Transcription of 環境設定シート - Fujitsu
1 PRIMERGY. CA92276-8902-02. BX620 S6 .. A .. B BIOS .. BIOS . C Web . Web . D . RAID .. E (Windows). (Windows).. F (Linux).. G .. PRIMERGY BX600.. PRIMERGY BX600 S3 . PRIMERGY BX620 S6 . Microsoft Windows Server 2003 R2, Standard Edition Windows Server 2003 R2, Standard Edition Windows Microsoft Windows Server 2003 R2, Enterprise Edition Windows Server 2003 R2, Enterprise Edition 2003. Microsoft Windows Server 2003 R2, Standard x64. Windows Server 2003 R2, Standard x64 Edition Edition Microsoft Windows Server 2003 R2 , Enterprise x64 Windows Server 2003 R2, Enterprise x64. Edition Edition Microsoft Windows Server 2003 Service Pack SP. Microsoft Windows Server 2008 Standard Windows Server 2008 Standard Windows Microsoft Windows Server 2008 Enterprise Windows Server 2008 Enterprise 2008. Microsoft Windows Server 2008 R2 Standard Windows Server 2008 R2 Standard Windows Microsoft Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Enterprise 2008 R2.
2 Microsoft Windows Server 2008 R2 Datacenter Windows Server 2008 R2 Datacenter Microsoft Windows Web Server 2008 R2 Windows Web Server 2008 R2. Red Hat Enterprise Linux 5 (for Intel64) RHEL 5(for Intel64) RHEL5. Red Hat Enterprise Linux 5 (for x86) RHEL 5(for x86). BIOS,iRMC S2 . BIOS 3C78 iRMC S2 .. Microsoft Windows Windows Server Microsoft Corporation . Intel Xeon Intel Corporation . Linux Linus Torvalds . Red Hat Red Hat Red Hat, Inc.. Copyright Fujitsu LIMITED 2011. 2. PRIMERGY BX620 S6 .. CPU. CPU . ( ) Xeon E5503 (2 GHz/4MB). ( ) Xeon E5506 ( ). ( ) Xeon E5507 ( ). ( ) Xeon L5609 ( ). ( ) Xeon L5630 ( ). ( ) Xeon L5640 ( ). ( ) Xeon E5620 ( ) ( )1 . ( ) Xeon E5630 ( ) ( )2 . ( ) Xeon E5640 ( ). ( ) Xeon X5650 ( ). ( ) Xeon X5660 ( ). ( ) Xeon X5667 ( ). ( ) Xeon X5670 ( ). ( ).. / . ( ) GB(15 Krpm) ( ) GB(15 Krpm). SAS ( ) GB(10 Krpm) ( ) 300 GB(10 Krpm) ( )450 GB(10 Krpm) ( ) 600 GB(10 Krpm). ( ).
3 ( ) 160 GB( ). 0. SATA ( ) 160 GB( ) ( ) 500 GB( ) ( ) 1TB( ). ( ). ( ) 32 GB ( ) 64 GB. SSD. ( ). ( ) GB(15 Krpm) ( ) GB(15 Krpm). SAS ( ) GB(10 Krpm) ( ) 300 GB(10 Krpm) ( )450 GB(10 Krpm) ( ) 600 GB(10 Krpm). ( ). ( ) 160 GB( ). 1. SATA ( ) 160 GB( ) ( ) 500 GB( ) ( ) 1TB( ). ( ). ( ) 32 GB ( ) 64 GB. SSD. ( ). 3. A .. ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1A ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1B ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1C ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ).
4 ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1D ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1E ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 1F ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2A ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2B ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ].
5 ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2C ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2D ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2E ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ). ( ) 2GB [( )PG-RM2DJ2 ] ( ) 2GB [( )PG-RM2DH2 ] ( ) 2GB [( )PG-RM2EP2 ]. 2F ( ) 4GB [( )PG-RM4EP2 ] ( ) 8GB [( )PG-RM8EP2 ] ( ) 16GB [( )PG-RM16ER2 ]. ( ) 4GB [( )PG-RM4ES2 ] ( ) 8GB [( )PG-RM8ES2 ] ( ).. ( ( . ( ) SAS (PG-SM101) ( ) PG-FCD201 . ( ) (PG-CS106) ( ) LAN PG-LND201.))
6 ( ) SAS (PG-248KL) ( ). ( ) SAS (PG-248NL). ( ) SAS (PG-228BL). ( ) SAS (PG-22 DCL). ( ) SCSI (PG-2283L). ( ) (PG-FC204L). ( ) (PG-FC205L). ( ) (PG-FC206L). ( ) LAN (PG-2861L). ( ) Dual port LAN (1000 BASE-T) (PG-2862). ( ) Quad port LAN (1000 BASE-T) (PG-2871). ( ) LAN (10 GBASE-CR) Lowprofile (PG-284GL). ( ) (PG-292BL). ( ). 4. PRIMERGY BX620 S6 . BIOS . BIOS .. BIOS . POST F2 . POST BIOS Main . Press F2 to run Setup Press F12 for BBS POPUP. BIOS .. Ctrl Alt Del . Main .. System Overview System Time *1 HH:MM:SS . System Date *1 ** MM/DD/YYYY . Sync RTC with Mgmt. Blade Enabled ( )Disabled > boot Features boot Features . System Memory: Base Memory . Extended Memory: Extended Memory ). *1 Sync RTC with Mgmt. Blade Disabled . boot Features .. boot Features POST Errors Disabled ( )Enabled NumLock Off ( )On Fast boot Enabled ( )Disabled POST Diagnostic Screen Enabled ( )Disabled boot Menu Enabled ( )Disabled 5.
7 B BIOS . Advanced . ( ) .. Advanced Settings Reset Configuration: *1 No ( )Yes > Peripheral Configuration Peripheral Configuration . Configuration . > Advanced System Configuration Advanced System Configuration . > Advanced Memory Options Advanced Memory Options . > Advanced Processor Options Advanced Processor Options . *1 Exit Get Default Values Yes . Peripheral Configuration . ( ) .. Peripheral Configuration Serial Enabled ( )Disabled Serial Port1 Address *1 3F8/IRQ 4 ( )2F8/IRQ 3 ( )3E8/IRQ 4 ( )2E8/IRQ 3. USB Host Controller USB Speed USB And USB ( )USB USB Devices All ( )None ( )Keyboard And Mouse Only LAN Controller 1 Port 1 & 2 ( )Disabled ( )Port 1. Port 1 Remote boot *2 PXE ( )Disabled ( ) iscsi . Port 2 Remote boot *3 PXE ( )Disabled ( ) iscsi . LAN Controller 2 Port 1 & 2 ( )Disabled ( )Port 1. Port 1 Remote boot *2 Disabled ( )PXE ( ) iscsi . Port 2 Remote boot *3 Disabled ( )PXE ( ) iscsi . LAN Controller 3: Port 1 & 2 ( )Disabled ( )Port 1.
8 Port 1 Remote boot *2 Disabled ( )PXE ( ) iscsi . Port 2 Remote boot *3 Disabled ( )PXE ( ) iscsi . Daughter g Board OPROM *4 Disabled ( ))Enabled PCIe slot OPROM *5 Enabled ( )Disabled *1 Serial Enabled . *2 LAN Controller Port 1 Port 1 & 2 . *3 LAN Controller Port 1 & 2 . *4 Daughter Board . *5 . 6. PRIMERGY BX620 S6 . Advanced System Configuration .. Advanced System Configuration HIGH Precision Event Timer Enabled ( )Disabled I/OAT Enabled ( )Disabled PCIe SR-IOV Disabled ( )Enabled Advanced Memory Options .. Advanced Memory Options Memory Scrubbing Enabled ( )Disabled Memory Redundancy Disabled ( )Mirroring ( )Sparing Memory Power Mode Performance ( )Energy NUMA Optimization Enabled ( )Disabled Advanced Processor Options .. Advanced Processor Options CPU Mismatch Detection Enabled ( )Disabled QPIBus Speed Automatic ( ) ( ) ( ) Core Multi-Processing Enabled ( )Disabled Enhanced SpeedStep Enabled ( )Disabled Enhanced Idle Power State Enabled ( )Disabled Virtualization Tech(VT-x) Enabled ( )Disabled Virtualization Tech(VT-d) Enabled ( )Disabled NX Memory Protection Enabled ( )Disabled Adjacent Cache Line Prefetch Enabled ( )Disabled Hardware Prefetch Enabled ( )Disabled DCU Steamer Prefetch Enabled ( )Disabled DCU IP Prefetch Enabled ( )Disabled Data Reuse Optimization Enabled ( )Disabled Intel(R) HT Technology Enabled ( )Disabled Turbo Boost Tech Enabled ( )Disabled Performance/Power Setting Optimized ( )Traditional Limit CPUID Functions Disabled ( )Enabled CPU.
9 7. B BIOS . Security . ( ) .. Security Settings Supervisor Password Not installed Supervisor Password . User Password Not installed User Password . Set Supervisor Password Press Enter Supervisor Password . Supervisor Password Lock *1 Standard ( )Extended Set User Password Press Enter User Password . Password on boot *1 Disabled ( )Enabled Flash Write Enabled ( )Disabled > TPM (Security Chip) Setting *2 TPM (Security Chip) Setting . *1:Supervisor Password User Password . *2:TPM . TPM (Security Chip) Setting .. Current TPM State *1 Enabled and Deactivated Security Chip Disabled ( )Enabled Change TPM State *2 No Change ( )Enabled & Activate ( )Disable & Deactivate ( )Clear *1:Security Chip Enabled . *2 Security Chip Enabled . Power .. Power Power Failure Recovery Previous State ( )Always On ( )Always Off 8. PRIMERGY BX620 S6 . Server . ( ) .. Server Configuration O/S boot Timeout Disabled ( )Enabled Action *1 Reset ( )Continue ( )Power Cycle Timeout Value *1 10 ( )[1 100].
10 ASR&R boot Delay 2 ( )[1 30]. Power Cycle Delay 7 ( )[0 15]. Temperature Monitoring Disabled ( )Enabled boot Retry Counter 3 ( )[0 7]. > CPU Status CPU Status . > Memory Status Memory Status . > PCI Status PCI Status . > Console Redirection Console Redirection . > IPMI IPMI . *1:O/S boot Timeout Enable . CPU Status .. CPU Status CPU 1 Status: Enabled ( )Disabled ( )Failed ( )Empty CPU 2 Status: Enabled ( )Disabled ( )Failed ( )Empty Memory Status .. Memory Status CPU1: DIMM 1A: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2A: Enabled ( )Failed ( )Disabled ( )Empty DIMM 1B: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2B: Enabled ( )Failed ( )Disabled ( )Empty DIMM 1C: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2C: Enabled ( )Failed ( )Disabled ( )Empty CPU2: DIMM 1D: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2D: Enabled ( )Failed ( )Disabled ( )Empty DIMM 1E: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2E: Enabled ( )Failed ( )Disabled ( )Empty DIMM 1F: Enabled ( )Failed ( )Disabled ( )Empty DIMM 2F: Enabled ( )Failed ( )Disabled ( )Empty PCI Status.