Example: biology

FLO W ~ TECH

FLOW ~TECH. AI R DI S T RIBUTIO N SPECIAL I S T. SLBG Supply Linear Bar Grille (Double Defiection Without Damper). SLBR Supply Linear Bar Register (Double Defiection With Damper). RLBG Return Linear Bar Grille (Single Defiection without Damper). RLBR Return Linear Bar Register (Single Defiection With Damper). FAISAL JASSIM INDUSTRIES ( ). P. 0. Box: 1871 Dubai, Tel: +971 4 Z5 8 2 6 4 0. Fax: +971 4 6tll E-mail: fi Website: LINEAR BAR GRILLES. A I R D I S T R I B U T I O N S P E C I A L I S T. APPLICATIONS. FLOWTECH Linear Bar (LB) is a side wall grille with a combination of fixed profile front horizontal blades and optional adjustable vertical rear blades. With its high capacity as well as its pleasant aesthetic appearance FLOWTECH Linear Bar Grilles & Registers are commonly used along sides of relatively large spaces with double void areas such as Domes, Open Lobbies, Malls, Atriums and Buildings Entrances, where both aesthetics and high capacity air volumes are required.

FLO W ~ TECH AI R DI S T RIBUTIO N SPECIAL I S T SLBG SLBR RLBG RLBR Supply Linear Bar Grille (Double Defiection Without Damper) Supply Linear Bar Register

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FLO W ~ TECH

1 FLOW ~TECH. AI R DI S T RIBUTIO N SPECIAL I S T. SLBG Supply Linear Bar Grille (Double Defiection Without Damper). SLBR Supply Linear Bar Register (Double Defiection With Damper). RLBG Return Linear Bar Grille (Single Defiection without Damper). RLBR Return Linear Bar Register (Single Defiection With Damper). FAISAL JASSIM INDUSTRIES ( ). P. 0. Box: 1871 Dubai, Tel: +971 4 Z5 8 2 6 4 0. Fax: +971 4 6tll E-mail: fi Website: LINEAR BAR GRILLES. A I R D I S T R I B U T I O N S P E C I A L I S T. APPLICATIONS. FLOWTECH Linear Bar (LB) is a side wall grille with a combination of fixed profile front horizontal blades and optional adjustable vertical rear blades. With its high capacity as well as its pleasant aesthetic appearance FLOWTECH Linear Bar Grilles & Registers are commonly used along sides of relatively large spaces with double void areas such as Domes, Open Lobbies, Malls, Atriums and Buildings Entrances, where both aesthetics and high capacity air volumes are required.

2 Double Deflection Linear Bar Grille (SLBG). For this purpose FLOWTECH LBG / LBR can be supplied in both straight and curved shapes to suit the interior geometry of the served space. FLOWTECH Linear Bars can also be used as conventional supply and return grilles, or combination. Thereof, blind dummy segments can be ordered to integrate the decorative outlook of the whole wall. Opposed Blades Dampers are supplied by FLOWTECH to achieve precise control over air flow volume. OBD is used for fine tuning of air flow volumes and should not be used as branch volume control damper. Single Deflection Linear Bar Grille (RLBG). In FLOWTECH SLBR & SLBG, vertical rear blades are used for directional air flow control.

3 Typically these blades can be adjusted to achieve the required air distribution pattern. Crown Shape Linear Bar Grille Rev. 0:2005/1 D-1. FLOW "~TECH. AIR DISTRIBUTION SPECIALIST. Material: Standard Widths: Frame and bar blades are made of extruded Linear Bar Grilles I Registers can be supplied in any of aluminum alloy 6063 to T 6 Heat Treat ment. the fo llowing standard widths The Opposed Blades Damper is also extruded aluminum alloy 6063/T6. I 00 mm (4-inches). ISO mm (6-inches). Bar Blade Deflection: 200 mm (8-inches). The front bar blade is supplied 1n one of three configurations: 250 mm (I 0-inches). 300 mm ( 12-inches). I. Zero Deflection Arrangement: (Standard). N o deflection to air flow direction Non-standard sizes can be ordered to the designer specifications t t Opposed Blades Damper (OBD): FLOWTECH OBD is fixed to the rear frame of LBR.

4 By means of "S" clamp for ease of removal and rigid construction. To adjust the OBD opening, tum the adjustment screw available at the front face of t he register (Clockwise to oodeflection (Standard) Open I Counter Clockwise to Close). 2. Single Deflection Arrangement: Curved Segments: The air flow is deflected 15-Deg to one side Curved Segments are available for both sidewall curves (CS) and ceiling curves (CP), with minimum radius of curvature of I OOOmm. For special installations, our technician can visit the project site and take actual measurements to ensure a rrr I so deflection (One way). perfect fit. 3. Double Deflection Arrangement: The air flow is deflected 15-Deg to both sides of grille I sodeflection (Two way) C urved Shape Lmear Bar Gn lle D-2 Rev.

5 0:2005/ I. AIR DIS T RIBU T ION SP E CIAL I S T. (Supply Linear Bar Grill (Double Difflection (SLBG). (B)+ SOmm (B)-10 mm _ - Supply Linear Bar Grille (SLBG). (B) + SOmm E. E. (Y). ro \/\f\1 (B)- 12 mm - -= Supply Linear Bar Register (SLBR). Product Features: The double deflection linear grille is a wall The double deflectio n linear grille is composed of a mounted supply grille used in cooling, heating or air set of fixed horizontal straight bars in t he front face ventilat ion applications. and individually adjustable vertical deflectors in the rear to control air flow pattern. Both are manufac- Front blade w idth is 4mm as standard construction. tured from extruded Aluminium sections.))

6 Special construction can also be manufactured as per customer's require-ment. Rev. 0:2005/ I D-3. A IR D I S T RIBU T IO N SPECIAL I S T. -- Return linear Bar Gnll (Smgle Deflection). (B)+ SOmm (B)-10 mm L Re turn Line ar Bar Gnlle (RLBG). (B) + SOmm 16mm 30mm 1. t \I \f\1 (B)-12 mm _ Re turn Linear Bar Registe r (RLBR). Product Features: set of fixed horizontal straight bars attached to a frame, both are manufactured from extruded T he si ngle deflection linear grille is a wall mounted alumi nium sections. grille, used as an exhaust or return grille in cooling, Blade width is 4mm as standard construction heating or air ventilation applications. Special construction can also be manufactured as per c oustomers requirements T he single deflection linear gri lle is composed of a D-4 Rev.

7 0:2005/ I. LINEAR BAR GRILLES. A I R D I S T R I B U T I O N S P E C I A L I S T. CROWN SHAPE LINEAR BAR GRILLE. Crown Shape Linear Bar Grille Product Features: Crown linear grille is a short radius curved linear grille, especially manufactured to suite the crown head or bottom of circular columns with a minimum radius at 250mm. The crown linear grille can be used as supply grille, Minimum Radius: 250mm return grille, dummy grille, or combination thereof. The crown linear grille has the same performance characteristics as linear grille with length modified as: L effective = 2 (r - ). where, r = curvature radius in meters Crown Shape Linear Bar Grille Leff = equivalent length in meters.

8 Rev. 0:2005/1 D-5. MOUNTING FINISH OPTIONS. Available in Powder Coated RAL 9010 or 9016as standard color Other powder coated fln1shes are available on request roong< opbons are Concealed Spnng roong(CSF). O<"V,gbie Screw F"oong (VSF). ACCESSORIES. CORNER PIECE {CP I/ CP l/CP l). Comer Pieces are iiVallable for all standard SIZes. Contact your local supplier for site measurements. CORN ER PIECES. AvaJiable 1n any combination of B,X,Y & .f. B(mm) X(mm) Y(mm) !.(degree). 100 300 300 45. ISO 600 600 90. 200 800 800 135. 250 1000 1000. 300 1200 1200. r - -- - X- - r 8. -l t Rev 0:200511 D Sa AIR DISTRIBUTION SPECIALIST. I. DDDD-D-A. -1. X B -DODD. I I. RAL Code Colo r W idth in mm or inch Length in mm or inch ~--------------------------~.}

9 Oo Deflection 15 Deflection SLBG : Supply Linear Bar Grille L--------------------------------------- ---l SLBR : Supply Linear Bar Register RLBG : Retum Linear Bar Grille RLBR : Retum Linear Bar Register SLBR-0-1200mm x 300mm - 9016. Stands for Supply Linear Bar Register 0 angle deflection, and with opposed blade damper 200mm wide, and 1200mm long, with powder coated RAL 9016. For Curved Segments, remark of curvature and plan of curvature shall be included in order. (Contact your Local Supplier for actual on-site measurements). D-6 Rev. 0:2005/ I. LINEAR BAR GRILLES. A I R D I S T R I B U T I O N S P E C I A L I S T. GENERAL NOTES. Pages onwards give performance data for all models 5 NC, and Pressure values shown, are based on a and variants, and unless otherwise stated the following linear bar register complete unit with an opposed general notes apply: blade damper in the fully open position for the supply register and without damper for the return 1 Throws shown are to three terminal velocity of linear bar grille.

10 The damper should only be used for , , , (50fpm, 100fpm, fine balancing, as for every doubling of pressure 150fpm) with supply air at conditions with max there is a resulting increase in the noise level of T=10K cooling. +9dB for supply, or +5dB for exhaust. 2 For standard room height of metres, throws 6 Models with reduced necks. should be taken as the distance to the nearest wall There is a 'dilution effect' on performance for these (minimum plan dimension, MPD). models, as the air tends to spread behind the core, reducing throws by up to 20%, depending on the 3 To avoid air flow 'dumping' on cooling cycles at relationship between the neck size and the base the grille core. It is advisable to ensure that neck diffuser size.