Get Your Fill. - Bio-Rad

Get your full line of empty chromatography columns and PurificationBio-Scale columnsEcono-Pac columnsEcono-Column columnsApplicationRequirementHigh-resolu tion columnProduct LinePressure Range, psiVolume Range, mlBest Used With0 1, 22 High-performance systemGeneral-purpose glass column0 1,374 Low-pressure or gravity-flow system General-purpose disposable plastic column0 20 Low-pressure or gravity-flow system General-purpose disposable plastic column0 2 Low-pressure or gravity-flow system General-purpose disposable plastic column 0 bucket centrifugeGeneral-purpose disposable plastic column 0 microcentrifugeBio-Rad s Empty Column Line Is Packed With OptionsFrom low-pressure chromatography to high-resolution separations, we offer a comprehensive line of empty chromatography columns, accessories, and media to meet your specific chromatographic needs.

Disposable Low-Pressure Chromatography Columns All of Bio-Rad’s disposable chromatography columns are made of chemically compatible polypropylene, have a 30 µm hydrophilic bed support, are fully autoclavable, and can be

Tags:

  Your, Fill, Autoclavable, Get your fill

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Get Your Fill. - Bio-Rad

1 Get your full line of empty chromatography columns and PurificationBio-Scale columnsEcono-Pac columnsEcono-Column columnsApplicationRequirementHigh-resolu tion columnProduct LinePressure Range, psiVolume Range, mlBest Used With0 1, 22 High-performance systemGeneral-purpose glass column0 1,374 Low-pressure or gravity-flow system General-purpose disposable plastic column0 20 Low-pressure or gravity-flow system General-purpose disposable plastic column0 2 Low-pressure or gravity-flow system General-purpose disposable plastic column 0 bucket centrifugeGeneral-purpose disposable plastic column 0 microcentrifugeBio-Rad s Empty Column Line Is Packed With OptionsFrom low-pressure chromatography to high-resolution separations, we offer a comprehensive line of empty chromatography columns, accessories, and media to meet your specific chromatographic needs.

2 As with all products from Bio-Rad , each is manufactured under the strictest quality control standards. You can expect only the highest quality with every purchase you Column Selection GuideBio-Rad also offers process-scale chromatography columns. Contact your local Bio-Rad office for more columnsBio-Spin columnsMicro Bio-Spin columnsLow-Pressure Chromatography ColumnsBio-Rad s Econo-Column line offers a complete range of versatile columns for low-pressure chromatography applications. A wide range of glass columns, jacketed columns, flow adaptors, reservoirs, and other chromatography essentials offers an unbeatable combination of performance, reliability, and cam (1 = loose, 2 = sliding seal, 3 = fixed seal)Delrin housing (snaps onto Econo-Column columns, jacketed Econo-Column columns, and Econo-Pac columns)Reliable ethylene-propylene sealReplaceable porous polymer bed supportReplaceable flexible silicone tubing ( mm lD) with replaceable female Luer- Lok fittingFlow AdaptorStandard Econo-ColumnJacketed Econo-Column(Open-Ended)

3 500 ml or 1 Lreservoir250 ml reservoirGraduated volume markingsCap with male Luer-Lok fittingColumn FunnelGlass ReservoirGlass Econo-Column ColumnsEcono-Column chromatography columns are the standard in high-quality, affordable low-pressure chromatography Available in lengths from 5 to 170 cmn Inner diameter from to cmn Volumes from 0 to 1,374 mln Operating pressure to 1 psin Fully autoclavable and NaOH compatibleJacketed Econo-Column ColumnsJacketed Econo-Column columns are ideal for chromatographic applications requiring temperature control, such as thermal chromatography of DNA separation using Bio-Gel hydroxyapatite Integral water jacket for cooling or heatingn Open-ended column delivered with 2 flow adaptorsn Standard column delivered with 1 flow adaptor Flow AdaptorsFlow adaptors significantly improve column performance by eliminating head space above the gel bed and by protecting the gel bed from disruption during sample Available for , , , and cm columnsn Fit Econo-Column chromatography columns, jacketed Econo-Column chromatography columns.

4 And Econo-Pac columns*Column Funnel and Glass ReservoirsEcono-Column funnel and reservoirs are ideal for column packing, loading diluted samples, or delivering large volumes of Reservoirs available for 500 ml and 1 L capacitiesn Reservoirs fit , , , and cm ID Econo-Column columnsn Econo-Column funnel is ideal for packing columns up to cm ID, including Econo-Column columns, Poly-Prep columns, and Econo-Pac columns* Special Econo-Pac flow adaptor allows use with Econo-Pac column ends with male Luer-Lok fittings to simplify tubing connectionsColumn reservoir for manual sample applicationBorosilicate glass barrel clear, inert, durableAccepts accessory funnel, flow adaptors, and reservoirsBed support (28 m)

5 Retains fine particles End caps for stoppingeluent flow or storing packed columnDisposable Low-Pressure Chromatography ColumnsAll of Bio-Rad s disposable chromatography columns are made of chemically compatible polypropylene, have a 30 m hydrophilic bed support, are fully autoclavable , and can be washed with NaOH. All are also available prepacked with selected and Micro Bio-Spin ColumnsBio-Spin and Micro Bio-Spin columns are disposable polypropylene spin columns that can be packed with a variety of chromatography media, such as gel filtration media, to remove dye terminators, clean up DNA primers, remove radiolabels, exchange buffers.

6 Or desalt proteins or Bio-Spin columns hold up to ml of medium and fit in standard swinging bucket centrifugesn Micro Bio-Spin columns hold up to ml of medium and fit in standard microcentrifugesn Both columns fit into standard microtubesn Luer end fitting with snap-off tipn Porous 30 m polyethylene bed support retains fine particlesn autoclavable and NaOH compatiblePoly-Prep ColumnsPoly-Prep columns are convenient gravity-flow chromatography columns for sample preparation and small-scale chromatography applications, including work with radioisotopes and other applications where disposable products are 2 ml bed volume and integral 10 ml reservoirn Porous 30 m polyethylene bed support retains fine particlesn Luer end fitting with snap-off tipn autoclavable and NaOH compatibleEcono-Pac ColumnsEcono-Pac columns are disposable 20 ml polypropylene columns for sample preparation and small-scale chromatography 0 20 ml bed volume and 10 ml reservoirn Porous 30 m polyethylene bed support retains fine particlesn May be fitted with a flow adaptor or used for gravity- flow chromatographyn Luer end

7 Fitting with snap-off tipn autoclavable and NaOH compatiblePoly Column RackThe poly column rack is ideal for using or storing Poly-Prep or Econo-Pac Holds up to 20 Poly-Prep columns or 10 Econo-Pac columnsn Removable tube rack for Poly-Prep column usen Reservoir tray to catch flow-through buffersPoly-Prep ColumnEnd ml bed volumeWorking bed heightPorous 30 mpolyethylene bed support retains fine particlesLuer endfitting with snap-off tipEcono-PacColumnPoly Column RackMicro Bio-Spin cm IDEnd cap10 ml reservoirGraduated volume markings20 ml bed volumeWorking bed heightPorous 30 m polyethylene bed support retains fine particlesSnap-off tip.

8 Luer end fittingBio-Spin ColumnEnd cap10 ml reservoir2 ml bedvolumeWorking bedheightPorous 30 m polyethylene bed support retains fine particlesLuer end fitting with snap-off cmEnd capReservoirWorking ml bed volumeLuer end fitting with snap-off tip3 cm2 cm14 cm9 cm5 cmEasy assembly for packing and cleaningBiocompatible materials for preservation of sample biological activityOptimized design of sample applicator for high-resolution chromatographyFingertight assembly eliminates the need for toolsAdjustable bed support eliminates head spaceTransparent glass tube allows easy bed inspectionResistance to high pressures allows use with most chromatographic mediaMedium-Pressure Chromatography ColumnsThese high-quality columns are compatible with Bio-Rad s BioLogic systems or any medium- to high-pressure chromatography system.

9 The range of columns has been specifically designed to provide high-resolution separation of biomolecules when packed with suitable chromatography MT High-Resolution ColumnsBio-Scale MT columns allow precise sample application and provide the low dead volume required for high-resolution 4 column sizes (2, 5, 10, and 20 ml) allow easy scale-up of purification protocolsn Adjustable bed support eliminates head spacen Fingertight assembly eliminates the need for toolsn Biocompatible material resistant to high pressures allows use of most chromatographic mediaCatalog # DescriptionEcono-Column Selection Packs737-6601 Econo-Column Selection Pack A, 1 each standard column, x 10, 20, 30 cm; x 30, 50 cm; x 20, 50 cm737-6607 Econo-Column Selection Pack B, 1 each standard column, x 20, 30, 50 cm.

10 X 20, 30, 50 cmCatalog # ID, cm Length, cm Cross-Sectional Area, cm2 Maximum Volume, ml Package SizeStandard Econo-Column Jacketed Columns737-6108 15 6 1737-6116 15 12 1737-6131 30 25 1737-6151 50 89 1 Econo-Column Open-Ended Jacketed Column*737-6201 30 25 1 Catalog # Description Column ID, cm Functional Length, cmFlow Adaptors738-0014 Flow Adaptor 1 7738-0015 Flow Adaptor 1 14738-0016 Flow Adaptor 1 14738-0017 Flow Adaptor 1 14738-0018 Flow Adaptor** 1 14738-0019 Econo-Pac Flow Adaptor Flow Adaptor Replacement Parts738-0022 Flow Adaptor Maintenance Kit, for cm flow adaptor, includes 2 bed supports, 2 O-rings738-0024 Flow Adaptor Maintenance Kit, for cm adaptor with cam mechanism, includes 10 bed supports, 5 O-rings738-0025 Flow Adaptor Maintenance Kit, for cm adaptor with cam mechanism, includes 10 bed supports, 5 O-rings 738-0027 Flow Adaptor Maintenance Kit, for cm adaptor with cam mechanism, includes 10 bed supports, 5 O-rings Funnel and Reservoirs 731-0003 Econo-Column Funnels, 250 ml, 5737-9112 Econo-Column Reservoir, 500 ml737-9113 Econo-Column Reservoir, 1 LCatalog # Description Volume, ml Column Pressure Limit.