Internal and Surrogate Standard.

7 STM-510-1 Recommended Method 8020A aromatic Volatiles Mixture IX11 Analytesbenzenechlorobenzene1,2-dichloro benzene1,3-dichlorobenzene1,4-dichlorobe nzeneethylbenzeneo-xylenem-xylenep-xylen estyrenetoluene@ 100 g/mL in methanolAMM-802-1 1 x 1 mL Recommended Method 8020A Internal and Surrogate Standard Mixture5 Analytes4-bromochlorobenzene4-bromofluor obenzene1,4-difluorobenzenefluorobenzene alpha,alpha,alpha-trifluorotoluene@ 1500 g/mL in methanolSTM-510-1 1 x 1 mL Surrogate Standard Mixture3 Analytes4-bromochlorobenzene1,4-difluoro benzenefluorobenzene@ 2000 g/mL in methanolSTM-420-1 1 x 1 mL Surrogate Standard Mixture2 Analytes4-bromofluorobenzenealpha,alpha, alpha-trifluorotoluene@ 2000 g/mL in methanolSTM-410-1 1 x 1 mL aromatic Volatiles Mixture IX10 Analytesbenzenechlorobenzene1,2-dichloro benzene1,3-dichlorobenzene1,4-dichlorobe nzeneethylbenzeneo-xylenem-xylenep-xylen etoluene@ 2000 g/mL in methanolAMM-812-1 1 x 1 mL PVOC Mixture7 Analytesbenzeneethylbenzenemethyl tert-butyl ether (MTBE)o-xylenem-xylenep-xylenetoluene@ 1000 g/mL in methanolUST-141-1 1 x 1 mL Methyl tert-Butyl Ether Solutionmethyl tert-butyl ether (MTBE)

8 @ 2000 g/mL in methanolSTS-440-1 1 x 1 mL Internal and Surrogate Standardalpha,alpha,alpha-trifluorotolue ne @ 200 g/mL in methanolSTS-221-1 1 x 1 mL @ 2000 g/mL in methanolSTS-220N-1 1 x 1 mL epa Method 8020aIX Contains Appendix IX CompoundsIX Contains Appendix IX Compounds246 TOLL FREE main FAX Method 8021bISO Gu I d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO and aromatic volatile organiCsMethod 8021B is used to determine aromatic and halogenated volatiles, using either purge and trap, headspace, vacuum distillation, or direct injection. Detection is carried out with a PID and ELCD in read the complete Method , log onto our website at StandardsCalibration Standards : DWM-588-1 HCM-822A-1 HC-070-1 HC-491-1 Surrogate Standard: STM-431-1 Internal Standard: STM-240N-1 TeCHniCal noTe2-Chloroethyl vinyl ether is stable in solution by itself, but breaks down in the presence of other halocarbons.

9 Therefore ULTRA packages this analyte as a single component solution. If you prepare a working standard that contains 2-chloroethyl vinyl ether mixed with other halocarbons, be sure to monitor the stability of this Method 8021B KitKit contains six ampules:1 x 1 mL of each of the following standardsVOC Mixture (DWM-588-1)Halogenated Volatiles Mix (HCM-822-1)Chloroethyl Vinyl Ether Soln. (HC-070-1)Chloroprene Solution (HC-491-1)Surrogate Standard Mix (STM-431-1)Internal Standard Mix (STM-240N-1)AMK-8021 Kit benzenebromobenzenebromochloromethanebro modichloromethanebromoformbromomethaneca rbon tetrachloridechlorobenzenechloroethanech loroformchloromethane2-chlorotoluene4-ch lorotoluene1,2-dichlorobenzene1,3-dichlo robenzene1,4-dichlorobenzene1,1-dichloro ethane1,2-dichloroethane1,1-dichloroethe necis-1,2-dichloroethenetrans-1,2-dichlo roethene1,2-dichloropropane1,3-dichlorop ropane2,2-dichloropropane1,1-dichloropro penecis-1,3-dichloropropenetrans-1,3-dic hloropropene1,2-dibromo-3-chloropro-pane dibromochloromethanedibromomethane1,2-di bromoethanedichlorodifluoromethaneethylb enzenehexachlorobutadieneisopropylbenzen e4-isopropyltoluenemethylene chloriden-butylbenzenen-propylbenzenenap hthaleneo-xylenem-xylenep-xylenesec-buty lbenzenestyrenetert-butylbenzene1,1,1,2- tetrachloroethane1,1,2,2-tetrachloroetha netetrachloroethenetoluene1,2,3-trichlor obenzene1,2.

10 4-trichlorobenzene1,1,1-trichloroethane1 ,1,2-trichloroethanetrichloroethene1,2,3 -trichloropropanetrichlorofluoromethane1 ,2,4-trimethylbenzene1,3,5-trimethylbenz enevinyl chlorideRecommended Method 8021B VOC Mixtures60 Analytes@ 200 g/mL in methanolDWM-580-1 1 x 1 mL @ 2000 g/mL in methanolDWM-588-1 1 x 1 mL Recommended Method 8021B Halogenated Volatiles Mixture6 Analytes1,3-dichloro-2-propanol2-chloroe thanolallyl chloridebenzyl chloridebis(2-chloroisopropyl) etherchloromethyl methyl ether@ 2000 g/mL in methanolHCM-822A-1 1 x 1 mL Recommended Method 8021B additional Analyte Standards2-chloroethyl vinyl ether@ 100 g/mL in methanolHC-070-1 1 x 1 mL @ 5000 g/mL in methanolEPA-1016-1 1 x 1 mL epa Method 8021b(continued on next page)247E-MAIL VISIT Method 8021bISO Gu I d e 34 FOR PRICING PLEASE CONTACT ULTRA SCIENTIFIC OR GO TO tetrachloridechlorobenzenechloroform2-ch lorotoluene4-chlorotoluenedibromochlorom ethane1,2-dibromo-3-chloropro-pane1,2-di bromoethanedibromomethane1,2-dichloroben zene1,3-dichlorobenzene1,4-dichlorobenze ne1,1-dichloroethane1,2-dichloroethane1, 1-dichloroethenecis-1,2-dichloroethenetr ans-1,2-dichloroethene1,2-dichloropropan e1,3-dichloropropane2,2-dichloropropane1 ,1-dichloropropenecis-1,3-dichloropropen etrans-1,3-dichloropropeneethylbenzenehe xachlorobutadieneisopropylbenzene4-isopr opyltoluenemethylene chloridenaphthalenen-propylbenzenestyren e1,1,1,2-tetrachloroethane1,1,2,2-tetrac hloroethanetetrachloroethenetoluene1,2,3 -trichlorobenzene1,2,4-trichlorobenzene1 ,1,1-trichloroethane1,1,2-trichloroethan etrichloroethene1,2,3-trichloropropane1, 2.