GE EST Fire & Life Safety Security Control Panels - Edintel

GE EST fire & life Safety Security Control Panels Overview Features The GE EST io64 intelligent life Safety system offers the power of Comes standard with one loop that supports up to 64 intelligent high-end intelligent processing in a configuration that delivers an devices of any type and two Class B uncomplicated solution for small to mid-sized applications. With Supports Signature Series modules and detectors intelligent detection, electronic addressing, automatic device map- ping, optional Ethernet connectivity, and a full line of easily-config- Form C for ALarm and Trouble, Form A for Supervisory ured option cards and modules, this flexible system offers advanced Electronic addressing with automatic device mapping features that benefit building owners and contractors alike. Optional Ethernet port for diagnostics, programming and variety The io64 provides one Class B analog device loop that supports of system reports up to 64 device addresses, and two Class B Notification Applianc e Two programmable switches with LEDs and custom labeling Circuits (NACs).

Data Sheet 85005-0131 Issue 1 Not to be used for installation purposes. Page 1 of 8 GE Security EST Fire & Life Safety Control Panels Overview The GE EST iO64 intelligent life …

Tags:

  Security, Control, Safety, Life, Fire, Panels, Io64, Fire amp life safety security control panels

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GE EST Fire & Life Safety Security Control Panels - Edintel

1 GE EST fire & life Safety Security Control Panels Overview Features The GE EST io64 intelligent life Safety system offers the power of Comes standard with one loop that supports up to 64 intelligent high-end intelligent processing in a configuration that delivers an devices of any type and two Class B uncomplicated solution for small to mid-sized applications. With Supports Signature Series modules and detectors intelligent detection, electronic addressing, automatic device map- ping, optional Ethernet connectivity, and a full line of easily-config- Form C for ALarm and Trouble, Form A for Supervisory ured option cards and modules, this flexible system offers advanced Electronic addressing with automatic device mapping features that benefit building owners and contractors alike. Optional Ethernet port for diagnostics, programming and variety The io64 provides one Class B analog device loop that supports of system reports up to 64 device addresses, and two Class B Notification Applianc e Two programmable switches with LEDs and custom labeling Circuits (NACs).

2 Optional Class A device wiring is available with the use of a module. Supports Genesis horn silence over two wires and UL 1971- compliant strobe synchronization This life Safety system features an attractive design that fits with Optional Class A wiring any decor. Its distinctive doorfront offers a contemporary look that's available with red or silver finishes. All LED indicators and its large Supports up to eight serial annunciators, (LCD, LED-only, and backlit display remain easy to see at all times. graphic interface). The io64 supports a wide range of accessories and related equip- Can use existing wiring for most retrofit applications ment, including: Upload/download remotely or locally Signature Series intelligent modules, detectors, and bases Two-level maintenance alert reporting R-Series remote annunciators Pre-alarm and alarm verification by point option cards that expand system capacity and extend system Adjustable detector sensitivity capabilities.

3 4 x 20 character backlit LCD display io64 Intelligent life Safety System Data Sheet 85005-0131 Issue 1. Not to be used for installation purposes. Page 1 of 8. Application Operation The io64 life Safety system is a powerful intelligent solution for small The front panel provides to mid-sized buildings. Advanced analog technology delivers the ben- an easy-to-use operator's efits of flexible system installation, while a clean and easy-to-opera- interface, as well as all the tate user interface makes panel operation and system maintenance necessary controls for front quick and intuitive. panel programming. A large back-lit 80-character LCD. The smart choice displays system status, Signature Series electronic addressing eliminates the tedium of event details, and program- setting dipswitches, and automatic device mapping ensures that ming prompts. Large tactile each device resides on the system at its correct location.

4 Mean- Control buttons are easy to while, innovative programming features allow the system designer see in low light conditions, to customize powerful built-in features to precisely suit the needs of and bright multi-color LEDs the building owner. offer at-a-glance status indication. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits The io64 is particularly well-suited to retrofit applications. All connections are made over standard wiring no shielded cable Control buttons required. This means that in most situations existing wiring can be used to upgrade a legacy Control panel to iO-Series technology Button Description without the expense or disruption of rewiring the entire building.

5 System Reset Initiates a system reset. ACK/Panel Silences the panel and remote annunciators during Silence an active trouble, supervisory, or alarm event and Signals with a difference acknowledges new event activations. io64 NACs are configurable to fully support the advanced signal- Signal Silence Alarm mode: Silences active notification appliances. ing technology of GE Genesis and Enhanced Integrity notification Pressing Signal Silence a second time turns NACs back on. appliances. These devices offer precision synchronization of strobes Drill Initiates a drill confirmation. Pressing drill a second time to UL 1971 standards. For Genesis devices, enabling this feature turns off the drill function. allows connected horns to be silenced while strobes on the same Remote Dialer: Disables or enables dialer. two-wire circuit continue to flash until the panel is reset. Disconnect Dialer set to modem only: Disables or enables the common alarm relay.

6 Clear-cut remote annunciation Left arrow Display mode: Moves the cursor to the left. Remote annunciation is a strong suit of the io64 . Up to eight an- Menu mode: Toggles between programming selections. nunciators can be installed on a single system. Compatible annun- Right arrow Display mode: Moves the cursor to the right. ciators include a range of LED and LCD models that provide zone or Menu mode: Retrieves a programming option's sub menu point annunciation, as well as common Control capabilities. and toggles between a programming option's selections. Up arrow Display mode: Advances to the previous event. The io64 also supports graphic annunciation with optional RA Menu mode: Moves the cursor up. Graphic Annunicator interface modules. Each interface provides Down arrow Display mode: Advances to the next event. common Control , indicators, and 32 LEDS. Consult the Ordering Menu mode: Moves the cursor down.

7 Information section for details. Enter Display mode: Displays selected event details. Menu mode: Retrieves a programming option's sub A complete line of accessories menu or jumps to the Save function in the menu. Entry mode: Enters the selected data into the system. The io64 life Safety system is supported by a complete line of intelligent detectors, modules and related equipment. Consult the Cancel Display mode: Exits the detailed information display. Menu mode: Exits the current menu level. Ordering Information section for details. Entry mode: Clears the current entry. Menu Display mode: Enters the menu mode Menu mode: Exits menu mode Space Enters a space, such as a space between words. Alphanumeric Entry mode: Pressing a button once enters the number keypad on the button. Pressing the button twice enters the secondary value. Programmable These buttons can be programmed to Control or enable/.

8 Buttons disable a device, zone, or Panel NAC. The buttons can be labeled with a slip-in insert. Data Sheet 85005-0131 Issue 1. Not to be used for installation purposes. Page of 8. System LEDs Panel Operation Options LED Description Language English or French fire Alarm Red LED. Flashes when there is an active alarm Marketplace or Canada event on any loop. On steady once acknowledged. AC fail delay Off: Off-premise notification of an AC power failure is Trouble Yellow LED. Flashes when there's a fault with a immediate. monitored circuit or system component or when a 1 to 15 hours: Delays the off-premise notification of an AC power failure by the time period selected. circuit is disabled. On steady once acknowledged. Zone resound On: NACs resound each time a device in the zone Supv Yellow LED. Flashes when there is an active superviso- goes into alarm even if they were silenced ry event on any loop.

9 On steady once acknowledged. Off: Inhibits the NACs from turning on again (after AC Power Green LED. On when the panel has AC power. they were silenced) when a second device in the zone Disable Yellow LED. Double-flashes when there is a dis- goes into alarm. abled circuit, alarm relay, or remote annunciator. Reset inhibit after Off: Panel reset is operational immediately. Ground Fault Yellow LED. On steady during an active ground fault. NACs turn on 1 minute: Panel reset is inhibited for one minute. Test Yellow LED. Flashes when performing an audible Auto signal Off: Allows immediate silencing of signals from an walk test. Steady indicates a silent test. silence off-normal condition using the Signal Silence button Monitor Yellow LED. Flashes when there is an active monitor 5 to 30 minutes: Delays the silencing of signals from event on any loop. On steady once acknowledged. an off-normal condition by disabling the Signal Silence button for the time period selected.

10 Service Yellow LED. Indicates that detector needs servicing. Day start Start time for daytime sensitivity Detector Signal Yellow LED. On steady indicates that NAC circuits Night start Start time for nighttime sensitivity Silence are turned off but the panel is still in alarm. Date : MM/DD/YYYY. Canada: DD/MM/YYYY. Remote Yellow LED. On steady indicates that the dialer Mapping Disabled: Device mapping is not available Disconnect is disabled or that the alarm relay is enabled or Enabled: Device mapping is available disabled when the dialer is set to modem only. LCD banner Banner text for line one and line two. Each line is Drill Yellow LED. Indicates that the panel is in drill. capable of up to 20 characters. Reset Yellow LED. Indicates that the panel is resetting. Event notification Zone: When a device is a member of a zone, only the Panel Yellow LED. Indicates that the panel has been zone information is sent to the LCD display, LEDs, Silence silenced during an active trouble, supervisory, or printer, and dialer.