Example: bachelor of science

Flowcoat UV (1.5mm) - flowcreteaustralia.com.au

Technical Profile FIRE RESISTANCE - AS/ISO CHF Value - kW/m . Smoke Value 4% (Mean). SLIP RESISTANCE. Method described in Dry & Wet Rating is AS4586-2013 dependant on specification (in accordance with AS4586-2013). Flowcoat UV ( ) The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriate maintenance, longer-term wear and/or surface contaminants (wet or dry). Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) - High performance, hard-wearing, please contact our Technical Advisors for further details positively textured, coloured epoxy THERMAL RESISTANCE.

www.flowcreteaustralia.com.au Flowcoat UV (1.5mm) High performance, hard-wearing, positively textured, coloured epoxy and polyurethane resin coating

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Flowcoat UV (1.5mm) - flowcreteaustralia.com.au

1 Technical Profile FIRE RESISTANCE - AS/ISO CHF Value - kW/m . Smoke Value 4% (Mean). SLIP RESISTANCE. Method described in Dry & Wet Rating is AS4586-2013 dependant on specification (in accordance with AS4586-2013). Flowcoat UV ( ) The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriate maintenance, longer-term wear and/or surface contaminants (wet or dry). Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) - High performance, hard-wearing, please contact our Technical Advisors for further details positively textured, coloured epoxy THERMAL RESISTANCE.

2 And polyurethane resin coating Tolerant up to 70 C. system. WATER PERMEABILITY. Karsten Test Nil (Impermeable). Typically used as a UV and slip resistant, SURFACE HARDNESS. durable coating for industrial applications Koenig Hardness Test 180secs BOND STRENGTH. ASTM D4541 (Pull-Off Test) > *. ABRASION RESISTANCE. Taber Abrader loss per 1000 cycles BS8204: Part 2 Grade AR2 1kg load using CS10 wheels UV LIGHT RESISTANCE. Excellent CHEMICAL RESISTANCE. Contact Technical Department SPEED OF CURE** 10 C 20 C 30 C. Light Traffic 36 hrs 24 hrs 16 hrs Full Traffic 48 hrs 36 hrs 24 hrs Full Chemical Cure 12 days 7 days 6 days These figures are typical properties achieved in laboratory tests at 20 C and at 50% Relative Humidity.

3 Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet/dry). Please contact our Technical Advisers for further details. UV Stable: *Assume concrete or substrate is a minimum of 25 N/mm . The coating offers resistance against harsh Ultra Violet rays. Attractive: Brightens up dull, dark and musty industrial environments. Light N Grey Steel Grey Charcoal Tile Red Low Maintenance: Seamless, hygienic finish, which requires low maintenance. Version Resistant: Light Green Dark Green Steel Blue Mid Blue Hard wearing, durable, chemical and abrasion resistant. The applied colours may differ from the examples shown. For a full colour chart and samples, contact your local Flowcrete office.

4 Model Specification Installation Service System Flowcoat UV The installation should be carried out by a qualified contractor with a documented Finish Gloss quality assurance scheme. For details of Thickness our recommended contractors, contact your Manufacturer Flowcrete Australia Pty Ltd local Flowcrete office. Detailed application Contact + 61 7 3205 7115 instructions are available upon request. Environmental Considerations Preparatory work and application in accordance with manufacturer's instructions. The finished system is assessed as non- hazardous to health and the environment. System Design The long service life and seamless Non Slip Aggregate surface reduce the need for repairs and Flowseal/Deckshield UV maintenance.

5 Environmental and health considerations are controlled during Flowcoat OP manufacture of the products by Flowcrete staff. Aftercare, Cleaning & Maintenance Clean regularly using a single or double Flowprime headed rotary scrubber drier in conjunction with a mildly alkaline detergent. Please refer Products Included In This System to Flowcrete's Cleaning & Maintenance Guide for further information. Layer 1 Flowprime *If Required Layer 2 Flowcoat OP Warranty Layer 3 Flowcoat OP Flowcrete products are guaranteed against Non Slip Aggregate defective materials and manufacture and are sold subject to our standard Warranty, Terms Layer 4 Flowseal/Deckshield UV. and Conditions of Sale', copies of which can be obtained on request.

6 Warranty does Coving not cover suitability, fit for purpose or any Coving can form an integral part of the consequential or related damages. Please flooring system. It creates a sealed finish review warranty in detail before installing the between the floor and wall joint. Please products. refer to Flowtex F1 Coving Mortar for further information. Substrate Requirements Concrete or screed substrate should be a minimum of 25 N/mm , free from laitance, dust and other contamination. Substrate should be dry to 75% RH as per ASTM F2170. (AS1884:2012). Flowcrete Australia Pty Ltd Unit 2 41 Deakin Street Brendale QLD 4500 Australia Tel: +61 7 3205 7115 Fax: +61 7 3205 3116. Unit 1 12 Blackmore Road Smeaton Grange NSW 2567 Australia Tel: +61 2 4648 0397 Fax: +61 2 4648 0719.

7 Email: Method Statement System Flowcoat UV Protect from frost, weather, moisture and contaminant ingress. Specification Non Slip Gloss Finish This specification assumes a concrete Application Equipment compressive strength greater than The use of correct application equipment 25 N/mm , application and curing is critical as incorrect application tools can temperatures of 10 35 C, the presence of result in poor finishing and incorrect material an effective damp proof membrane below consumption. Always test the application substrate and concrete moisture content less equipment prior to commencing work. than 75% RH. If moisture content is above 75%. RH, please contact Flowcrete Australia. The following equipment is recommended for this application.

8 This specification must be read in conjunction with relevant product technical data sheets and the application of all materials is to be strictly in accordance with manufacturer's instructions. Manufacturer Flowcrete Australia Pty Ltd 10-12mm Nap Roller Spike Shoes Address Unit 2, 41 Deakin Street Cover - Lambswool *Rolana or Equivalent Suburb Brendale State QLD. Postcode 4500. Telephone +61 7 3205 7115. Email Slow Speed Drill with Squeegee Helical Mixer Head Outline for Installation Mechanically Prepare Substrate Apply Flowprime *If Required for @ . Porous Surfaces Only Apply Flowcoat OP @ . Apply Flowcoat OP @ . Fully Broadcast Non Slip @ 2kg/m . Aggregate Apply Flowseal/Deckshield UV @ . Storage 12 months in an unopened packaging stored at a temperatures of 5-40 C.

9 Flowcrete Australia Pty Ltd Unit 2 41 Deakin Street Brendale QLD 4500 Australia Tel: +61 7 3205 7115 Fax: +61 7 3205 3116. Unit 1 12 Blackmore Road Smeaton Grange NSW 2567 Australia Tel: +61 2 4648 0397 Fax: +61 2 4648 0719. Email: Safety Precautions Application of Flowprime Wear appropriate Personal Protective The substrate must be surface dry before the Equipment (PPE) including masks, gloves, application of Flowprime. eye protection and protective clothing during mixing and application. Ensure the 1. Mixing Flowprime working area is well ventilated and follow Pack components are pre-weighed for the appropriate Health and Safety guidelines optimum performance. Decant required applicable to the location where the amount of material by weight using digital application is undertaken.

10 Scales. Stir Base A to re-disperse any settlement. Add Material Set-Up Hardener B to the Base A container, and drain Before commencing work ensure that your thoroughly. Mix with a slow speed drill and material is set-up by separating all components helical spinner head for 1 minute, taking care ( Base A, Hardener B, Filler C etc.) to ensure not to entrain air. Transfer to a clean container that all material is correct. Check product labels and remix for 30 seconds. and ensure there are equal amounts of product. 2. Application Site Set-Up Immediately after mixing, apply the Flowprime by squeegee and/or roller. Before commencing work ensure that your site is set-up. Mark the floor according to the specification with masking tape or similar Application of Flowcoat OP.