Gas Heating ProductsMarch 2006UH-TS-1 Indoor and Outdoor UnitsIndirect fired , Direct fired , andGas Unit HeatersUH-TS-12A Complete Line of Gas Heating ProductsIndirect FiredTrane now offers one of the most complete lines of indoor and outdoor gas Heating Products on the market today!Propeller fan gas unit heaters , centrifugal gas unit heaters , duct furnaces, horizontal blower assemblies, indoor make-up air handlers and rooftop gas Heating units are available in a wide range of sizes with a variety of factory-installed options to meet your application needs. All units are CSA certified, conforming to the toughest standards for safe and efficient operation. Contact the local Trane sales office for more Fan Gas Unit heaters Model GPND/GPPDThe Trane propeller gas unit heater is a complete heat generating and distribution plant equipped with automatic safety controls.

Indirect Fired Trane now offers one of the most complete lines of indoor and outdoor gas heating products on the market today! Propeller fan gas unit heaters, centrifugal gas unit heaters, duct furnaces, horizontal blower assemblies, indoor make-up air handlers and rooftop gas heating units are available in a wide range of

Tags:

  Trane, Fired, Heaters, Fired trane

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Gas Heating Products - Trane

1 Gas Heating ProductsMarch 2006UH-TS-1 Indoor and Outdoor UnitsIndirect fired , Direct fired , andGas Unit HeatersUH-TS-12A Complete Line of Gas Heating ProductsIndirect FiredTrane now offers one of the most complete lines of indoor and outdoor gas Heating Products on the market today!Propeller fan gas unit heaters , centrifugal gas unit heaters , duct furnaces, horizontal blower assemblies, indoor make-up air handlers and rooftop gas Heating units are available in a wide range of sizes with a variety of factory-installed options to meet your application needs. All units are CSA certified, conforming to the toughest standards for safe and efficient operation. Contact the local Trane sales office for more Fan Gas Unit heaters Model GPND/GPPDThe Trane propeller gas unit heater is a complete heat generating and distribution plant equipped with automatic safety controls.

2 Available for natural or propane gas operation, this unit heater carries a ten-year non prorated warranty on the heat exchanger, draft hood assembly and Fan Gas Unit HeatersGPND/GPPD003004006007010012015017 020022025030035040 Input Outlet4"R4"R5"R5"R6"R6"R7"R7"R8"R8"R8"R1 0"OV 10"OV 12"OVCFM70080010501100148016502200253026 4027003100440050005300 Temperature Rise F3042425050565051566160505256 Outlet Velocity70075064067295090010451070100095 0980110011501050 Nominal Horsepower1/301/301/301/301/201/101/41/3 1/31/31/3(2) 1/4 (2) 1/3 (2) 1/3 Motor Full Load Fan Gas Unit heaters Model GCND/GCPDC entrifugal fan gas unit heaters are designed for applications where ductwork or discharge nozzles are used. They are ideal for commercial and institutional applications where a low noise level is desired.

3 A duct discharge flange may be ordered in lieu of horizontal louvers. These gas unit heaters carry a ten-year non-prorated warranty on the heat exchanger, draft hood assembly and Fan Gas Unit HeatersGCND/GCPD010012015017020022025030 035040 Input Outlet6"R6"R7"R7"R8"R8"R8"R10" OV10" OV12" OVFree Air Delivery12001575197523002400260028503950 46004800 Temperature Rise F62595656626465565662 Outlet Velocity88095010301045965935930108010901 000 Nominal Horsepower1/41/31/21/23/43/43/43/411 Motor Full Load Complete Line of Gas Heating ProductsIndirect FiredHigh Efficiency Propeller Fan Gas Unit HeatersModel GHND/GHPDT rane high efficiency propeller fan gas unit heaters can achieve annual fuel savings of 20 to 25 percent or more over conventional gravity-vented heaters .

4 Features include a factory installed flue vent fan and sealed flue collector that control combustion and excess air during the on-cycle. Heated air no longer escapes through the draft diverted opening during the off cycle. Energy-saving intermittent pilot ignition reduces gas losses. The pilot only operates when required. Horizontalpower venting allows for side wall venting, smaller openings and single-walled vent pipe. These high efficiency gas fan unit heaters carry a ten-year non-prorated warranty on the heat exchanger, flue collector and Efficiency Propeller Fan Gas Unit HeaterGHND/GHPD0030040060070100120150170 20022025030035040 Input Outlet (1)5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8"Rec.

5 Flue Size4 R4"R4"R4 R4"R4"R4"R4"R5"R5"R5"R6"R6"R6"RCFM750800 1050110014801650220025302640270031004400 50005300 Temperature Rise F3042425050565051566160505256 Outlet Velocity68072061064077591010451070101095 0980110011501050 Nominal Horsepower1/301/301/301/301/201/101/41/3 1/31/31/3(2) 1/4 (2) 1/3 (2) 1/3 Motor All flue outlets are 5 1/8" 1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 Efficiency Centrifugal Fan Gas Unit heaters Model GBND/GBPDThe Trane high efficiency centrifugal fan gas unit heater incorporates the same features as the high efficiency propeller unit heater. An exceptionally balanced centrifugal blower assembly results in quieter operation. The high efficiency centrifugal fan is also well-suited for high static applications where ductwork is required.

6 Duct discharge flanges may be ordered in lieu of horizontal louvers to accommodate ductwork. Trane s high efficiency centrifugal fan gas unit heatercarries a ten-year non-prorated warranty on the heat exchanger, flue collector and Efficiency Centrifugal Fan Gas Unit HeaterGBND/GBPD0100120150170200220250300 35040 Input Outlet (1)5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"Flue Outlet4"R4"R4"R4"R5"R5"R5"R6"R6"R6"RFree Air Delivery12001575197523002400260028503950 46004800 Outlet Velocity88095010301045965935930108010901 000 Nominal Horsepower1/41/31/21/23/43/43/43/411 Motor All flue outlets are 5 1/8" 1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 Complete Line of Gas Heating ProductsIndirect FiredSeparated Combustion PropellerFan Gas Unit HeatersModel GAND/GAPDThe Trane separated combustion propeller fan gas unit heaters can yield higher seasonal efficiencies.

7 A power venting system draws in a controlled amount of outdoor air for combustion and exhausts flue Products from the building. The burners, pilot and flue system are totally enclosed within the unit, effectively isolating the entire combustion process from the dust, humidity and chemicals in the heater s surrounding Combustion Centrifugal Fan Gas Unit heaters Model GKND/GKPDThe separated combustion centrifugal fan gas unit heater incorporates all the same features as the separated combustion propeller unit heater. In addition, this unit features quiet operation due to an exceptionally balanced centrifugal blower assembly and high static applications where duct work is required. Duct discharge flanges may be ordered in lieu of horizontal louvers to accommodate duct Combustion Propeller Fan Gas Unit HeaterGAND/GAPD0100120150170200220250300 35040 Input Outlet (1)4 R4"R4"R4 R5"R5"R5"R6"R6"R6"RCombustion Air Inlet4 R4"R4"R4 R5"R5"R5"R6"OV6"OV6"OVCFM148016502200253 0264027003100440050005300 Temperature Rise F50565051566160505256 Outlet Velocity77591010451070100095098011001150 1050 Nominal Horsepower1/201/101/41/31/31/31/2(2) 1/4(2) 1/3(2) 1/3 Motor Combustion Centrifugal Fan Gas Unit HeaterGKND/GKPD0100120150170200220250300 35040 Input Outlet (1)

8 4 R4"R4"R4 R5"R5"R5"R6"R6"R6"RCombustion Air Inlet4 R4"R4"R4 R5"R5"R5"R6"OV6"OV6"OVCFM120015751975230 0240026002850395046004800 Temperature Rise F62595656626465565662 Outlet Velocity88095010301045965935930108010901 000 Nominal Horsepower1/41/31/21/23/43/43/43/411 Motor Gas Duct FurnacesModel GDND/GDPDT rane duct furnaces are CSA certified for installation downstream of cooling coils in air conditioning systems. Both LP (propane) and natural gas units are available with left or right-hand controls for ganging of units in the field. Approved in blow-thru applications available with bottom or side access to the burner Gas Duct FurnacesGDND/GDPD01001201501702002202503 0035040 Input CFM2469308637044321493855566173740786429 877 Pressure Temperature Rise F 30303030303030303030 Min CFM9291157138916201852208323152778324137 04 Pressure Temperature Rise F 80808080808080808080 Flue Outlet6"R6"R7"R7"R8"R8"R8"R10"OV10"OV12" OV1.

9 All flue outlets are 5 1/8" 1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 Complete Line of Gas Heating ProductsIndirect FiredHigh Efficiency Indoor Gas Duct FurnaceModel GLND/GLPDThe Trane high efficiency indoor gas duct furnaces can achieve annual fuel savings of 20 to 25 percent or more over conventional gravity vented units. Features include a factory installed flue vent fan and sealed flue collector that control combustion and excess air during the on-cycle. Heated air no longer escapes through the draft diverted opening during the off cycle. Energy saving intermittent pilot ignition reduces gas losses. The pilot operates only when required. Horizontal power venting allows side wall venting, smaller openings and single wall vent pipe.

10 High Efficiency Indoor Gas Duct FurnaceGLND/GLPD010012015017020022025030 035040 Input CFM2469308637044321493855566173740786429 877 Pressure Temperature Rise F 30303030303030303030 Min. CFM9291157138916201852208323152778324137 04 Pressure Temperature Rise F 80808080808080808080 Flue Outlet (1)5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"5 1/8"Rec. Flue Size4"R4"R4"R4"R5"R5"R5"R6"R6"R6"R1. All flue outlets are 5 1/8" 1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 Combustion Indoor Gas Duct FurnacesModel GMND/GMPDThe Trane separated combustion indoor gas duct furnace achieves higher seasonal efficiencies by using outside air for combustion. It overcomes slight negative pressures near exhaust fans or paint booths.