Example: barber

Galvanized Rigid Conduit

Calconduit19440 S. Dominguez Hills Dr., Rancho Dominguez, CA 90220Ph: (562) Ph: (800) Calpipe Fax: (310) | Rigid Conduit Application: Calconduit GRC can be installed indoors or outdoors, exposed or concealed, in all kinds of atmospheric conditions, and in hazardous locations, when in accordance with NEC 2002 Article 344. Also, it provides mechanical protection for the conductors while reducing Electro-Magnetic Field (EMF) exposure and shielding against Electro-Magnetic Interference (EMI).Features:Calconduit GRC is threaded on both ends, with a coupling applied to one end and a thread protector to the otherThe pitch of the threads conforms to the American National Standard for pipe threads, general purpose (Inch), ANSI/AMSE are protected after cutting by an application of molten zincHot Dipped Galvanized HDG conduitAmerican National Standards Institute (ANSI )American National Standard for Rigid Steel Tubing (ANSI )Underwriters Laboratories Standard for Rigid Steel Tubing (UL6) National Electric Code 2002 Article 344 (1999 NEC Article 346)adopted the UL6 and ANSI standard).

Calconduit 19440 S. Dominguez Hills Dr., Rancho Dominguez, CA 90220 Ph: (562) 803.4388 Ph: (800) Calpipe Fax: (310) 885.1894 | calconduit.com

Tags:

  Rigid, Conduit, Galvanized, Galvanized rigid conduit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Galvanized Rigid Conduit

1 Calconduit19440 S. Dominguez Hills Dr., Rancho Dominguez, CA 90220Ph: (562) Ph: (800) Calpipe Fax: (310) | Rigid Conduit Application: Calconduit GRC can be installed indoors or outdoors, exposed or concealed, in all kinds of atmospheric conditions, and in hazardous locations, when in accordance with NEC 2002 Article 344. Also, it provides mechanical protection for the conductors while reducing Electro-Magnetic Field (EMF) exposure and shielding against Electro-Magnetic Interference (EMI).Features:Calconduit GRC is threaded on both ends, with a coupling applied to one end and a thread protector to the otherThe pitch of the threads conforms to the American National Standard for pipe threads, general purpose (Inch), ANSI/AMSE are protected after cutting by an application of molten zincHot Dipped Galvanized HDG conduitAmerican National Standards Institute (ANSI )American National Standard for Rigid Steel Tubing (ANSI )Underwriters Laboratories Standard for Rigid Steel Tubing (UL6) National Electric Code 2002 Article 344 (1999 NEC Article 346)adopted the UL6 and ANSI standard).

2 Options:Produced in normal trade sizes from '' to 6'' in standard lengths of 10 feet ( m), including couplingThe quantity in primary bundles is equal to the standard bundle quantityCustom lengths and bends are availableApplicable tolerances: Length: 10Ft ", Outside Diameter: "-2" 0. 015" ; 2- "-4" 0. 025" ; 5"-6" 1% Trade SizeNominal Weight / per 10 0 Ft. w/ couplingsNominal Outside Wall ThicknessLength w/ CouplingLift QuantitiesItem NumberInchesPoundsInchesInchesFeetPieces FeetPoundsST0510CT00 '' ,5002,050ST0710CT00 '' ,0002,180ST1010CT001'' ,2502,013ST1210CT001- '' ,962ST1510CT001- '' ,104ST2010CT002'' ,100ST2510CT002- '' ,068ST3010CT003'' ,181ST3510CT003- '' ,200ST4010CT004'' ,060ST5010CT005'' ,100ST6010CT006'' ,840