Transcription of FRONIUS SYMO
1 / Perfect Welding / Solar Energy / Perfect ChargingFRONIUS SYMOP owering commercial projects that last. The FRONIUS DATASYMO 208-240 SYMO 208-240 SYMO 480 SYMO 480 SYMO 208 Recommended PV power (kWp) - - - - - usable input current (MPPT1/MPPT 2) A / A AMax. usable input current total (MPPT 1 + MPPT 2) AMax. array short circuit current A / ANominal input voltage 208 V350 V350 VN/AN/A325 V 240 V370 V370 VN/AN/AN/A 480 VN/AN/A675 V 685 VN/AOperating voltage range200 - 600 V200 - 1,000 V325 - 1,000 VDC startup voltage 200 V360 VMPP Voltage range 300 - 500 V300 - 800 V325 - 850 VMax.
2 Input voltage 600 V1,000 VAdmissable conductor size DCAWG 14-AWG 6 copper direct, AWG 6 aluminum direct, AWG 4-AWG 2 copper or aluminum with input combinerIntegrated DC string fuse holdersNA6- and 6+Max (Isc) input terminal rating 33 A 12 ANumber of MPPT21 OUTPUT DATASYMO 208-240 SYMO 208-240 SYMO 480 SYMO 480 SYMO 208 Max. output power 208 V 9,995 VA11,995 VANANA15,000 VA 240 V9,995 VA11,995 VANANANA 480 VNANA9,995 VA12,495 VANAO utput configuration 208/240 V480 V Delta +N**208 VFrequency range (adjustable)
3 45 - 65 HzNominal operating frequency 60 HzAdmissable conductor size ACAWG 14-AWG 6 Total harmonic distortion < %< %< %< %Power factor range 0-1 continuous output current 208 A 240 ANANANA 480 ANAOCPD/AC breaker size 208 A 240 ANANANA 480 ANAMax.
4 % % % % %CEC Efficiency 208 % % % 240 % %NANANA 480 % %NAThe transformerless FRONIUS Symo is the ideal compact three-phase inverter for all commercial applications. The high system voltage and wide input range ensure maximum flexibility in system design. With low roof loading, NEMA4X and 1,000 V DC rating, the FRONIUS Symo can be mounted in many different ways, including flat on a roof or on a pole.
5 The modern design is equipped with the SnapINverter mounting system, allowing for lightweight, secure and convenient DATA FRONIUS SYMO NWSESnapINverter mounting systemSmart Grid ReadyPC board replacementconceptDesign Flexibility TECHNICAL DATA ( 208/240, 208/240, 480, 480, 208)TECHNICAL DATA ( 480, 480, 480, 480, 480)INPUT DATASYMO 480 SYMO 480 SYMO 480 SYMO 480 SYMO 480 Recommended PV power (kWp) - - - - - usable input current (MPPT1/MPPT 2) A / AMax. usable input current total (MPPT 1 + MPPT 2)51 AMax.
6 Array short circuit current (MPPT 1/MPPT 2) A / ANominal input voltage 480 V685 V695 V710 V720 VOperating voltage range200 - 1,000 VDC startup voltage 200 VMPP-voltage range350 - 800 V400 - 800 V450 - 800 V500 - 800 VMax. input voltage1,000 VAdmissable conductor size DCAWG 14 - AWG 6 copper direct, AWG 6 aluminum direct, AWG 4 - AWG 2 copper or aluminum with input combinerIntegrated DC string fuse holdersNANA6- and 6+Max (Isc) input terminal rating 33 A33 A12 ANumber of MPPT2 GENERAL DATASTANDARD WITH ALL FRONIUS SYMO MODELSD imensions (width x height x depth)
7 X x inchesProtection ClassNEMA 4 XNight time consumption< 1 WInverter topologyTransformerlessCoolingVariable speed fanInstallationIndoor and outdoor installationAmbient operating temperature range-40 F - + 140 F (-40 - +60 C)Permitted humidity0 - 100 % (non-condensing)Elevation 2,000 m (6,562 ft) with a max. input voltage of 1,000 V / 3,400 m (11,155 ft) with a max. input voltage of 850 VDC connection terminals6x DC+ and 6x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminum (solid / stranded)AC connection terminalsScrew terminals 14-6 AWGW arranty10 years / extensions up to 15 and 20 years available 1 Certificates and compliance with standards UL 1741-2010 Second Edition (incl.)
8 UL1741 Supplement SA 2016-09 for California Rule 21 and Hawaiian Electric Code Rule 14H), UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547a-2014, IEEE , ANSI/IEEE , FCC Part 15 A & B, NEC 2017 Article 690, C22. 2 No. , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 GENERAL DATASYMO 208-240 SYMO 208-240 SYMO 480 SYMO 480 SYMO DEVICESSTANDARD WITH ALL FRONIUS SYMO MODELSDC reverse polarity protectionYesAnti islandingInternal; in accordance with UL 1741-2010, IEEE 1547-2003 and NECOver temperature protection Output power derating /Active cooling AFCIYesRapid shutdown compliant Yes (according to NEC 2014)Ground Fault Protection with Isolation Monitor Interrupter YesDC disconnectYesINTERFACESAVAILABLE WITH ALL FRONIUS SYMO MODELSUSB (A socket)Datalogging and inverter update possible via USB2x RS422 (RJ45 socket)
9 FRONIUS Solar Net, interface protocolAVAILABLE WITH THE FRONIUS DATAMANAGER CARD ( ONLY ONE CARD REQUIRED FOR UP TO 100 INVERTERS )Wi-Fi/Ethernet/Serial/ Datalogger and webserverWireless standard b/g/n / FRONIUS , sunspec Modbus TCP, JSON / sunspec Modbus RTU6 inputs and 4 digital I/OsLoad management; signaling, multipurpose I/O1 FRONIUS Limited Warranty Conditions for the USA. Different terms or restrictions may apply in other countries. More Information DATASYMO 480 SYMO 480 SYMO 480 SYMO 480 SYMO 480 Max.
10 Ouput power 480 V14,995 VA17,495 VA19,995 VA22,727 VA23,995 VAOuput configuration 480 V Delta +N**Frequency range (adjustable)45 - 65 HzNominal operating frequency 60 HzAdmissable conductor size (AC)AWG 14-AWG 6 Total harmonic distortion< %< %< %< %< %Power factor range 0 - 1 Max. continuous output current 480 AOCPD/AC breaker size 480 V25 A30 A30 A35 A40 AMax. %CEC Efficiency 480 % % % % %TECHNICAL DATA ( 480, 480, 480, 480, 480)GENERAL DATASTANDARD WITH ALL FRONIUS SYMO MODELSD imensions (width x height x depth) x x inchesProtection ClassNEMA 4 XNight time consumption< 1 WInverter topologyTransformerlessCoolingVariable speed fanInstallationIndoor and outdoor installationAmbient operating temperature range-40 F - + 140 F (-40 - +60 C)Permitted humidity0 - 100 % (non-condensing)