Transcription of Furuno Marine Electronics & Navigation Operators …
1 color LCD SOUNDERFCV-1150 operator 'S MANUALM odelIMPORTANT NOTICESG eneral The operator of this equipment must read and follow the descriptions in this manual. Wrong op-eration or maintenance can cancel the warranty or cause injury. Do not copy any part of this manual without written permission from Furuno . If this manual is lost or worn, contact your dealer about replacement. The contents of this manual and equipment specifications can change without notice. The example screens (or illustrations) shown in this manual can be different from the screensyou see on your display. The screens you see depend on your system configuration and equip-ment settings. Save this manual for future reference. Any modification of the equipment (including software) by persons not authorized by Furuno will cancel the warranty. All brand and product names are trademarks, registered trademarks or service marks of theirrespective to discard this productDiscard this product according to local regulations for the disposal of industrial waste.
2 For disposal in the USA, see the homepage of the Electronics Industries Alliance for the correct method of to discard a used batterySome Furuno products have a battery(ies). To see if your product has a battery(ies), see the chapter on Maintenance. Follow the instructions below if a battery(ies) is the European UnionThe crossed-out trash can symbol indicates that all types of batteries must not be discarded in standard trash, or at a trash site. Take the used batteries to a battery collection site according to your national legislation and the Batteries Directive 2006/66/EU. In the USAThe Mobius loop symbol (three chasing arrows) indicates that Ni-Cd and lead-acid rechargeable batteries must be recycled. Take the used batteries to a battery collection site according to local the other countriesThere are no international standards for the battery recycle symbol. The number of symbols can increase when the other countries make their own recycle symbols in the INSTRUCTIONSWARNINGWARNINGELECTRICAL SHOCK HAZARD Do not open the voltage exists inside the equipment.
3 Refer repair to authorized service turn off the power at theswitchboard if something is dropped into the use of the equipment can cause fire or electrical shock. Immediately turn off the power at theswitchboard if the equipment is emitting smoke or use of the equipment can cause fire or electrical shock. Contact a Furuno agent for not disassemble or modify the , electrical shock or injury can not put containers with liquids on the top of the , electrical shock or injury can you feel that the equipment is acting abnormally, immediately turn off the power at the the equipment is excessively warmor making strange noises, immediately turn off the equipment at the switch- board. Keep the equipment away from rainand water , electrical shock or injury can result if water leaks into the the proper of an incorrect fuse can damage the equipment and can cause not operate the equipment with wet shock can a potentially hazardous situation which, if not avoided, could result in death or serious a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.
4 Warning, Caution Mandatory Action Prohibitive ActionThe operator and installer must read the applicable safety instructions before attempting to install or operate the INSTRUCTIONSP roperly adjust the little gain may present no picture. Too much gain shows excessive noise on the picture. Using the depth data for Navigation when the gain is incorrectly set can lead to a dangerous data presented by this equipment is intended as a source of Navigation prudent navigator never relies exclusively on any one source of navi- gation information, for safety of vessel and not transmit with the transducer out of transducer will be not use depth information for Navigation while the picture advancespeed is set to "stop".The depth indication is not refreshed while the picture is stopped. Use of depth data for Navigation in this case could lead to grounding or other dangerous situation. Do not handle the LCD's panel roughly; it is made of can result if the glass avoid electrical shock, do not remove cover.
5 No user-serviceable parts : Warning Label (1) Type: 86-003-1011-3 Code No.: 100-236-233-10 WARNINGTo avoid electrical shock,do not remove user-serviceable LabelsWarning labels are attached to the equipment. Do not remove the a label is missing or illegible, contact a Furuno agent or dealer about : Warning Label (2) Type: 803-129-1001-3 Code No.: 100-236-743-10 FOREWORDA Word to FCV-1150 OwnersCongratulations on your choice of the furu -NO FCV-1150 color LCD sounder . We are confident you will see why the Furuno name has become synonymous with quality and 1948, Furuno Electric Company has enjoyed an enviable reputation for innovative and dependable Marine Electronics equip-ment. This dedication to excellence is fur-thered by our extensive global network of agents and equipment is designed and constructed to meet the rigorous demands of the Marine environment. However, no machine can per-form its intended function unless installed, op-erated and maintained properly.
6 Please carefully read and follow the recommended procedures for operation and would appreciate hearing from you, the end-user, about whether we are achieving our purposes. Thank you for considering and purchasing Furuno Furuno FCV-1150 is a dual frequency color LCD sounder . Comprised of a display unit and a transducer, the FCV-1150 displays underwater conditions on a color LCD in various colors according to echo main features of the FCV-1150 are Furuno Free Synthesizer (FFS) trans-ceiver design allows use of user-selectableoperating frequencies. Bright LCD gives excellent readability evenin broad daylight. 64- color (including background) presenta-tion provides detailed information on fishdensity and bottom composition. Automatic operation selects correct rangeand gain to show fish echoes and bottom inboth shallow and deep waters. In addition to the conventional gain setting,Gain may be applied to the whole display.
7 Alarms: Bottom, Fish (bottom lock and nor-mal), Speed*, Water Temperature*, and Ar-rival*. Edge function of white marker traces thebottom contour with a thin white line. Zero line may be removed to look for fishnear the surface. Accu Fish provides at-a-glance recognitionof fish size, with fish symbols and size ordepth indication. (Available with transducer50/200-1T.) Heaving compensation for stable picture al-ways.* User-programmable nav data displays pro-vide analog and digital nav data. Waypoints (up to 20) for marking importantlocations. Destination waypoint feature providesrange, bearing and time-to-go to destina-tion waypoint.* Requires appropriate LCDThe display device employs a high quality TFT LCD which displays better than of its pixels. The remaining pixels may drop out or light, however this is not an indication of UNITCV-1150 Power12-24 VDCR ectifierPR-62100/110/115/ 220/230 VAC1 , 50/60 HzSatelliteCompassNavNet 3D orNavNet TZtouchBasic configuration is shown with a solid sensorT-04 MSB, T-04 MTBS peed/temp sensorST-02 MSB, SHIFT Shift the display range.
8 (Inoperative when auto range or auto shift is active.)2 MODES elect display : Show the auto range setting : Manually select range. (Inoperative when auto range is active.)4 FUNCTIONLong push: Display function key setting push: Display window : Select item in setting , 6 GAIN HF,GAIN LFPush: Display high or low frequency auto gain setting : Manually adjust gain. (Inoperative when auto gain is active.)7 ENTER (Cursor pad) Select items on menus. Change settings Move VRM. Push ENTER key to confirm Open/close menu. Escape from current Turn power on (momentary push) and off (long push). Open display brilliance setting window, with power turned position of an important echo as a waypoint. (Output latitude and longitude position to a chart plotter if connected.)ENTERBRILLW hile pressing the center of the cover with your thumbs as illustrated, pull the cover towards TO REMOVE THE HARD COVERRANGEFUNCTIONMODEDUALHFLFZOOMUSER-2 USER-1 ZOOMSHIFTLFHFGAIN51005100 PUSH AUTOMENUMARKESC12345769810 PUSH AUTOPUSH1.
9 On/OffPress the /BRILL key to turn on the power. The unit beeps, the startup screen appears and then the last-used display is turn off the power, press the /BRILL key more than three seconds. The time re-maining until power off is counted down on the Display Brilliance1. With the equipment powered, press the/BRILL key momentarily to show the brilliance adjustment Press the /BRILL key to adjust bril-liance. Continuous pressing changes thebrilliance cyclically.(0 1 .. 9 8 .. 0 1 ..). "0" isthe lowest and "9" is the can also use or for the Press the ENTER or MENU/ESC key tosave the setting and close the window.(The window is automatically closed if thebrilliance is not adjusted within seconds.) a DisplayThe FCV-1150 has seven display modes: low frequency display, high frequency display, dual frequency display, low frequency+zoom, high frequency+zoom, user 1 display, and user 2 display. Select one with the MODE control as shown in the procedure : This function is inoperative if Gain/Mode on the Navnet menu is set for NavNet.
10 See for Rotate the MODE control to open themode selection Rotate the MODE control to select a frequency displayLow frequencyThe lower the frequency of the ultrasonic sig-nal, the wider the detection area. Therefore, the high frequency is useful for general detec-tion and judging bottom frequencyThe higher the frequency of the ultrasonic sig-nal, the better the resolution. For this reason the low frequency is ideal for detailed obser-vation of fish No. (LF/HF)( ): Mode indication at the top of the screenBL: Bottom Lock LF: Low FrequencyBZ: Bottom Zoom HF: High FrequencyMZ: Marker Zoom BD: Bottom DiscriminationLOW frequency zoom mode (BL-LF, BZ-LF, MZ-LF, BD-LF)Low frequency single mode (LF)High frequency single mode (HF)High frequency zoom mode (BL-HF, BZ-HF, MZ-HF, BD-HF)User 1, 2 LowfrequencyHighfrequency1. frequency displayThe low frequency picture appears on the left; the high frequency picture on the right.