Example: bankruptcy

Fire Detection Control Panel BC216-1

1 fire Detection Control PanelBC216-1 User Manual - Part CParameter setup - Maintenance2 Contents1 Symbols and type Important notes42 Parameter setup by means of Control Panel Using the PC Function Editing Other Main menu point [Parameter settings] Parameter setup of the global settings of the Control Panel - [Global settings] Parameter setup of the function modules - [Function modules] Parameter setup of a conventional detector interface Parameter setup of a loop interface Basic possibilities of parameter setup for the Control Panel Output Signal Parameter setup of the fire brigade interface - [FWI2-1] Parameter setup of the fire brigade interface - relay outputs - [FWI relay outputs] Parameter setup of the national version of the fire brigade Control unit [FBC]

6 2 Parameter setup by means of control panel keypad The parameter setup establishes the system-specific functions of the fire detection control panel.

Tags:

  Control, Fire, Panels, Detection, Control panels, Fire detection control panel

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Fire Detection Control Panel BC216-1

1 1 fire Detection Control PanelBC216-1 User Manual - Part CParameter setup - Maintenance2 Contents1 Symbols and type Important notes42 Parameter setup by means of Control Panel Using the PC Function Editing Other Main menu point [Parameter settings] Parameter setup of the global settings of the Control Panel - [Global settings] Parameter setup of the function modules - [Function modules] Parameter setup of a conventional detector interface Parameter setup of a loop interface Basic possibilities of parameter setup for the Control Panel Output Signal Parameter setup of the fire brigade interface - [FWI2-1] Parameter setup of the fire brigade interface - relay outputs - [FWI relay outputs] Parameter setup of the national version of the fire brigade Control unit [FBCU country version] Parameter setup of the fire brigade interface inputs [FWI inputs]

2 Parameter setup of the fire brigade interface open collector outputs [FWI oc-outputs] Parameter setup of the auxiliary outputs and of the siren output - [NTB outputs] Parameter setup of the LED-display field LAB48-1 - [LAB48-1] Parameter setup of the detector zones - [Zone settings] Parameter setup of actuations [Actuation settings] Parameter setup of transmitting devices - [Transm. device set.] Parameter setup of alarming devices [Alarming device set.] Parameter setup of the interfaces - [Interfaces] Automatic setup of the System configuration - [AUTO-setup] Description of logic Logic combinations for transmitting devices and alarming Logic combinations for actuations and actuation Entering logic Standard parameter setup with Settings print-out453 Parameter setup by means of PC and software Installation of the parameter setup software Functions of the parameter setup software Menu File management - menu point [File]

3 Data transfer - menu point Communication Check settings and project information - menu point Project Arrange windows - menu point Window Information - menu point Info Configuration window (system tree) Parameter setup Information Typical parameter setup process with PARSOFT-1524 Maintenance, Checking the final charge Checking the stand-by Earth leakage Function Maintenance support for loop Maintenance support on the Maintenance support on the Replacement of an ADM- or Loading a new software version Lost installer code5841 GeneralThe present third part of the User Manual (Part C)

4 Of the fire Detection Control Panel BC216-1 providesthe competent installer with the information necessary for parameter setup and maintenance of the controlpanel. This part of the manual is directly based on Part A and B of the User Manual. The determinations,remarks and explanations provided there will not be repeated in the present part of the manual. It is thereforeindispensable that you familiarise yourself with the contents of Part A and B of the User Manual beforestarting parameter setup and maintenance Symbols and type fontsParticularly important text passages of this manual are marked with symbols as in Part A.

5 The followingsymbols are used:Means DANGER! Failure to observe the instructions may threaten life and ATTENTION! Failure to observe the instructions may lead to malfunctioning of the systemor damage to TIP! The text passage contains descriptive information facilitating the operation of the firedetection Control Panel and adds to better understanding of the that the country- and/or site-specific demands of the approvals of the fire Detection controlpanel must be points and LC-display contents within the descriptive text are enclosed with brackets, ,[Alarms].

6 In overview presentations the display text will be presented in special font without Important notesFire Detection systems and devices must always be planned, installed and commissioned by trained specific training for the functions of the fire Detection Control Panel BC216-1 must be providedby Security House Export (SHE) or by persons expressly authorised by SHE for this to opening the case, switch off the mains voltage and secure to prevent switching on!Please note that with the case open, components are exposed which carry dangerous voltages withthe mains switched on!

7 The protective cover of these components must not be working on the fire Detection Control Panel and when handling componentries, observe theusual protective measures for the discharge of static charges: Before and during the work to be performedon the circuit boards it is necessary to reliably discharge static charges of the body by contactingan earth-connected metallic part. It is indispensable for mains-operated tools ( , solderingiron) to be connected with protective earth or expressly approved for use on static sensitive usual protective insulation is not installation, maintenance and reconditioning, observe the applicable laws, standards andguidelines for the installation and maintenance of fire alarm systems!

8 For all levels of parameter setup written in this part of the User Manual it is presupposed that the controlpanel has been completely connected corresponding to the information of the User Manuals SeriesBC216 / Part A and Part B and is working keep in mind that incorrectly entered parameters or incorrectly connected devices may lead to unin-tentional activation of system parts while doing commissioning and parameter setup jobs or during theconcluding test activities. Thereby, severe damage to property ( , by activating an extinguishing system)may result, emergency personnel may be alarmed or other undesired actuation procedures may beactivated.

9 Therefore, reliably disable all parts ( , by disconnecting the actuation line), which can causedamage by inattendent activation during commissioning of the fire Detection system. Make sure that thesedisabled parts are not re-enabled without your prior consent. Nevertheless, do not forget to re-enable thedisabled parts after ensuring the proper functioning of all system parts when finishing Parameter setup by means of Control Panel keypadThe parameter setup establishes the system-specific functions of the fire Detection Control Panel .

10 Themanifold possibilities offered by this Control Panel conversely require the definition of a very large numberof parameters. You establish all parameters by means of a clear menu Control . The menu Control itselfis described in detail in User Manual Series BC216 / Part HintsThis chapter describes the parameter setup of the fire Detection Control Panel at the technological level ofthe operating software with version number PL149 (the version number of the software is displayedin the menu [System] - [Hardware components], see User Manual Series BC216 / Part A).


Related search queries