GX Control Valve and Actuator of DVC2000 Digital ValveController Packing (Pneumatic Actuators) Packing (Electric Actuators) Trim Stop 1. Fisher GX Control Valve , Actuator , andFIELDVUE DVC2000 Digital Valve ControllerW8861 IntroductionScope of ManualThis instruction manual includes installation, maintenance, and parts information for the Fisher GX Control Valve andactuator not install, operate, or maintain a GX Valve without being fully trained and qualified in Valve , Actuator , andaccessory installation, operation, and maintenance.

considerations may be required. Refer to the FIELDVUE DVC2000 Digital Valve Controller Mounting section of this manual for additional instruction. Actuator Disassembly (For Air‐to‐Open Constructions ‐ see figures 18 or 19) 1. Connect a separate air supply to the lower diaphragm casing via the air supply connection on the yoke (as shown in

Tags:

  System, Control, Valves, Considerations, Actuator, Gx control valve and actuator system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fisher GX Control Valve and Actuator System

1 GX Control Valve and Actuator of DVC2000 Digital ValveController Packing (Pneumatic Actuators) Packing (Electric Actuators) Trim Stop 1. Fisher GX Control Valve , Actuator , andFIELDVUE DVC2000 Digital Valve ControllerW8861 IntroductionScope of ManualThis instruction manual includes installation, maintenance, and parts information for the Fisher GX Control Valve andactuator not install, operate, or maintain a GX Valve without being fully trained and qualified in Valve , Actuator , andaccessory installation, operation, and maintenance.

2 To avoid personal injury or property damage, it is important tocarefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If youhave any questions about these instructions, contact your Emerson sales office or Local Business Partner GX is a compact, state of the art Control Valve and Actuator System , designed to Control a wide range of processgases, vapors, and GX is rugged, reliable, and easy to select. It requires no Actuator sizing the Actuator selection is automatic oncethe Valve body construction is GX meets the requirements of both EN and ASME standards.

3 It is available with a complete accessory package,including the FIELDVUE DVC2000 integrated digital Valve ManualD103175X012GX Valve and ActuatorJuly 2018 Instruction ManualD103175X012GX Valve and ActuatorJuly 20182 Table 1. Fisher GX Valve SpecificationsSpecificationsENASMEV alve Body SizeDN15, 20, 25, 40, 50, 80, 100, 150 NPS 1/2, 3/4, 1, 1-1/2, 2, 3, 4, 6 Pressure RatingPN 10 / 16 / 25 / 40 per EN 1092-1CL150 / 300 per ASME ConnectionsFlanged raised face per EN 1092-1 Flanged raised face per ASME Body/Bonnet steelASME SA216 WCC stainless steelASME SA351 CF3M stainless steelCW2M (sizes DN25 through DN100 only)CW2M (NPS 1 through 4 only)ASME SA352 LCCASME SA352 LCCASTM A990 CN3 MCu/ASME SA351 CN7M (Cast Alloy 20)

4 (sizes DN25 through DN100 only)ASTM A990 CN3 MCu/ASME SA351 CN7M (Cast Alloy 20)(NPS 1 through 4 only)CD3MN Duplex SST (sizes DN25 through DN100 only)CD3MN Duplex SST (NPS 1 through 4 only)CF3 304L SST (sizes DN25 through DN100 only)CF3 304L SST (NPS 1 through 4 only)M35-2 (NPS 1 through 4 only)N7M Alloy B2 (NPS 1 through 4 only)Face-to-Face DimensionsConsistent with EN 558-1 Series 1 Consistent with ANSI/ISA per IEC 60534-4 and ANSI/FCI 70-2 Metal seat - Class IV (standard)Metal seat - Class V (optional)PTFE seat - Class VI (optional)(1)Flow DirectionFlow-up (Cavitrol III trim, Flow down)Flow Control CharacteristicsEqual Percentage and LinearTrim StylePort DiametersTrim Style mmMicro-Flow trim (unbalanced) , 14, 22 mmStem-Guided with Contoured Plug (unbalanced)or Port-Guided with Cavitrol III trim (unbalanced)36, 46 mmPort-Guided Plug (unbalanced)

5 70, 90, 136 mmBalanced Trim with Contoured plug or Unbalanced Port-Guided PlugHandwheelAvailable as an optionTravel StopAvailable as an option1. For to 14 mm ports, Class VI shutoff is achieved without PTFE ServicesFor information on available courses for the Fisher GX Valve and Actuator System , as well as a variety of other products,contact:Emerson Automation SolutionsEducational Services - RegistrationPhone: 1-641-754-3771 or 1-800-338-8158E-mail: Installation WARNINGA lways wear protective gloves, clothing, and eyewear when performing any installation operations to avoid ManualD103175X012GX Valve and ActuatorJuly 20183 Personal injury or equipment damage caused by sudden release of pressure or bursting of pressure retaining parts mightresult if service conditions exceed those for which the product was intended.

6 To avoid injury or damage, provide a reliefvalve for over pressure protection as required by government or accepted industry codes and good engineering with your process or safety engineer for any additional measures that must be taken to protect against installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in thisinstruction Valve is intended for a specific range of pressures, temperatures and other application specifications. Applyingdifferent pressure and temperatures to the Valve could result in parts damage, malfunction of the Control Valve or loss ofcontrol of the process.

7 Do not expose this product to service conditions or variables other than those for which the product wasintended. If you are not sure what these conditions are you should contact your Emerson sales office or Local BusinessPartner for more complete specifications. Provide the product serial number (shown on the nameplate, figure 2) and allother pertinent 2. Fisher GX Nameplate Examples (Key 35)GE41229-Sheet 1 WITH SPRING INFORMATIONWITHOUT SPRING INFORMATION(USED PRIOR TO 2009)GE01296 HELECTRIC ACTUATORGG12198-A WARNINGIf you move or work on an Actuator installed on a Valve with loading pressure applied, keep your hands and tools away fromthe stem travel path to avoid personal injury.

8 Be especially careful when removing the stem connector to release all loadingon the Actuator stem whether it be from air pressure on the diaphragm or compression in the Actuator springs. Likewisetake similar care when adjusting or removing any optional travel stop. Refer to the relevant Actuator ManualD103175X012GX Valve and ActuatorJuly 20184If hoisting the Valve take care to prevent people from being injured in case the hoist or rigging slips. Be sure to useadequately sized hoists and chains or slings to handle the Before installing the Valve , inspect it to be certain that the Valve body cavity is free of all foreign material.

9 Clean outall pipelines to remove scale, welding slag and other foreign The Control Valve assembly may be installed in any orientation unless limited by seismic criteria. However, thenormal method is with the Actuator vertical above the Valve . Other positions may result in uneven trim wear, andimproper operation. With some valves , the Actuator may also need to be supported when it is not vertical. For moreinformation, consult your Emerson sales office or Local Business Partner. Flow through the Valve must be in thedirection indicated by the arrow cast on the Use accepted piping practices when installing the Valve in the pipeline.

10 Use a suitable gasket between the Valve andthe pipeline If continuous operation is required during inspection or maintenance, install isolating valves on either side of thecontrol Valve with a bypass Valve to Control the flow while the Control Valve is receiving maintenance. WARNINGP ersonal injury could result from packing leakage. Valve packing is tightened before shipment; however the packing mightrequire some readjustment to meet specific service WARNINGA void personal injury or property damage from sudden release of process pressure or bursting of parts.