Example: bankruptcy

高機能無停電電源装置 - Fujitsu Japan

PC PRIMERGY . 2017 12 .. ( ). Smart-UPS SMT1500 RMJ PY-UPAR15/ PY-UPAR152 . 1.. 2.. UPS . UPS .. UPS .. RAS .. UPS LAN . ON/OFF . UPS UPS . PMAN 100 50 PMAN-UPS . 1 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 3.. USB .. Smart .. 1.. 2 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 4.. Smart-UPS SMT1500 RMJ. PY-UPAR15/PY-UPAR152. ( ). 1500VA/1200W. 100 VAC. 50/60Hz 12A.. AC 100V 6%. ( ). 50/60Hz ( ). 15A.. *5 5 (25 ). ( ) *4 . 90% 4 . 12V/9AH 4 . 24 . NEMA 5-15P( 2P )*2 *3. NEMA 5-15R 6 . ( / *1 47 W / 199 W. ( / *1) 169 kJ/H / 716 kJ/H. mA. ( ) NEMA 5-15P. W432 D468 (mm). 2U. ( ) (33kg). W594 D603 H251 (mm). *1 / . *2 (12A/1200VA ) . 3 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . *3 2 . 2 3 . *4 ( ). 25 ( ). ( ). VA W UPS . 250 200 55. 375 300 36. 500 400 25. 625 500 19. 750 600 15. 875 700 12. 1000 800 10. 1125 900 8. 1250 1000 7. 1500 1200 5. 4 Copyright 2017 Fujitsu LIMITED.)

pc サーバ primergy(プライマジー) 1 copyright 2017 fujitsu limited 高機能無停電電源装置 更新日 2017 年 12 月 (ラック搭載型) ・高機能無停電電源装置 smart-ups smt1500rmj 【py-upar15/ py-upar152】 1.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 高機能無停電電源装置 - Fujitsu Japan

1 PC PRIMERGY . 2017 12 .. ( ). Smart-UPS SMT1500 RMJ PY-UPAR15/ PY-UPAR152 . 1.. 2.. UPS . UPS .. UPS .. RAS .. UPS LAN . ON/OFF . UPS UPS . PMAN 100 50 PMAN-UPS . 1 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 3.. USB .. Smart .. 1.. 2 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 4.. Smart-UPS SMT1500 RMJ. PY-UPAR15/PY-UPAR152. ( ). 1500VA/1200W. 100 VAC. 50/60Hz 12A.. AC 100V 6%. ( ). 50/60Hz ( ). 15A.. *5 5 (25 ). ( ) *4 . 90% 4 . 12V/9AH 4 . 24 . NEMA 5-15P( 2P )*2 *3. NEMA 5-15R 6 . ( / *1 47 W / 199 W. ( / *1) 169 kJ/H / 716 kJ/H. mA. ( ) NEMA 5-15P. W432 D468 (mm). 2U. ( ) (33kg). W594 D603 H251 (mm). *1 / . *2 (12A/1200VA ) . 3 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . *3 2 . 2 3 . *4 ( ). 25 ( ). ( ). VA W UPS . 250 200 55. 375 300 36. 500 400 25. 625 500 19. 750 600 15. 875 700 12. 1000 800 10. 1125 900 8. 1250 1000 7. 1500 1200 5. 4 Copyright 2017 Fujitsu LIMITED.)

2 PC PRIMERGY . *5 (UPS) .. (Smart-UPS) .. 2%. 2%. 50/60Hz 3Hz . *5 2% ( . 2%). *6 2%. ( 2% . 10ms *5 82 92V 12% . *6 108 119V 12% . (Smart-UPS) .. +10 +35 . 0 +35 . 20 85%RH . 8 90%RH . 0 3,000m 0 15,000m UL1778. EMC VCCI Class A. 5 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 5.. PowerChute Business Edition .. UPS. PowerChute Business AC Edition PowerChute Business Edition . A4 .. PowerChute Network Shutdown .. UPS. PowerChute Network *1. Shutdown LAN . AC . *1 UPS . LAN . 6. UPS ( ). UPS .. PowerChute Business Edition USB . PowerChute Network Shutdown LAN . 6 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . 7.. UPS UPS 3 . UPS Support Desk . UPS OFF . ( UPS ). UPS . ( ) .. UPS .. ( ). UPS UPS .. UPS .. 8.. ( ) . UPS . ( ) UPS .. ( . 80% .. Normal .. ( . ) . Local Power Quality . Local Power Quality Good .. 7 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY .. AC AC . BIOS AC.))

3 BIOS Always On .. UPS . UPS (1 2 1 ) .. 7 14 . UPS . PowerChute Business Edition . ( ) .. OS ( ). OS . OS .. UPS . UPS . ( ) ( Power Off Delay UPS . 1). Power Off Delay UPS .. OS . ( ) ( ). OS . : ( ) . UPS ( +OS + . ) UPS . Power Off Delay . Power Off Delay .. 8 Copyright 2017 Fujitsu LIMITED. PC PRIMERGY . PowerChute Network Shutdown . ( ) . (PY-UPC01) .. UPS . UPS . UPS .. 9.. UL1778.. VCCI A. PY-UPAR15:7(b),8(b) . RoHS . PY-UPAR152: . J-MOSS RoHS .. 9 Copyright 2017 Fujitsu LIMITED.