Example: tourism industry

Flange Immersion Heaters - Watlow

Flange Immersion Heaters Agency Certified Tubular Heaters Ideal For Heating Liquids, Gases, Tanks and Pressure Vessels Requiring Higher Kilowatts Watlow Flange Heaters , with IECEx and ATEX Ex'd' Features and Benefits certification, are easy to install and maintain. Designed for ANSI and ANSI compatible 2, 21/2, 3 thru 48 inch flanges heating liquids and gases in tanks and pressure vessels, Provides appropriate heater size-to-application and fit Flange Immersion Heaters are ideal for applications requiring Element sheath and Flange materials higher kilowatts. Meets your application needs Watlow Flange Heaters are made with WATROD or Integral thermowells FIREBAR tubular elements brazed or welded to a Flange .

Flange Immersion Heaters Agency Certified Tubular Heaters Ideal For Heating Liquids, Gases, Tanks and Pressure Vessels Requiring Higher Kilowatts

Tags:

  Immersion, Heaters, Flange, Flange immersion heaters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Flange Immersion Heaters - Watlow

1 Flange Immersion Heaters Agency Certified Tubular Heaters Ideal For Heating Liquids, Gases, Tanks and Pressure Vessels Requiring Higher Kilowatts Watlow Flange Heaters , with IECEx and ATEX Ex'd' Features and Benefits certification, are easy to install and maintain. Designed for ANSI and ANSI compatible 2, 21/2, 3 thru 48 inch flanges heating liquids and gases in tanks and pressure vessels, Provides appropriate heater size-to-application and fit Flange Immersion Heaters are ideal for applications requiring Element sheath and Flange materials higher kilowatts. Meets your application needs Watlow Flange Heaters are made with WATROD or Integral thermowells FIREBAR tubular elements brazed or welded to a Flange .

2 Provides convenient temperature sensor insertion and Stock Flange Heaters are equipped with a general purpose replacement without draining the fluid being heated terminal enclosure. Standard, general purpose terminal enclosure Watlow Flange Heaters possess IECEx and ATEX Ex'd' ratings Offers easy access to wiring certifying that the Flange heater enclosure is flameproof. Every Element support(s). enclosure is pressure tested to ensure Heaters are safe and Provides proper element spacing to maximizing heater reliable and meet rigorous standards for electrical safety. performance and life Flange Heaters , with FIREBAR elements, also answer the All units are inspected and/or tested need for liquid Immersion applications requiring high kilowatts Ensures element-to- Flange pressure seals do not leak in small tanks.

3 The FIREBAR element's unique flat surface geometry packs more power in a smaller bundle, with lower Drilled and tapped eyebolt holes or lift lugs on larger Flange Heaters watt density, making it especially well-suited for petroleum- Facilitates lifting during installation based liquid heating applications. WATROD hairpins are repressed (recompacted). Performance Capabilities Provides improved heater life, insulation resistance and heat transfer Watt densities up to 100 W/in2 ( W/cm2). FIREBAR Flange Heaters pack more kilowatts into a smaller Wattages up to three megawatts bundle UL and CSA component recognition up to 600 VAC Includes a conventional round tubular 10 in.

4 (254 mm) Alloy 800/840 sheath temperatures up to 1600 F (870 C) ANSI Flange which can be replaced by a 6 in. (152 mm) ANSI FIREBAR Flange with the same immersed length Passivated 316 stainless steel sheath temperatures up to 1200 F (650 C) Branch circuits are designed for 48 amperes per circuit maximum 304 stainless steel sheath temperatures up to Reduces risk of failure due to excessive temperatures 1200 F (650 C) generated by high amperage Steel sheath temperatures up to 750 F (400 C) UL and CSA component recognition under file numbers FIREBAR Flange Heaters deliver more killowatts in E52951 and 31388 respectively smaller bundles Simplifies obtaining third-party recognition for assembly A conventional round tubular 10-inch ANSI Flange can Hazardous area rating ATEX II 2 G Ex d IIB+H2, T1-6.

5 Be replaced by a 6-inch ANSI FIREBAR Flange with same IEC Ex d IIC: TI-6 Gb immersed length Assures equipment safety HAN-FIH-0413. 2013 Watlow Electric Manufacturing Company, all rights reserved. Typical Applications Stand-off terminal enclosures provide an air-insulating Water: barrier between the Flange and terminal enclosure by Deionized mounting the terminations and wiring away from the Flange . Demineralized Stand-off terminal enclosures are recommended whenever a Clean process operating temperature exceeds 210 F (100 C). This Potable helps minimize terminal enclosure temperatures.

6 Process To order, specify stand-off terminal enclosure. Industrial water rinse tanks Certified Enclosures Vapor degreasers CSA, ATEX or IECEx certified enclosures protect wiring in Hydraulic oil, crude, asphalt hazardous gas environments. These terminal enclosures, Lubricating oils at API specified watt densities covered under CSA file number 61707, ATEX certificate Air and gas flow # SIRA 10 ATEX1155X or IECEx certificate # IECEx CSA. Caustic solutions are available on WATROD Flange Heaters . For Chemical baths additional information contact a Watlow representative. Process air equipment To order, specify CSA or ATEX or IECEx certified Boiler equipment enclosure, area classification, protection method, Freeze protection of any fluid desired temperature code, process temperature ( F), Anti-freeze (glycol) solutions maximum ambient temperature, maximum working Paraffin pressure of application (psig), media being heated and heater mounting orientation (horizontal or vertical) and Flange size.

7 Terminal Enclosure Flange For products that will be installed in hazardous locations, Thermowell please provide the following information: Operating conditions Minimum and maximum ambient temperatures for the installation location FIREBAR Mounting orientation Heating Element Conduit Opening Watlow must understand this information so that an appropriate design can be provided. ASME Pressure Vessel Code Welding Flange assemblies can be provided with an ASME Section VIII, Div. I pressure vessel stamp upon request. WATROD Heating Element Thermostats Options To provide process temperature control, Watlow offers Terminal Enclosures optional single pole, single throw (SPST) and double pole, single throw (DPST) thermostats.

8 General purpose terminal enclosures, without thermostats, are standard on all Flange Immersion Heaters . Unless otherwise specified, thermostats are mounted inside Stand-off Optional terminal enclosures the terminal enclosure. Please verify that the thermostat's Terminal include: Conduit Enclosure Openings sensing bulb outside diameter is compatible with the Flange General purpose with a single or double pole thermostat. heater's thermowell inside diameter. Moisture resistant. Available with or without a single or Ref. 6 in. Thermocouples double pole thermostat. (152 mm).

9 Stand-off ASTM Type J or K thermocouples offer more accurate Corrosion resistant. Available ANSI with or without a single orHeight Flange sensing of process and/or sheath temperatures. A. double pole thermostat. thermocouple may be inserted into the thermowell or Explosion resistant Class 1, Div. 1 and 2, Groups B, C attached to the heater's sheath. and D, T1 -T6. Available with or without a single or double Thermocouples are supplied with 120 in. (3050 mm) leads pole thermostat. (longer lead lengths available). Unless otherwise specified, Explosion/moisture resistant combinations.

10 Available with thermocouples are supplied with temperature ranges. or without a single or double pole thermostat. Using a thermocouple requires an appropriate temperature Stand-off Terminal Enclosures and power controller. These must be purchased separately. Watlow offers a wide variety of temperature and power Ref. 6 in. Stand-off (150 mm). ANSI. Flange controllers to meet virtually all applications. Temperature Conduit Openings Terminal Stand-off Height controllers can be configured to accept process variable Enclosure inputs, too. Contact a Watlow representative for details.


Related search queries