Fire Alarm System Inspection Check List - FPOA

fire Alarm System Inspection Check List The purpose of this checklist is to give the inspector a quick and easy guideline to follow when he or she is conducting a final Inspection of a newly installed fire Alarm System . Inspection Date: _____ Inspector: _____ Manufacture of fire Alarm System : _____ fire Alarm System Model Number: _____ Type of fire Alarm System Single Stage Two Stage Third Party fire Alarm Verification Report Received? Yes No N/A fire Alarm Monitored? Yes No N/A fire Alarm Monitoring Company. Yes No N/A Special Devices Connected to fire Alarm System fire Doors equipped with magnetic hold open devises Yes No N/A Commercial Cooking shut off devise Yes No N/A Roll down doors or shutters Yes No N/A Voice Communication System Yes No N/A Visual Check the Following Devices and Displays If a No is indicated below note the problem to the right Main fire Alarm Panel Zones properly indicated and marked YesNo Devices properly indicated and marked YesNo Power indicator lamp operational YesNo Panel clear from trouble indicators YesNo Lamp test YesNo Annunciator Panel Panel in an acceptable location YesNo Panel lamp

Fire Alarm System Inspection Check List The purpose of this checklist is to give the inspector a quick and easy guideline to follow when he or she is conducting a final inspection of a newly installed Fire Alarm System.

Tags:

  System, Lists, Fire, Inspection, Check, Lamar, Fire alarm systems, Fire alarm system inspection check list fpoa, Fpoa, Fire alarm system inspection check list

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fire Alarm System Inspection Check List - FPOA

1 fire Alarm System Inspection Check List The purpose of this checklist is to give the inspector a quick and easy guideline to follow when he or she is conducting a final Inspection of a newly installed fire Alarm System . Inspection Date: _____ Inspector: _____ Manufacture of fire Alarm System : _____ fire Alarm System Model Number: _____ Type of fire Alarm System Single Stage Two Stage Third Party fire Alarm Verification Report Received? Yes No N/A fire Alarm Monitored? Yes No N/A fire Alarm Monitoring Company. Yes No N/A Special Devices Connected to fire Alarm System fire Doors equipped with magnetic hold open devises Yes No N/A Commercial Cooking shut off devise Yes No N/A Roll down doors or shutters Yes No N/A Voice Communication System Yes No N/A Visual Check the Following Devices and Displays If a No is indicated below note the problem to the right Main fire Alarm Panel Zones properly indicated and marked YesNo Devices properly indicated and marked YesNo Power indicator lamp operational YesNo Panel clear from trouble indicators YesNo Lamp test YesNo Annunciator Panel Panel in an acceptable location YesNo Panel lamp test ok YesNo Power on lamp on YesNo Pull Station locations acceptable YesNo Heat Detectors and/or Smoke Detectors locations

2 Acceptable YesNo fire Alarm System Demonstration Notify fire Department of the fire Alarm Test. Include the address and how long the test should last. Have dispatch contact you when they receive the notification of alarms activated from the monitoring company. If a No is indicated below note the problem to the right fire location lamp on main panel operated correctly YesNo Bells and buzzers operated correctly YesNo Bells and Buzzers Audibility YesNo Monitoring company notified fire Station YesNo Annunciator Panel Indicated Proper Zone or location. YesNo System back on line No problems indicated on panels YesNo