Example: tourism industry

GAS MANIFOLD SYSTEMS & ACCESSORIES

GAS MANIFOLD SYSTEMS & ACCESSORIES anniversary20161946thManifold Catalog: GMF-2016 HOW TO SELECTION AND SIZING ..2 ABOUT SUPERIOR PRODUCTS ..3 MANIFOLD ASSEMBLIES:Simplex manifolds ..4-5 MANIFOLD Header Extensions ..4-5 Modular manifolds ..6 Duplex manifolds ..7 Simple Duplex manifolds ..8 SCMB / CPR Cradle Pack 8 Regulator, MANIFOLD ..9 Commonly Used Pigtails ..9 SEMI-AUTOMATIC manifolds :SAM Series ..10-11 GMC Series ..12 GML ..13 MANIFOLD ACCESSORIES :Fittings and Piping ..14-16 Line Station Drops ..17 Line Station Valves ..17 Line Station Regulators ..17 Valves, MANIFOLD ..18 WARRANTY INFORMATION.

GAS MANIFOLD ASSEMBLIES: Modular 6 www.superiorprod.com Modular Simplex Manifold headers are a single unit design manufactured from free cutting brass bar stock. This design

Tags:

  System, Design, Accessories, Manifolds, Gas manifold systems amp accessories

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GAS MANIFOLD SYSTEMS & ACCESSORIES

1 GAS MANIFOLD SYSTEMS & ACCESSORIES anniversary20161946thManifold Catalog: GMF-2016 HOW TO SELECTION AND SIZING ..2 ABOUT SUPERIOR PRODUCTS ..3 MANIFOLD ASSEMBLIES:Simplex manifolds ..4-5 MANIFOLD Header Extensions ..4-5 Modular manifolds ..6 Duplex manifolds ..7 Simple Duplex manifolds ..8 SCMB / CPR Cradle Pack 8 Regulator, MANIFOLD ..9 Commonly Used Pigtails ..9 SEMI-AUTOMATIC manifolds :SAM Series ..10-11 GMC Series ..12 GML ..13 MANIFOLD ACCESSORIES :Fittings and Piping ..14-16 Line Station Drops ..17 Line Station Valves ..17 Line Station Regulators ..17 Valves, MANIFOLD ..18 WARRANTY INFORMATION.

2 19 Table Of Contents1. Calculate maximum possible usageTotal # of welding/gas use stations X SCFH used per station = max possible usage2. Determine duty cycle (Hours per day of gas use)8 hours/day, 16 hours/day, 24 hours/day3. Determine total gas usage per possible usage X 2. Duty cycle = 3. Total gas usage per day4. Determine gas volume of cylinders to be used(Typical high pressure cylinder = 250 cubic feet, typical liquid = 4500 cubic feet)5. Determine # of cylinders needed per gas usage/day 4. Volume of cylinders = # of cylinders/day6. Determine frequency of cylinder change outs desiredOnce a day, every third day, once a week etc.

3 Gas supplier delivery schedule will help size of each MANIFOLD service bank5.# of cylinders per day X 6. Frequency of changeouts = size of service gas/gas mix, or high pressure is the end use line pressure to application (PSIG) maximum flow rate to application (SCFH) interruption of gas service notification of changeover or gas outage # of cylinders (use How To Properly Size A MANIFOLD below) MANIFOLD Selection CriteriaHow To Properly Size A ManifoldABOUT SUPERIOR PRODUCTSC allfor more information or to place an order in 1948 and celebrating 70 years of providing superior products coupled with excellent customer service, Superior Products continues to thrive and respond to changing markets.

4 With this new product update and extension of our Gas MANIFOLD SYSTEMS and ACCESSORIES , Superior Products offers an expanded line of compressed gas manifolds , regulators, pigtails and Products gas MANIFOLD SYSTEMS provide a reliable and safe way for large volumes of gas to be distributed. MANIFOLD selection begins with choosing the type of MANIFOLD or control section. Superior Products offers header manifolds in a variety of custom configurations and options. Header manifolds include simplex, duplex, modular and simple duplex models. Partner with a MANIFOLD regulator and flexible pigtails for a complete Products semi-automatic manifolds give three options for uninterrupted gas service.

5 All semi-automatic manifolds switch from depleted bank to full bank automatically and can be used for compressed gas or gas withdrawal from liquid dewars. All products in this catalog as designed for standard industrial gases and meet or exceed the specifications on the Compressed Gas Association (CGA) and the National Fire Protection Association (NFPA). All assemblies are tested to at least times working assistance please contact Superior Products customer service department at Superior Simplex MANIFOLD system is designed to provide a single source of supply from one cylinder bank.

6 This MANIFOLD is typically used as a high pressure back-up system for liquid or bulk tank SYSTEMS in both industrial and medical applications. The simplex MANIFOLD has a master shut-off valve with a single row of cylinders. Each header consists of 1/2 pipe, 1/2 tees or crosses, header valves or inlet adaptors with check valves, master shut-off valve, end plug and mounting brackets. The end has a plug that allows for future expansion. The outlet regulator is ordered separately based on the required delivery pressure. SPECIFICATIONS: Maximum inlet pressure: 3000 PSIG MANIFOLD outlet: NPS-RH or NPS-LH 1/2 brazed pipe & tees for maximum leak protection MANIFOLD regulator sold separately (see page 9) Pigtails must be ordered separately (see page 9)GMSM-HVR-580-02 All Superior manifolds are expandable to meet changing application requirements.

7 Header extensions are shipped ready for addition to existing manifolds . Unit includes 1/2 piping, 1/2 tees, header valves or inlet adaptors with check valves and a mounting bracket. The end has an NPT plug that allows for future expansion. All pigtails for Superior manifolds must be ordered separately. Specify right side extension (HVR) or left side extension (HVL) Model shown in photo is right hand header extensionGMHE-HVR-580-02 GAS MANIFOLD ASSEMBLIES: Simplex, Header ExtensionsSimplex manifolds (Left or Right design ) - GMSM SeriesManifold Header Extensions - GMHE Series (regulator sold separately)Ordering your header a pigtailsStaggered ConfigurationCrossover ConfigurationStandard ConfigurationSimplex MANIFOLD ConfigurationsCallfor more information or to place an order MANIFOLD ASSEMBLIES.

8 Simplex, Header ExtensionsORDERING INFORMATIONEXAMPLESGMSM Standard 10 Centers GMSM Standard 13 Centers GMSM Staggered 5 Centers Crossover 10 Centers Standard 10 Centers GMHE Standard 13 Centers GMHE Staggered 5 Centers Crossover 10 Centers Lengths - Simplex Headers & Header Extensions T ype Layout 2 3 4 5 6 7 8 9 10 11 12 320 Carbon Dioxide 326 Nitrous

9 Oxide 346 Air 350 Hydrogen/Methane 02-08 Standard 10 CentersGMSM Simplex MANIFOLD _ HVR Header Valve, Right-Hand _ 500 Medical Mixtures _ 02-06 13 Centers for Fuel GasGMHE Header Extension HVL Header Valve, Left-Hand 510A Acetylene 02-12 C Crossover 10 Centers CV Check Valve 510P Propane, Propylene 02-12 S Staggered 5 Centers 540 Oxygen 580 Nitrogen, Argon, Helium 590 Industrial Air Simplex MANIFOLD Headers and Extensions Type -Inlet Type - CGA # -# of Inlets & LayoutGMSM-CV-540-03 Simplex MANIFOLD with three CGA-540 check valve inletsGMHE-CV-540-02 Header extension with two CGA-540 check valves (May be used to extend the above header to five inlets)GMSM-HVR-580-04S Simplex MANIFOLD with four CGA-580 header valves, right-hand side, staggered layoutNumber of Cylinders5" Centers All Gases10" Centers All Gases except Fuel Gases 13" Centers Fuel Gases10" Centers All Gases except Fuel GasesGAS MANIFOLD ASSEMBLIES.

10 Simplex MANIFOLD headers are a single unit design manufactured from free cutting brass bar stock. This design eliminates all brazed joints. Each unit is tested to times working pressure and cleaned for oxygen service per MANIFOLD headers are shipped complete with master valve and CGA inlet connections. Headers are ordered in 2 or 3 cylinder configurations and connected together to arrive at the desired number of cylinders. Four and six cylinder version are also available in a crossover arrangement. All modular headers feature 5 center-to-center spacing between inlets.


Related search queries