Example: air traffic controller

Full range of valve regulated Fiber Nickel Cadmium ...

Exclusive patented technology Quality German engineering . FNC VR. full range of valve regulated Fiber Nickel Cadmium batteries (X, H, M and L Types). FNC VR valve regulated NiCd batteries The Ultimate in Low Maintenance Nickel Cadmium batteries - UPS Installations - Power Generation - Switchgear - Telecommunications - Emergency lighting - Renewable Energy - Off shore platforms - Marine Shipboard - Oil & Gas - Engine Starting - Process Plant Control Applications where critical back-up power is required to insure operation of life support and critical high cost systems. FNC VR. HOPPECKE FNC VR valve regulated Low Maintenance NiCd Power Developed with Hoppecke's Proven Fiber Nickel Cadmium battery technology to provide superior performance and reliability when it really counts. SPECIFICATIONS: The extremely low maintenance FNC VR NiCd battery is developed in line with the HOPPECKE proven Fiber Operating temperature range : matrix plate technology.

FNC® VR Full range of valve regulated Fiber Nickel Cadmium batteries (X, H, M and L Types) FNC® VR valve regulated NiCd Batteries The Ultimate in Low Maintenance Nickel Cadmium Batteries

Tags:

  Ranges, Brief, Valves, Full, Batteries, Nickel, Regulated, Valve regulated, Cadmium, Nickel cadmium, Full range of valve regulated fiber nickel cadmium, Full range of valve regulated fiber nickel cadmium batteries

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Full range of valve regulated Fiber Nickel Cadmium ...

1 Exclusive patented technology Quality German engineering . FNC VR. full range of valve regulated Fiber Nickel Cadmium batteries (X, H, M and L Types). FNC VR valve regulated NiCd batteries The Ultimate in Low Maintenance Nickel Cadmium batteries - UPS Installations - Power Generation - Switchgear - Telecommunications - Emergency lighting - Renewable Energy - Off shore platforms - Marine Shipboard - Oil & Gas - Engine Starting - Process Plant Control Applications where critical back-up power is required to insure operation of life support and critical high cost systems. FNC VR. HOPPECKE FNC VR valve regulated Low Maintenance NiCd Power Developed with Hoppecke's Proven Fiber Nickel Cadmium battery technology to provide superior performance and reliability when it really counts. SPECIFICATIONS: The extremely low maintenance FNC VR NiCd battery is developed in line with the HOPPECKE proven Fiber Operating temperature range : matrix plate technology.

2 The addition of the special -50C to +60C. recombinant technology of this battery to the Fiber plate Float Charge: to design gives exceptional reliability in critical applications. The FNC VR battery provides superior performance to Boost Charge: to other valve regulated Nickel Cadmium technologies. Water maintenance period @ : 20 years at 20 C. Recharge time to 90% available capacity: 7 8 hours at normal boost charge voltage Low pressure valve : psi Cell jar/lid: translucent polypropylene, Fiber Nickel Cadmium (FNC) technology opaque flame retardant provides the best solution for long polypropylene, UL-94 V0. reliable battery life with minimal Jar/Lid seal: Welded, leak proof maintenance. Single cell: standard Terminals: Nickel plated steel Designed specifically for UPS, switchgear and high Plate construction: Welded Nickel plated steel rate engine starting applications where the system and non-woven Fiber plate must be totally reliable with minimum maintenance.

3 Electrolyte: 20% potassium hydroxide NO MAINTENANCE: with lithium hydroxide The incorporation of a low-pressure valve and a additive (SG = ). flame arresting vent with the FNC-VR technology, recombines oxygen and hydrogen gasses inside the cell with up to 95% efficiency. The FNC-VR cell technology utilizes the standard FNC flooded Nickel Cadmium battery design and offers major advantages over other valve regulated battery systems, where minimal electrolyte reserve is available Large electrolyte reserve to protect against dry out in the case of a charger failure Not susceptible to thermal runaway and can be operated over a wider temperature range . full range of cells available (X,H, M and L). No water addition or filling is required over a 20. year service life when operated on float charge at 20 deg C. Because of the low gas evolution, no special ventilation of the battery room is required. FNC VR. Fiber Nickel Cadmium unique plate design and superior advantages: FNC Cell Types Available with the FNCVR Low Maintenance Technology Capacities, dimensions and weights: C5 Cell length Cell width Cell height Cell weight with Electrolyte per Type Ah Inch(mm) Inch(mm) Inch(mm) electrolyte cell gal(liter).

4 Lbs(kg). FNCVR 45 L 45 (47) (122) (309) ( ) ( ). FNCVR 66 L 66 (47) (122) (309) ( ) ( ). FNCVR 90 L 90 (72) (122) (309) ( ) ( ). FNCVR 110 L 110 (72) (122) (309) ( ) ( ). FNCVR 132 L 132 (92) (122) (309) ( ) ( ). FNCVR 154 L 154 (92) (122) (309) ( ) ( ). FNCVR 176 L 176 (115) (122) (309) ( ) ( ). FNCVR 198 L 198 (115) (122) (309) ( ) ( ). FNCVR 222 L 222 (92) (194) (309) ( ) ( ). FNCVR 259 L 259 (92) (194) (309) ( ) ( ). FNCVR 296 L 296 (115) (194) (309) ( ) ( ). FNCVR 333 L 333 (115) (194) (309) ( ) ( ). FNCVR 370 L 370 (115) (194) (309) ( ) ( ). FNCVR 407 L 407 (155) (198) (309) ( ) ( ). FNCVR 444 L 444 (155) (198) (309) ( ) ( ). FNCVR 481 L 481 (155) (198) (309) ( ) ( ). FNCVR 518 L 518 (155) (198) (309) ( ) ( ). C5 Cell length Cell width Cell height Cell weight with Electrolyte per Type Ah Inch(mm) Inch(mm) Inch(mm) electrolyte cell gal(liter). lbs(kg). FNCVR 40 M 40 (47) (122) (309) ( ) ( ). FNCVR 60 M 60 (47) (122) (309) ( ) ( ). FNCVR 80 M 80 (72) (122) (309) ( ) ( ).

5 FNCVR 100 M 100 (72) (122) (309) ( ) ( ). FNCVR 120 M 120 (92) (122) (309) ( ) ( ). FNCVR 140 M 140 (92) (122) (309) ( ) ( ). FNCVR 160 M 160 (115) (122) (309) ( ) ( ). FNCVR 180 M 180 (115) (122) (309) ( ) ( ). FNCVR 200 M 200 (92) (194) (309) ( ) ( ). FNCVR 235 M 235 (92) (194) (309) ( ) ( ). FNCVR 265 M 265 (115) (194) (309) ( ) ( ). FNCVR 300 M 300 (115) (194) (309) ( ) ( ). FNCVR 333 M 340 (155) (198) (309) ( ) ( ). FNCVR 367 M 367 (155) (198) (309) ( ) ( ). FNCVR 400 M 400 (155) (198) (309) ( ) ( ). FNCVR 433 M 433 (155) (198) (309) ( ) ( ). Spacing required between cells of inch (5 mm). Steel trays for transport and handling are available on request Data subject to change at any time. FNC VR. Fiber Nickel Cadmium unique plate design and superior advantages: FNC Cell Types Available with the FNCVR Low Maintenance Technology Capacities, dimensions and weights: HIGH RATE and X-TRA HIGH Rate cells for UPS and Engine Start Applications: C5 Cell length Cell width Cell height Cell weight with Electrolyte per Type Ah Inch(mm) Inch(mm) Inch(mm) electrolyte cell gal(liter).

6 Lbs(kg). FNCVR 35 H 35 (47) (122) (309) ( ) ( ). FNCVR 46 H 46 (47) (122) (309) ( ) ( ). FNCVR 58 H 58 (72) (122) (309) ( ) ( ). FNCVR 69 H 69 (72) (122) (309) ( ) ( ). FNCVR 80 H 80 (72) (122) (309) ( ) ( ). FNCVR 93 H 93 (92) (122) (309) ( ) ( ). FNCVR 104 H 104 (92) (122) (309) ( ) ( ). FNCVR 115H 115 (115) (122) (309) ( ) ( ). FNCVR 125 H 125 (115) (122) (309) ( ) ( ). FNCVR 135 H 135 (115) (122) (309) ( ) ( ). FNCVR 140 H 140 (92) (194) (309) ( ) ( ). FNCVR 160 H 160 (92) (194) (309) ( ) ( ). FNCVR 180 H 180 (92) (194) (309) ( ) ( ). FNCVR 200 H 200 (115) (194) (309) ( ) ( ). FNCVR 220 H 220 (115) (194) (309) ( ) ( ). FNCVR 240 H 240 (115) (194) (309) ( ) ( ). C5 Cell length Cell width Cell height Cell weight with Electrolyte per Type Ah Inch(mm) Inch(mm) Inch(mm) electrolyte cell gal(liter). lbs(kg). FNCVR 28 X 28 (47) (122) (250) ( ) ( ). FNCVR 47 X 47 (72) (122) (250) ( ) ( ). FNCVR 66 X 66 (92) (122) (250) ( ) ( ). FNCVR 85 X 85 (115) (122) (250) ( ) ( ).

7 FNCVR 39 X 39 (47) (122) (309) ( ) ( ). FNCVR 65 X 65 (72) (122) (309) ( ) ( ). FNCVR 91 X 91 (92) (122) (309) ( ) ( ). FNCVR 117 X 117 (115) (122) (309) ( ) ( ). FNCVR 130 X 130 (92) (194) (309) ( ) ( ). FNCVR 142 X 142 (92) (194) (309) ( ) ( ). FNCVR 153 X 153 (92) (194) (309) ( ) ( ). FNCVR 165 X 165 (115) (194) (309) ( ) ( ). FNCVR 177 X 177 (115) (194) (309) ( ) ( ). FNCVR 189 X 189 (115) (194) (309) ( ) ( ). FNCVR 200 X 200 (115) (194) (309) ( ) ( ). Spacing required between cells of inch (5 mm). Steel trays for transport and handling are available on request Data subject to change at any time. HOPPECKE batteries Inc 1960 Old Cuthbert Road, Suite 130. Cherry Hill, NJ 08034. phone: 856-616-0032 . fax: 856-616-0132. Rev 12-10. FNC VR.