Transcription of Flexible Fire Curtains - Delta Pyramax
1 Fibershield-SFibershield-H / HCFibershield-UL 10 BFibershield-PFibershield-EFibershield-W Fibershield-FFibershield-IFibershield-Fi xHiddenshieldControl UnitsFlexible fire CurtainsGerman regulations demand a minimum distance of 10' to 16'5"between buildings. Subject to a lower deviation of these requirements the adjacent walls need to be designed as fire walls. Openings have to be closed in a fire -resistant manner to avoid the passage of fire . How to guarantee this if operable windows are planned?The protection is assured by the possibility to install them inside or outside the building. With this automatic sealing system, operable standard windows without fire -rated glazing can be used. Therefore the room comfort is not restricted. The robust functionality is approved by a weathering test for 10 years made by the MFPA to seal large openings in walls which create fire compartments according to the protection target although the available space is limited or other architectural demands exist?
2 These automatic systems are very small and easily integrated into any situation. You may choose between the protection targets E90-240 or EI30-120 depending on the fire protection classification ( invisible fire protection ).1. For openings in walls How to seal large openings in ceilings which create fire compartments according to the protection target although the available space is limited or architectural demands exist?These automatic systems are very small and easily integrated into any situation. You may choose between the protection targets E90-120 , EW60-120 or EI30-120 depending on the fire protection classification ( invisible fire protection ). 2. For openings in ceilings Provided that no limitations caused by side guides or columns can be accepted (as in the case of prestigious buildings) how to adjust the existing high demands of fire protection closures to architectural constructions even when it has to create a room or has to go around the corner?
3 fire protection closure Fibershield-S offers a polygon shaped design without the necessity of disturbing side guides but still maintaining the required tightness. Due to the flat design, the system is easily integrated into ceilings and can be built with extremely large widths and as the angle may be between 30 and 150 . 3. For fire protection which goes around the corner When buildings or parts of a building connect to each other in a corner situation or if they are separated by a fire wall, no openings in the fire wall are allowed within 16'5". This does not apply in situations when parts of the building connect to each other at an angle of more than 120 . How to guarantee this if operable windows are planned?The protection is assured by the possibility to install them inside or outside the building.
4 With this automatic sealing system, operable standard windows without fire -rated glazing can be used. Therefore the room comfort is not restricted. 4. For openings in fa ades in corner situations 5. For openings in fa ades with a minor distance between the buildingsWhen the roof of building extensions join to walls with openings or to walls which are not fire -retardant, the fire rating of these walls within the distance of 16'5" . How to solve this problem?The protection is assured by the possibility to install them inside or outside the building. With this automatic sealing system, operable standard windows without fire -rated glazing can be used. Therefore the room comfort is not restricted. 6. For openings in fa ades and canopies A textile fire protection closure designed as a barrier that pre-vents the passage of flames from one level to another.
5 How to solve this problem without limiting the field of view? fire protection closures which are integrated into a building and being activated by fire detection or a thermal release mechanism create automatically in the case of fire a fire To prevent the passage of fire from one level to another The creation of sections within fire compartments limits the risk of fire to especially endangered machines or installations. How to achieve such a sealing?The fire protection closures Fibershield creates the required walls or even ceilings. In case of a fire , these rooms can be flooded by high pressure water-spray extinguishing systems or gas extinguishing systems that extinguish the fire . The fire protection systems are designed in dependence on the allowed leakage.
6 Systems with side guides are used to match the high demands concerning tightness for gas extinguishing systems. 8. To create a sectionProtection concepts with automatic textile fire curtain:Fibershield-PFibershield-EFibers hield-WFibershield-IFibershield-H+HCFibe rshield-SFibershield-FFibershield -WFibershield-F Fibershield -WFibershield-F Fibershield -W Fibershield-H-HCFibershield-W Fibershield-EFibershield-E Fibershield-S fire curtain system: Fibershield-UL 10 B Fibershield-UL 10 B Fibershield-P Fibershield-I 1. Smoke extraction by automatic or fixed textile fire Curtains 2. Smoke Curtains with a curved course 3. Automatic textile smoke curtain with the feasibility to pass through 4. Creation of areas for smoke conduction or as fire protection closure 5.
7 Automatic textile fire curtain 6. Automatic textile fire curtain for openings and walls 7. Automatic textile fire curtain EI 90 without water admission 8. High speed doors with integrated fire protection 9. Automatic textile fire curtain for openings in ceilings10. Automatic textile fire curtain for facades, external installation11. Conveyor system closures for uninterrupted and interrupted conveyor systems12. Conveyor system closures for pneumatic conveyor systems13. fire protection closures for industrial kitchen exhaust system14. Elevator shaft doors as fire protection closure15. fire protection stacking doors16. Isogate fire protection insulation doors and gates17. fire protection hoods for electric devices18. Control units19. CAN BUS cross linked hold open units with approval 20.
8 Emergency power back up unit Powerdrive 400 VAC1896631615201411191112121057131818181 721455St bich innovative fire & smoke protectionAttention: The textile fire curtain are not regulated in the IBC Building Code and has to be approved by the local authorities as an alternate means and protection targets within the fire resistance classes ApprovalsUL 10 B / UL 10 DUL 864 control unitsASTM E 84 fabricsUB III/B-08-012UB III/B-07-003UB 10-035-1UB 11-009-1 Integrity with a limitation of heat transmissionLimitation of the heat transmission is the characteristic to reduce the heat being transferred through a fire protection system to limiting materials. (The protection target EI is achieved by fire load free zone).Protection target EI 30: x = 7 / "Protection target EI 60: x = 11 / "Protection target EI 90: x = 19 / "UB III/B-08-016UB III/B-05-006 IBS 08062415UB III/B-07-10-2 Insulation with intensified sprinkler protectionInsulation is the ability of the system to avoid the transmission of fire caused by heat radiation.
9 The transmission has to be limited in a way, that neither the opposite fire side surface nor any other materials near to this surface ignite and so persons are 12011-Efectis-R0495In case of fire - heat insulation with a water film(The surface temperature is lower than the admissible limit value)(3162/794/10)-AH(3699/959/10)-AH30 4/878/09 3053/504/10 Insulation without water in case of fireCreation of sectionsLimitation of a room which is usually not there to avoid the transmission of flames or hot gases to the room without fire . Enclosure by textile fire protection closures with the targets: limitation of the fire , smothering of the fire , extinguishing of the fire by gases or E +SprinklerE +Water filmEI DryTransmission from one level to anotherExtinguishingAvoidance of transmission of flames from one level to another without (with) balustradeB 15045UB III/B-05-006-A1proof of weatheringIntegrityis the resistance against fire to avoid a passage of flames or hot gases(The protection target EI is achieved by fire load free zone EI 30 = 3'4", EI 60 = 4'11", EI 90 = 6'7".)
10 Protection target EI 30: x = 3'4"Protection target EI 90: x = 6'7" E E 90E 120E 240EW 30EW 60EW 90EW 120EI 90EI 120EI 180EI 90EI 120EI 180EI 30EI 60 The necessary barrier (or lintel) height of 1m is automatically created in case of fireEnclosure by textile fire protection closures with the target to: limit the fire quench the fire extinguish the fire with gases or water-sprayProtection Targetsx = 7 / " - 19 / " depending on the environmentUL 10B for E120UL 10D for E90 UL 10D for E120UL 10C for E120 UB III/B-06-005UB III/B-07-010-1UB III/B-05-020UB III/B-06-016GU IV/97-73UU IV/97-25UB III/B-08-033 3344/097/09 UB / 09-018UB / 09-021UB / 09-020 IBS 08062416UB / 10-018-14 ' / "3' / "7 / "1' 7 / "1' 7 / " St bich - USA References 2012 Harley Marine, Seattle, Washington2012 Historical Sherlock Building, Portland, Oregon2012 Hyatt Place Hotel, El Segundo, California2011 Sargento Foods, Plymouth, Wisconsin 2010 Vancouver Library, Vancouver, Washington 2013 Pharmaceutical Building, Princeton.