Transcription of GEOTECH INSTRUMENTS, LLC
1 SMART-24 SERIES DATA DIGITIZER MODEL SMART-24D DATA RECORDER MODEL SMART-24R STRONG MOTION DATA RECORDER MODEL SMART-24A BOREHOLE DATA DIGITIZER MODEL SMART-24B User s manual Version manual SUBJECT TO CHANGE WITHOUT NOTICE October, 2011 GEOTECH INSTRUMENTS, LLC Copyright 2003-2011 GEOTECH Instruments, LLC. All rights are reserved, including those to reproduce this manual or parts thereof in any form without permission in writing from GEOTECH Instruments, LLC. This manual is protected by United States copyright law (Title 17 United States Code). Unauthorized reproduction and/or sales may result in imprisonment of up to one year and fines of up to $10,000 (17 USC 506).
2 Copyright infringers may be subject to civil liability. For information relating to other GEOTECH Instruments products and manuals, inquires may be addressed to: GEOTECH INSTRUMENTS, LLC10755 Sanden Drive, Dallas, Texas 75238-1336 Phone: 214 221-0000 Fax: 214 343-4400 Web: SMART-24 Series User s manual i Revision History Date ECN Rev Initials Description 07/10/03 Preliminary Release 05/03/04 First Release 09/14/04 Updated cable diagrams 10/05/04 Updated cable diagrams 10/28/04 SMART Series Command & Setup Protocol ICD Version PBA Major update 11/02/05 PBA, DM.
3 MR Firmware and SMART-24A Updates 12/06/05 PBA Fully incorporated latest firmware and SMART-24A updates01/09/07 Updated cable diagrams 05/16/07 Updated cable diagrams 08/15/08 WH, MR SMART-24B Updates 04/20/09 SMART-24B and SMART-24A Updates 08/26/10 MR Firmware Updates 11/2/10 MR Minor Updates 10/28/11 LO,MR New ADC versions 05, 06 SMART-24 Series User s manual ii This page intentionally left blank.
4 SMART-24 Series User s manual iii CONTENTS 1. GENERAL INFORMATION .. 1 PURPOSE OF EQUIPMENT .. 1 DESCRIPTION OF EQUIPMENT .. 2 4 Controls, Indicators and Connectors .. 4 Setup and 5 Updates .. 6 SUPPLIED EQUIPMENT ..6 2. 1 DATA ACQUISITION .. 1 Number of Inputs .. 1 Input 1 Input 1 Input 1 Common Mode Rejection .. 1 Input Gain .. 2 SMART-24A Internal 2 Digitizer .. 2 Anti-alias Filter .. 2 Intermodulation 2 Total Harmonic Distortion ..2 Output Sample 2 Noise .. 3 Dynamic 3 Channel Sampling Skew ..3 Calibration .. 3 3 Type .. 3 Stability.
5 3 Data Sample Time Tag Accuracy .. 3 GPS Duty Cycle .. 4 ACQUISITION MODES ..4 Continuous Recording .. 4 Event Triggered Timed Window 4 DATA 4 Type .. 4 Recording Format .. 4 INTERFACES .. 4 Communications .. 4 GPS .. 5 Analog Input .. 5 Power .. 5 LCD Display .. 5 PCMCIA .. 5 SMART-24 Series User s manual iv Other I/O .. 5 GENERAL .. 5 Firmware .. 5 Field Upgrades .. 6 Setup and 6 Utility 6 State of 6 POWER .. 6 Input .. 6 Power 6 SMART-24A Internal Battery .. 7 7 7 7 7 Operating Temperature .. 7 Humidity .. 7 OPTIONS .. 7 Non-removable Data 7 ADC Board.
6 7 Communications .. 8 3. INSTALLATION .. 1 GENERAL .. 1 UNPACKING AND 1 FUNCTIONAL CHECKOUT .. 1 MOUNTING A SMART-24 SERIES 3 Location .. 3 3 CONTROLS, INDICATORS AND 10 ON Touch Pad 11 OFF Touch Pad Button .. 11 USER Touch Pad Button ..11 LCD Display .. 11 CH 1-3 & CH 4-6 Connectors .. 12 Power 15 Input/Output 16 GPS Connector .. 19 GENERAL INSTALLATION .. 19 Power Connections .. 19 Analog Input Connections ..20 GPS Connections .. 20 Input/Output Connections .. 21 SITE SPECIFIC 21 4. OPERATION .. 1 CONNECTION AND POWER UP .. 1 Power Connection .. 1 GPS 1 Sensor Connection.
7 1 Communications Connection .. 1 Power Up .. 3 Power Down .. 3 General Operation .. 4 SMART-24 Series User s manual v LCD DISPLAY 4 Bootup Screens .. 4 Operational Screens .. 6 SERIAL PORT OPERATION .. 13 Serial ASCII Character Command Operation .. 14 Serial PPP Server Operation ..16 Serial PPP Client Operation .. 27 USGS Real Time Data (RTD) 37 10/100 BASE-T ETHERNET OPERATION .. 40 TCP/IP 40 Factory Default Settings .. 41 TCP/IP Over Ethernet Operation .. 41 TCP/IP Over Serial PPP 43 SMART Series Software Operation Over 43 Telnet Operation .. 45 FTP Server Operation.
8 55 HTTP Operation .. 59 BOOTLOADER OPERATION .. 71 Power Up and 71 Main Command Menu - PROGRAM .. 73 Main Command Menu - ERASE .. 76 Main Command Menu - FWSTAT .. 77 Main Command Menu - HWSTAT .. 77 APPLICATION FIRMWARE OPERATION .. 78 GPS .. 78 ADC .. 78 Serial Ports .. 79 TCP/IP 79 Real Time Data Servers .. 79 Command State of 80 Calibration .. 81 Commands .. 81 Disk Drives .. 81 Data File Recording .. 83 File Conventions .. 85 Fortezza PCMCIA APPLICATION FIRMWARE 100 Bootloader Update Mode .. 100 Application TCP/IP Update Mode .. 100 5. MAINTENANCE.
9 1 6. BOREHOLE DATA DIGITIZER MODEL SMART-24B .. 1 1 1 Controls, Indicators and Connectors .. 2 EXTERNAL CONNECTIONS .. 4 Analog Input/Output .. 4 Digital 6 8 8 8 8 SMART-24 Series User s manual vi APPENDIX A. SMART-24 SERIES CABLE DIAGRAMS .. 1 APPENDIX B. SMART-24 SERIES FIRMWARE 1 APPENDIX C. SMART-24 SERIES COMMAND & SETUP 1 General Information 1-1 Section 1 1.
10 GENERAL INFORMATION PURPOSE OF EQUIPMENT GEOTECH Instruments SMART-24 Series product line encompasses a wide range of data acquisition instrumentation with a common design used for digitizer, portable data recorder and strong motion recorder instruments (the all-in-one solution). This manual describes the operation and use of GEOTECH Instruments high resolution Data Digitizer Model SMART-24D , portable Data Recorder Model SMART-24R and Strong Motion Data Recorder Model SMART-24A instruments. Figure 1-1. SMART-24 Series Instrument The SMART-24D is a low-power Data Digitizer designed to acquire near real time, high quality data from remote sites and in harsh environments.