Example: bachelor of science

FOAMULAR THERMAPINK - Owens Corning

Energy-Saving, Moisture-Resistant XPS InsulationDirect-to-Deck Roofi ng InsulationTHERMAPINK 18 Insulation: ASTM C578 Type X, 18 psi minimumTHERMAPINK 25 Insulation: ASTM C578 Type IV, 25 psi minimum DescriptionOwens Corning FOAMULAR THERMAPINK extruded polystyrene (XPS) insulation is a closed cell, moisture-resistant rigid foam board specially designed for roofi ng applications. Like all FOAMULAR XPS insulation products, FOAMULAR THERMAPINK insulation is made with Owens Corning s patented Hydrovac process technology under strict quality control measures, which helps to make it highly resistant to moisture and permits the product to retain its high R-value year after year even after exposure to moisture.

Energy-Saving, Moisture-Resistant XPS Insulation Direct-to-Deck Roofi ng Insulation THERMAPINK® 18 Insulation: ASTM C578 Type X, 18 …

Tags:

  Owens, Owens corning, Corning, Foamular, Foamular thermapink, Thermapink

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FOAMULAR THERMAPINK - Owens Corning

1 Energy-Saving, Moisture-Resistant XPS InsulationDirect-to-Deck Roofi ng InsulationTHERMAPINK 18 Insulation: ASTM C578 Type X, 18 psi minimumTHERMAPINK 25 Insulation: ASTM C578 Type IV, 25 psi minimum DescriptionOwens Corning FOAMULAR THERMAPINK extruded polystyrene (XPS) insulation is a closed cell, moisture-resistant rigid foam board specially designed for roofi ng applications. Like all FOAMULAR XPS insulation products, FOAMULAR THERMAPINK insulation is made with Owens Corning s patented Hydrovac process technology under strict quality control measures, which helps to make it highly resistant to moisture and permits the product to retain its high R-value year after year even after exposure to moisture.

2 THERMAPINK insulation provides effi ciencies during installation such as direct-to-steel deck with no gypsum board thermal barrier needed in most commercial single-ply and metal roofi ng systems. THERMAPINK insulation can be placed over a concrete deck or directly on a non-fi re-resistance-rated (non ASTM E119 hourly rated) steel roof deck without the need for a thermal barrier board. For additional details, see Underwriters Laboratories (UL) Inc. Roof Deck Construction #457, tested in accordance with ANSI/UL Standard 1256.

3 This application requires that the insulation be capable of spanning across rib openings in the deck and provide reasonable resistance to foot traffi c and other normal roof loads. See the Flute Span Capability chart for recommended minimum THERMAPINK insulation thicknesses applied direct to Features Exceptional moisture resistance and superior insulation for direct-to-deck application in steel deck roofi ng systems Excellent long-term stable insulating performance with an R-value1 of R-5 per inch Exceptional moisture resistance.

4 Long-term durability Limited lifetime warranty2 maintains 90% of R-value and covers all ASTM C578 properties The only XPS foam to be GREENGUARD Children & Schools Certifi edSM The only XPS foam with certifi ed recycled content certifi ed by Scientifi c Certifi cation Systems (SCS) to contain a minimum 20% recycled content Will not corrode, rot or support mold growth Zero ozone depletion potential with 70% less global warming potential than our previous formula Reusable Lightweight, durable rigid foam panels are easy to handle and install Easy to saw, cut or scoreTechnical InformationInstall THERMAPINK insulation with the print side turned down to avoid possible solar heat gain damage until the board is covered.

5 Install only as much THERMAPINK insulation as can be covered the same day. FOAMULAR insulation can be stored outdoors during normal construction cycles. During that time some fading of color may begin due to UV exposure, and, if exposed for extended periods of time, some degradation or dusting of the polystyrene surface may begin. It is best if the product is installed within 60 days to minimize degradation. Once installed and covered, the deterioration stops, and damage is limited to the thin top surface layers of cells.

6 Cells below are generally unharmed and still useful insulation. Additional protection over the THERMAPINK insulation such as added cover boards, refl ective membrane surfaces or pavers may be required in roof areas adjacent to refl ective walls, parapets, rooftop equipment areas, or other vertical surfaces that may refl ect and intensify the sun s product is combustible. For additional information, consult MSDS or contact Owens Corning World Headquarters at 1-800 -GET-PINK . Standards, Codes Compliance Meets ASTM C578 Type X ( THERMAPINK 18 Insulation) or Type IV ( THERMAPINK 25 Insulation)Product Data SheetFOAMULAR THERMAPINK Extruded Polystyrene (XPS) Rigid Foam Insulation UL Classifi ed.

7 A copy of UL Classifi cation Certifi cate U-197 is available at See ICC-ES Evaluation Report ESR-1061 at UL (Underwriters Laboratories) Roof Deck Constructions, tested in accordance with UL 1256, Standard for Fire Test of Roof Deck Constructions including Roof Deck Construction #457 FM (Factory Mutual) Class 1 Roof Decks ASTM E108 Fire Classifi ed Assemblies ASTM E119 Fire Resistance Rated Roof/Ceiling Assemblies UL and FM Wind Uplift Rated Assemblies See , UL On-Line Certifi cations Directory, and FM RoofNav for details on listings, constructions and assemblies Meets California Quality Standards and HUD UM #71a Compliance verifi cation by RADCO (AA-650)

8 Certifi cations and Sustainable Features of FOAMULAR XPS insulation FOAMULAR XPS insulation is reusable FOAMULAR XPS insulation is made with a zero ozone depletion formula Certifi ed by Scientifi c Certifi cation Systems to contain a minimum of 20% pre-consumer recycled polystyrene Certifi ed to meet indoor air quality standards under the stringent GREENGUARD Indoor Air Quality Certifi cation Program and the GREENGUARD Children & Schools Certifi cation ProgramSM Approved under the National Association of Home Builders (NAHB) Research Center Green Seal of Approval Utilizing FOAMULAR XPS insulation can help achieve green Typical Physical Properties1 FOAMULAR THERMAPINK InsulationTHERMAPINK InsulationPropertyTest Method21825 Thermal Resistance3, R-Value (180 day) minimum,hr ft2 F/Btu (RSI, C m2/W)@ 75 F (24 C) mean temperatureASTM C5181 ( )1 ( )2 Thickness10 ( )3 Thickness15 ( )4 Thickness20 ( )@ 40 F ( C) mean temperature1 ( )1 ( )2 ( )3 ( )4 ( )

9 Long Term Thermal Resistance, LTTR-Value3, minimum F ft2 hr/Btu (RSI, C m2/W)@ 75 F (24 C) mean temperatureCAN/ULC S770-031" ( )1 " ( )2" ( )3" ( )4" ( )Compressive Strength4, minimum psi (kPa)ASTM D162118 (124)25 (172)Flexural Strength5, minimum psi (kPa)ASTM C20360 (414)75 (517)Water Absorption6, maximum % by volumeASTM Vapor Permeance7, maximum perm (ng/Pa s m2)ASTM (86)Dimensional Stability, maximum % linear change ASTM Spread8, 9 ASTM E845 Smoke Developed8, 9, 10 ASTM E8445-175 Oxygen Index8, minimum % by volumeASTM D286324 Service Temperature, maximum F ( C) 165 (74)Linear Coeffi cient of Thermal Expansion, in/in/ F (m/m/ C)ASTM x 10-5 ( x 10-5)1.

10 Proper ties shown are representative values for 1" thick material, unless otherwise specifi Modifi ed as required to meet ASTM R means the resistance to heat fl ow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the marked R-value. Follow the manufacturer s instructions carefully. If a manufacturer s fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing.


Related search queries