Example: bachelor of science

General Models SE100MJ/NJ and Specifications …

GeneralSpecifications<<Contents>> <<Index>>Solution to your profitabilityADMAG SE is the Safe and Easy magnetic flowmeterwhich makes your job simple and effective. You willincrease the productivity and profitability. Theinstallation, operation, and maintenance are all safeand SE is equipped with a dual cavity housingproviding ease of wiring while isolating the electronicsfrom the environment. It is also prepared with HARTor BRAIN communication as standard and its lightweight makes installation easy .nFEATURESn High Reliability Based on Field Proven Technology Proven Construction Long Term Durabilityn Compliance to World Market Requirements General Safety CE mark, C-Tick mark Explosion Proof ISO Standardn High Accuracy ( of flow rate)n Easy Operation and Maintenance Parameter Setting with Touch Control Self Diagnostics Light Weight and Easy Installation Face to Face Length conform to ISO Standard(Flange Type)n Easily Visible Display The Large Visible LCD Paneln Communication Capability HART or BRAIN as standar

General Specifications <<Contents>> <<Index>> Solution to your profitability ADMAG SE is the Safe and Easy magnetic flowmeter which makes your job simple and effective.

Tags:

  Specification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of General Models SE100MJ/NJ and Specifications …

1 GeneralSpecifications<<Contents>> <<Index>>Solution to your profitabilityADMAG SE is the Safe and Easy magnetic flowmeterwhich makes your job simple and effective. You willincrease the productivity and profitability. Theinstallation, operation, and maintenance are all safeand SE is equipped with a dual cavity housingproviding ease of wiring while isolating the electronicsfrom the environment. It is also prepared with HARTor BRAIN communication as standard and its lightweight makes installation easy .nFEATURESn High Reliability Based on Field Proven Technology Proven Construction Long Term Durabilityn Compliance to World Market Requirements General Safety CE mark, C-Tick mark Explosion Proof ISO Standardn High Accuracy ( of flow rate)n Easy Operation and Maintenance Parameter Setting with Touch Control Self Diagnostics Light Weight and Easy Installation Face to Face Length conform to ISO Standard(Flange Type)n Easily Visible Display The Large Visible LCD Paneln Communication Capability HART or BRAIN as standardn Cost-effectiveNote: HART is a registered trademark of the HARTC ommunication SPECIFICATIONSnMagnetic Flow Converter* Note.

2 For Models with no setting switches, a hand-heldterminal is necessary to set parameters.**Note:Pulse output, status output and alarm output usethe commom terminals, therefore these functionsare not used at the same method: Pulsed DC excitationOutput Signal:Current Output: 4 to 20 mA DC (Load resistance600 ohm maximum).Transistor Contact Output: Pulse, alarm or statusoutput selected by parameter setting(Contact rating: 30 V DC, 200mA)Communication :HART or BRAIN (Superimposed on the 4 to 20 mADC signal)Conditions of Communication Line:Load Resistance: (including cable resistance)HART:230 to 600 ohm, depending on q'ty offield devices connected to the loop(multidrop mode)BRAIN:250 to 600 ohmLoad Capacitance: F maximumLoad Inductance: mH maximumSpace from Power Line: 15 cm( ft) or more(Parallel wiring should be avoided.)

3 Input Impedance of Receiver Connected to theReceiving Resistance: 10 kohm orlarger (at kHz)( only for HART)Maximum Cable Length: 2 km(6500 ft) (whenpolyethylene - insulated PVC -sheathed control cables (CEV cables)are used)Instantaneous Flow Rate Display Function:Flow rate can be displayed either inengineering units or in percent of span.(for Models with indicator)Totalizer Display Function:Totalized volume in engineering unitscan be displayed by setting a totalizingfactor. (for Models with indicator)Span Setting Function:Volumetric flow setting is available bysetting volume unit, time unit, flow ratevalue and flow tube Unit: gallon(US), m3, l, cm3, barrel (= )Velocity Unit: ft, mTime Unit: sec.

4 , min., hour, dayFlow Tube Size: inch, mmData Security During Power Failure:Data storage in EEPROM - no back-upbattery SE100MJ/NJ andSE200MJ/NJIntegral TypeMagnetic FlowmeterYokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanTel.: 81-422-52-4443 Fax.: 81-422-52-2018GS 1E10B1-01 EGS 1E10B1-01E Copyright June 1997(YK)6th Edition Jun. 1999(YK) Rights Reserved. Copyright 1997, Yokogawa Electric Corporation<<Contents>> <<Index>>GS 1E10B1-01E6th Edition ,1999-00 Damping Time Constant:Settable from second to 200seconds. (63% response time)Pulse Output Function:Scaled pulse can be outputted bysetting a pulse Width: Duty 50% or fixed pulse width( , 1, 20, 33, 50, or 100 ms) - Rate: to 1000pps (when pulseoutput function is selected.)

5 Status Output Function:One of the followings is selected byparameter setting. Auto 2 Ranges Status Output:Indicates the selected range for auto 2ranges function. Forward and Reverse Status Output:Indicates the flow direction for forwardand reverse flow measurement mode. Totalization Status Output:Indicates that the internal totalized valueexceeds the set value. Low Limit Alarm:Indicates that flow rate is under the lowlimit set Output Function:Indicates that an alarm occurs(Normal close Fixed).Self Diagnostics Function:Converter failure, flow tube failure,erroneous setting, etc. can be diag-nosed and displayed (for Models withindicator).Touch Control:Parameter setting operation by infraredswitches.

6 (for Models with indicator andsetting switches)Electrical Connection:ANSI 1/2 NPT female, DIN , ISO M20 x female, JIS G1 Connection: M4 size screw Material: Aluminum :Polyurethane corrosion-resistantcoating. Deep sea moss green ( ).Protection: IP67, NEMA 4 XMagnetic Flow TubeProtection: IP67, NEMA in mm (inch):15 ( "), 25 (1"), 40 ( "), 50 (2"), 80 (3"), 100(4"), 150 (6"), 200 (8")Coating:Polyurethane corrosion-resistant coating,Deep sea moss green ( ) All sizes of carbon steel flange type 150 and 200 mm of wafer type No coating 15 to 100 mm of stainless steelflange type 15 to 100 mm of wafer typeFlow Tube Material:Size 15 to 100 mm ( " to 4")Housing: Stainless steel (15 mm: SCS11, 25 to100 mm: SUS304)Flange: Carbon steel (SS400) or stainless steel(SUS304)Pipe:Stainless steel (15 to 25 mm: SCS13, 40to 100 mm: SUS304)Size 150 to 200 mm(6" to 8")Housing: Carbon steel (SPCC)Flange: Carbon steel (SS400)Pipe.

7 Stainless steel (SUS304)Wetted Part Material:Lining:Fluorocarbon PFAE lectrode: Stainless steel (SUS316L), Hastelloy C(equivalent to Hastelloy C-276),Titanium, Tantalum, Platinum-Iridium,Tungsten Ring:Stainless steel (SUS316), Hastelloy C(equivalent to Hastelloy C-276),Titanium, PFA lining + Earth electrode*.*Earth Electrode: Tantalum, Construction: External insertion : Hastelloy is a registered trademark ofHaynes International AREA CLASSIFICA-TION (Except 24V power supply version)CENELEC (KEMA):ATEX DirectiveNo. KEMA 98 ATEX 3230 EEx dm[ia] II C ;Group II Category2 GElectrode circuit Um: 250 V ac/dcExcitation Circuit: 41 Vmax. 6 HzTemp. ClassT6T5T4T3 Process CEnclosure : IP67FM:Explosion proof for Class I, Division 1 and Division2, Groups A, B, C & proof for Class II/III, Division 1 andDivision 2, Groups E, F& factory safe electrodes for Class I, Division 1,Groups A,B,C& circuit Vmax.

8 : 250 V : T6 Enclosure: NEMA 4 XNote: Installation shall be in accordance with the manufacturer's instructions and the National Electric Code, ANSI/NFPA-70 There is no need of the conduit seal for both of Division 1 and 2 hazardous locations because this product is sealed at : (now preparing)Explosion proof for Class I, Division 1 and Division2, Groups B, C & proof for Class II/III, Division 1 andDivision 2, Groups E, F& factory safe electrodes for Class I, Division 1,Groups A,B,C& circuit Vmax.: 250V ac/dcTemp. ClassT6T5T4T3 Process CEnclosure: Type 4 Note: There is no need of the conduit seal for Division2 hazardous location because this product issealed at : (now preparing)3<<Contents>> <<Index>>All Rights Reserved.

9 Copyright 1997, Yokogawa Electric CorporationGS 1E10B1-01E6th Edition ,1999-00nSTANDARD PERFORMANCEA ccuracy:Size in mm(inch)15 to 200( to 8)Span in m/s(ft/s) to 1(1 to 3)1 to 10 (3 to 33) of of span (at indications below 50% of span) of flowrate (at indications 50% of span or more) of flowrate (minimum 1mm/s)Maximum Power Consumption:10W ( for combination of flow tube andconverter)Insulation Resistance: 100M ohm between power terminalsand ground terminal at 500 V DC. 100M ohm between power terminalsand each output terminal at 500 V DC. 20M ohm between each output terminaland ground terminal at 100 V Voltage: 1500 V AC between power terminalsand ground terminal for 1 minute.

10 ( for -A1/-A2 power supply) 500 VAC between power terminals andground terminal for 1 minute.( for -D1 power supply)Safety Requirement Standard:1EC 1010 EMC conformity standard:EN55011 Class A, Group 1EN50082-2AS/NZS 2064: 1997nNORMAL OPERATING CONDITIONA mbient Temperature: -20 to 60 C (-4 to 140 F)Ambient Humidity: 5 to 95%RH (no condensation)Rated Power Supply Voltage:100 V AC Version: 100/115 V AC (Range80 to 127 V AC) ,230 V AC Version: 200 to 240 V AC(Range 180 to 264 V AC)24 V DC/AC Version: (Range to DC/AC)Power Supply Frequency for AC version: 47 to 63 HzSupplied Power and Cable Length for 24V DCversion:Fluid Conductivity: 5 S/cm or largerMeasurable Flow Rate Range:Fluid Temperature and Pressure.