Galintel Steel LintelsGalvanising Services pty ltdGalintel pty ltdWeldlok Industries pty ltdGraham Group pty ltdMastermesh Industries pty ltdselection guide & load tablesCONTENTSC ompany Profile 2 General Information 3 Solid Base Angles & Flats 4 Traditional Angles 6 Rendabar 7 Multi-Rib T-Bar 9 Traditional T-Bar 10 Cavi-T-Bar 11T-Bar Section Properties 13 Frequently Asked Questions 14 Stock Length Guide 15 Galintel Pty LtdA division of the Graham GroupAn Australian owned Companywith more than 50 years experienceThe Graham Group is now part of the Nepean Group, one of Australia s leading privately owned engineering and industrial manufacturing is Australia s leading designer and manufacturer of high quality Steel Lintels for the building industry.

Galintel® Solid Base Angles & Flats Safe Load Tables Angles & Flats – safe load tables Unless otherwise indicated, load values in the tables are limited by stress. For example, for a span of 2100mm, a 150 x 100 x 2400 Galintel® may have

Tags:

  Table, Steel, Span, Lletin, Galintel, Galintel steel lintels

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Galintel Steel Lintels - Bricks, Blocks, Pavers, …

1 Galintel Steel LintelsGalvanising Services pty ltdGalintel pty ltdWeldlok Industries pty ltdGraham Group pty ltdMastermesh Industries pty ltdselection guide & load tablesCONTENTSC ompany Profile 2 General Information 3 Solid Base Angles & Flats 4 Traditional Angles 6 Rendabar 7 Multi-Rib T-Bar 9 Traditional T-Bar 10 Cavi-T-Bar 11T-Bar Section Properties 13 Frequently Asked Questions 14 Stock Length Guide 15 Galintel Pty LtdA division of the Graham GroupAn Australian owned Companywith more than 50 years experienceThe Graham Group is now part of the Nepean Group, one of Australia s leading privately owned engineering and industrial manufacturing is Australia s leading designer and manufacturer of high quality Steel Lintels for the building industry.

2 The specialised range of Lintels includes flats, angles, T-bars and Rendabar , all designed for optimum support of brickwork above clear openingsThe innovative design of Galintel products enables weight savings of up to 40% while maintaining strength, structural rigidity and load bearing products are hot-dip galvanised to Australian Standards to ensure that all surfaces (legs, edges and ends) are fully undergo CSIRO Building Products & Systems Appraisal and comply with the requirements of the Building Code of Australia. Engineering certification of structural adequacy is verified by independent testing at the University of NSW and Sydney are approved by housing authorities and local government bodies in all a l i n t e l T- B a rL i c e n c e N o.

3 9 4 2 1 5 S t a n d a r d s A u s t r a l i aG a l v a n i s e d L i n t e l B a r sL i c e n c e N o . 8 7 1 6 7 S t a n d a r d s A u s t r a l i aG a l v a n i s e d L i n t e l B a r sL i c e n c e N o . 8 7 1 6 7 S t a n d a r d s A u s t r a l i a2 Use the simple guides in this brochure and select the right Galintel every time, for: > Peace of mind > Superior performance > Long life and durabilityGenuine Galintel hot-dip galvanised Steel Lintels are 40% lighter than solid Lintels (and 40% easier to carry) with a high strength to weight ribbed Galintel profile creates a superior bond with the mortar.

4 The brickwork, mortar and lintel work together to form a composite beam with exceptional strength and load-carrying won t have to worry about corroded Lintels and cracked brickwork, thanks to the generous galvanising layer including the ends of the product where corrosion often Galintel bars comply with the following standards:> Hot-dip galvanised to AS/NZS4680:2006> Up to R3 durability ratings in accordance with :2001> Loads in accordance with :2002 Compliance with codes and standards is guaranteed Galintels have CSIRO approval, backed by research conducted by the University of NSW and Sydney & corrosion resistance (R3 rating)All Galintel products are hot-dip galvanised with a heavy zinc coating of 600 g/m2 which complies with an R3 durability rating.

5 Durability is a function of the thickness of the zinc coating (black Steel is classified as RO and stainless Steel as R5). Galintels can achieve an R4 durability rating when coated with a two-part epoxy coating (contact Galintel for specification sheet).Multi-Rib T-BarRendabarCavi-T-BarTraditional Angle Don t settle for substitutes. Look for the Galintel T-BarTraditional Flat Multi-rib Profile >Heavy Galvanised Coating (600 g/m2) R3 Rating > < Wide Base Support smooth soffitSharp Internal Angle no need to mitre back edge of brickwork >Solid Base Angle Heavy Galvanised Coating (600 g/m2)

6 R3 Rating > < Ribbed Profile < Wide Base Support smooth soffitSharp Internal Angle no need to mitre back edge of brickwork > Galintel Hot-Dip Galvanised Steel LintelsBest Lintel Bar NoneR3 Durability Rating25-year Warranty*Product WarrantyAll Galintel products are guaranteed against defects in materials and Pty Ltd further warrants that its products will suffer no loss of function nor will they adversely affect the masonry within 25 years from the date of installation. For full warranty conditions and registration details visit our website Solid Base Angles & FlatsQuick Selection GuidePROFILE SIZE & LOADING CATEGORYFlat Bar 85 x 75 kg/mNow find the right Galintel profile for your clear spanFollow the colour code from the loading categories above.

7 Add end bearing of 100-150mm to both ends of span . ABDCEHow to use the quick selection guide1. Determine the Loading Category by referring to the diagrams below. 2. Determine the span of the opening, including end bearings, and use the Clear span Length table to find the appropriate Galintel profile. 3. Determine the load to be applied to the Galintel and refer to the Safe Load tables on page 5 to find the correct profile size and stock :Loading Category B (cavity wall construction), 1800mm span with UDL of 1400 kg/m. From the safe load tables on page 5, this requires a Galintel Solid Base Angle with 150mm x 100mm profile and stock length of diagrams represent general domestic and light commercial construction only, using conventional framing materials and standard building load-bearing walls must have at least three courses of bricks over the opening.

8 The wall above the opening should not be subjected to major loads other than those from normal roof, ceiling and floors. Avoid point loads above the opening, such as hot water tanks and roof storage E loadings that do not comply with the above conditions should be referred to a structural engineer. Category ACategory BCategory CCategory DCategory ECategory ACategory BCategory CCategory DCategory ECategory ACategory BCategory CCategory DCategory ERefer to load tables on page 5 for correct profile size and lengthConstruction Category Category A Non-load bearing brick veneer with separate structural timber frame.

9 Category B Cavity wall equally supported on both skins. Supported roof span < 8m. Category C Lightweight sheet roof and ceiling supported on single skin. Supported roof span < 8m. Category D Lightweight timber truss, tiled roof and sheet ceiling supported on single skin. Supported roof span < 8m. Category E Load-bearing internal brickwork under upper storeys. Supported floor span < : Information contained in this brochure does not constitute an offer and is supplied in good faith to aid the user in the correct selection of our products. Every care has been taken to ensure that the information is correct; however, we cannot guarantee its accuracy or completeness and we assume no responsibility for errors or omissions or for any consequences of reliance on this Pty Ltd is committed to continual improvements in our products and we reserve the right to change specifications, details and designs without notice.

10 All dimensions and masses in this brochure are Bar 100 x 1009kg/mAngle Bar 150 x 10012kg/mCLEAR span LENGTH600700800900 120015001800210024002700300036004 Galintel Solid Base Angles & FlatsSafe Load TablesAngles & Flats safe load tablesUnless otherwise indicated, load values in the tables are limited by stress. For example, for a span of 2100mm, a 150 x 100 x 2400 Galintel may have a load of 949 kg/m applied safely, with a maximum long term deflection of 1/600 span or (2100/600 = ).All tables are intended as a guide only. Qualified expert advice should be sought in deciding the suitability of any structural product for a construction = Uniform distributed loadControl JointsWhere control joints are used as a required structural element, loading of the lintel should be reduced by one best results all Lintels must be propped before bricklaying.


Related search queries