Example: bankruptcy

Fisher 3582 and 3582i Positioners and 582i Electro ...

3582 and 3582i Positioners , 582iElectro pneumatic Converter, and 3583 ValveStem Position of Number Area Classifications and SpecialInstructions for Safe Use and Installationin Hazardous Areas for 582i Cam Connections for 3582iValve Converter positioner Cam Stem Position Transmitter (continued on page 2)Figure 1. Typical Mounting for Fisher 3582 and 3582i Positioners and 3583 TransmittersCONTROL VALVE WITH3582i POSITIONERCONTROL VALVE WITH3583 TRANSMITTERCONTROL VALVE WITH3582 POSITIONERW5498 1W8424W5499 1 Instruction ManualD200138X0123582, 582i, and 3583 August 2017 Instruction ManualD200138X0123582, 582i, and 3583 August 20172 Contents (cont'd)Valve positioner Bypass Signal positioner Split Range Valve positioner Valve Stem Position Of Valve positioner OrValve Stem Position of Valve Valve Valve Stem Position the Range the Nozzle O the the Flapper the 582i ConverterPrimary O Ring and the 582i Converter HousingCap O the 582i the 582i of ManualThis instruction manual includes installation, operation, calibration, maintenance, and parts ordering information forFisher 3582 pneumatic valve posit

This instruction manual includes installation, operation, calibration, maintenance, and parts ordering information for Fisher 3582 pneumatic valve positioners and the 3582i electropneumatic valve positioner. Refer to separate instruction manuals for information on the control valve, actuator, and accessories.

Tags:

  Manual, Pneumatic, Electro, Positioner

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fisher 3582 and 3582i Positioners and 582i Electro ...

1 3582 and 3582i Positioners , 582iElectro pneumatic Converter, and 3583 ValveStem Position of Number Area Classifications and SpecialInstructions for Safe Use and Installationin Hazardous Areas for 582i Cam Connections for 3582iValve Converter positioner Cam Stem Position Transmitter (continued on page 2)Figure 1. Typical Mounting for Fisher 3582 and 3582i Positioners and 3583 TransmittersCONTROL VALVE WITH3582i POSITIONERCONTROL VALVE WITH3583 TRANSMITTERCONTROL VALVE WITH3582 POSITIONERW5498 1W8424W5499 1 Instruction ManualD200138X0123582, 582i, and 3583 August 2017 Instruction ManualD200138X0123582, 582i, and 3583 August 20172 Contents (cont'd)Valve positioner Bypass Signal positioner Split Range Valve positioner Valve Stem Position Of Valve positioner OrValve Stem Position of Valve Valve Valve Stem Position the Range the Nozzle O the the Flapper the 582i ConverterPrimary O Ring and the 582i Converter HousingCap O the 582i the 582i of ManualThis instruction manual includes installation, operation, calibration, maintenance, and parts ordering information forFisher 3582 pneumatic valve Positioners , the 3582i Electro pneumatic valve positioner , and 3583 pneumatic valvestem position transmitters.

2 Refer to separate instruction manuals for information on the control valve, actuator, not install, operate or maintain a 3582 pneumatic valve positioner , a 3582i Electro pneumatic valve positioner , or a3583 pneumatic valve stem position transmitter without being fully trained and qualified in valve, actuator andaccessory installation, operation and maintenance. To avoid personal injury or property damage it is important tocarefully read, understand, and follow all of the contents of this manual , including all safety cautions and warnings. Ifyou have any questions about these instructions, contact your Emerson sales office or Local Business Partner pneumatic valve Positioners and the 3582i Electro pneumatic valve positioner shown in figure 1 are used withdiaphragm actuated, sliding stem control valve assemblies.

3 The pneumatic valve Positioners receive a pneumaticinput signal from a control device and modulate the supply pressure to the control valve actuator. The positioneradjusts the actuator supply pressure to maintain a valve stem position proportional to the pneumatic input Positioners are designed for nuclear power applications. The 3582NS construction includes materials thatprovide superior performance at elevated temperature and radiation levels. The O rings are EPDM (ethylenepropylene) and the diaphragms are EPDM/meta aramid fabric. EPDM demonstrates superior temperature capabilityand shelf life over nitrile. The meta aramid diaphragm fabric demonstrates improved strength retention at elevatedtemperature and radiation a clean, dry, oil free air supply with instruments containing EPDM components.

4 EPDM is subject to degradation whenexposed to petroleum based ManualD200138X0123582, 582i, and 3583 August 20173 Table 1. Specifications for Fisher 3582 and 3582i Valve PositionersNote: Specifications for 3582 Positioners include3582A, 3582C, 3582D, 3582G, and 3582NS unlessotherwise indicatedInput Signal3582 to bar (3 to 15 psig), to bar(6 to 30 psig), or Jsplit range, see table 103582i: 4 to 20 mA DC constant current with 30 VDCmaximum compliance voltage, can be split range, seetable 10 Equivalent Circuit for 3582iThe 582i converter equivalent circuit is 120 ohms,shunted by three volt zener diodes (see figure 10)Output SignalType: pneumatic pressure as required by actuator upto 95 percent of maximum supplyAction: Field reversible between Jdirect andJreverse within the pneumatic valve positionerSupply Pressure(1)Recommended: bar (5 psi) above actuatorrequirementMaximum.

5 Bar (50 psig) or pressure rating ofactuator, whichever is lowerSupply Medium: Air or Natural GasSupply medium must be clean, dry, and noncorrosivePer ISA Standard maximum 40 micrometer particle size in the airsystem is acceptable. Further filtration down to 5micrometer particle size is recommended. Lubricantcontent is not to exceed 1 ppm weight (w/w) orvolume (v/v) basis. Condensation in the air supplyshould be minimizedPer ISO 8573-1 Maximum particle density size: Class 7 Oil content: Class 3 Pressure Dew Point: Class 3 or at least 10_C less thanthe lowest ambient temperature expectedNote: The 3582i is not approved for use with naturalgas as the supply mediumInput Bellows Pressure Rating(1)See table 9 for minimum and maximum pressureratings (allowable input signal) for each availablerange springMaximum Steady State Air Consumption(2) bar (20 psig) Supply: normal m3/hr ( scfh) bar (30 psig) Supply: normal m3/hr ( scfh) bar (35 psig) Supply: normal m3/hr ( scfh) bar (20 psig) Supply: normal m3/hr ( scfh) bar (30 psig) Supply: normal m3/hr ( scfh) bar (35 psig) Supply.

6 Normal m3/hr ( scfh)Maximum Supply Air bar (20 psig) Supply: normal m3/hr ( scfh) bar (30 psig) Supply: normal m3/hr ( scfh) bar (35 psig) Supply: normal m3/hr ( scfh)Performance3582 Independent Linearity: 1 percent of output signalspanHysteresis: percent of span3582iIndependent Linearity: 2 percent of output signalspanHysteresis: percent of spanElectromagnetic Compatibility for 582ielectro pneumatic converterMeets EN 61326 1:2013 Immunity Industrial locations per Table 2 of the EN 61326 1 standard. Performance is shown in table 3 below. Emissions Class A ISM equipment rating: Group 1, Class ANote: The electromagnetic compatibilityspecifications also apply to the 3582i3582 and 3582iTypical Open Loop Gain (Output Signal):J100 in the range of to bar (3 to 15 psig)J55 in the range of to bar (6 to 30 psig)3582 and 3582iTypical Open Loop Gain (Output Signal):J100 in the range of to bar (3 to 15 psig)J55 in the range of to bar (6 to 30 psig)Operating InfluencesSupply Pressure 3582: Valve travel changes less percent per bar ( percent per 2 psi) changein supply pressureSupply Pressure 3582i : Valve travel changes lessthan percent per bar ( percent per 2 psi)change in supply pressure continued Instruction ManualD200138X0123582, 582i, and 3583 August 20174 Table 1.

7 Specifications for Fisher 3582 and 3582i Valve Positioners (Continued)Operative Temperature Limits(1)Standard Construction3582 and 3582i : -40 to +71_C (-40 to +160_F)3582NS: -40 to +82_C (-40 to +180_F) with EPDM elastomersHigh Temperature Construction3582A and C only: -18 to +104_C (0 to +220_F)without gaugesElectrical Classification for 582iCSA Intrinsically Safe, Explosion proof, Type n,Dust Ignition proof, DIV 2FM Intrinsically Safe, Explosion proof, Type n,Non incendive, Dust Ignition proofATEX Intrinsically Safe, Flameproof, Type nIECEx Intrinsically Safe, Flameproof, Type nRefer to Hazardous Area Classifications and SpecialInstructions for Safe Use and Installation inHazardous Locations, starting on page 8 foradditional : These classifications also apply to the 3582ipositionerHousing Classification for 582iCSA Type 3 NEMA 3, IP54 ATEX IP64 IECEx IP54 Mount instrument with vent on the side or bottom ifweatherproofing is a.

8 These classifications also apply to the 3582ipositionerOther Classifications/CertificationsCUTR Customs Union Technical Regulations (Russia,Kazakhstan, Belarus, and Armenia)INMETRO National Institute of Metrology, Qualityand Technology (Brazil)KGS Korea Gas Safety Corporation (South Korea)NEPSI National Supervision and Inspection Centrefor Explosion Protection and Safety ofInstrumentation (China)Contact your Emerson sales office or Local BusinessPartner for classification/certification specificinformationHazardous Area Classification for 35823582 valve Positioners comply with the requirementsof ATEX Group II Category 2 Gas and DustNote: This rating does not apply to the 3582iPressure Gauges40 mm ( inch) diameter with plastic case and brassconnection Jtriple scale (PSI, MPa, and bar) orJdual scale (PSI and kg/cm2)Pressure Connections1/4 18 NPTE lectrical Connection for 3582i1/2 14 NPT conduit connectionMaximum Valve Stem Travel105 mm ( inches); adjustable to obtain lessertravels with standard input signalsCharacterized CamsSee characterized cams sectionApproximate Weight3582: kg ( pounds) 3582i : kg (8 pounds)Declaration of SEPF isher Controls International LLC declares thisproduct to be in compliance with Article 4 paragraph3 of the PED Directive 2014/68/EU.

9 It was designedand manufactured in accordance with SoundEngineering Practice (SEP) and cannot bear the CEmarking related to PED , the product may bear the CE marking toindicate compliance with other applicable EuropeanCommunity : Specialized instrument terms are defined in ANSI/ISA Standard Process Instrument The pressure and temperature limits in this document and any applicable standard or code limitation should not be Normal m3/hr normal cubic meters per hour (0_C and bar, absolute); Scfh Standard cubic feet per hour (60_F and psia).Instruction ManualD200138X0123582, 582i, and 3583 August 20175 Table 2. Specifications for Fisher 3583 Valve Stem Position TransmittersInput Signal105 mm ( inches) of valve stem travel;adjustable to obtain full output signal with lesserstem travelsOutput SignalType: to bar (3 to 15 psig) or to (6 to 30 psig) pneumatic pressureAction: Field reversible between direct and reverseOutput Bellows Pressure Rating(1)See table 9 for minimum and maximum pressureratings (allowable input signal) for each availablerange springSupply Pressure(1)Recommended: bar (5 psi) above upper limit ofoutput signal rangeMaximum: bar (35 psig) or pressure rating ofconnected equipment, whichever is lowerSupply Medium: Air or Natural GasSupply medium must be clean, dry, and noncorrosivePer ISA Standard maximum 40 micrometer particle size in the airsystem is acceptable.

10 Further filtration down to 5micrometer particle size is recommended. Lubricantcontent is not to exceed 1 ppm weight (w/w) orvolume (v/v) basis. Condensation in the air supplyshould be minimizedPer ISO 8573-1 Maximum particle density size: Class 7 Oil content: Class 3 Pressure Dew Point: Class 3 or at least 10_C less thanthe lowest ambient temperature expectedMaximum Steady State Air Consumption(2) bar (20 psig) Supply: normal m3/hr ( scfh) bar (30 psig) Supply: normal m3/hr( scfh) bar (35 psig) Supply: normal m3/hr( scfh)Reference Accuracy 1 percent of output signal spanOperating InfluenceOutput signal changes percent per bar ( percent per 2 psig) change in supply pressureOperative Ambient Temperature Limits(1)Standard Construction3583: -40 to +71_C (-40 to +160_F)High Temperature Construction3583C only.