Transcription of GEYSERWISE INSTRUCTION MANUAL
1 GEYSERWISE INSTRUCTION MANUAL GEYSERWISE MAX DELTA T ALL IN ONE HOT WATER MANAGEMENT Before operating and installation, carefully read all instructions. Do not discard this MANUAL . INDEX 1. Package Contents 1 2. About this MANUAL 1 Applicability 1 Users 1 3. Safety 1 Proper usage 1 Improper usage 1 Dangers during installation 2 Detecting faults 2 Exclusion of liability 2 4. Uses, Characteristics and technical information 3 Uses 3 Characteristics 3 Technical information 3 5. Installation 4 Installation notice 4 Diagram power supply 4 Terminal plan and wiring diagram 5 Connector plan 5 12 V battery plan 6 Installation: geyser and thermosiphon solar system 6 Installation: split pump system with 220V pump 6 Installation: split pump system with 12V pump, PV panel and back-up battery 7 6.
2 Operation 7 Display 7 Setting the water temperature 7 Adjusting day of the week 9 Adjusting the time 9 Setting timers 9 Power save mode 11 Holiday /mode 11 Bypassing the timers 12 Check energy usage in hours 12 Useful tips 12 7. Operation: thermosiphon solar system 12 8. Operation: split pump system 13 9. Error codes 14 Summary of error codes 14 E1 14 E2 14 E3 15 E4 15 E5 15 E6 15 E7 15 E8 16 E9 16 10. Sensor R-T table 16 11. Warranty 17 12.
3 Supplier details 17 1 1 PACKAGE CONTENTS 1 x Power supply box 1 x Display unit 1 x Temperature probe with thermal fuse 1 x Collector temperature probe 1 x Water leak detector 2 x Wall plugs and mounting screws 1 x 5m Extension cable 1 x INSTRUCTION MANUAL ADDITIONAL COMPONENTS AVAILABLE TO PURCHASE SEPARATELY Solenoid valve to dump water in overheat situation Reference probe for anode indicator Additional extension cables It is not recommended that the display unit is installed more than 20m from the power supply box. 2 ABOUT THIS MANUAL Applicability This MANUAL describes the installation, operation and maintenance for the GEYSERWISE Max Delta T Hot Water Controller for electric geysers and solar hot water geysers.
4 When installing the remaining components eg. Solar collectors, pumps and geysers, be sure to follow the appropriate installation instructions provided by each manufacturer. Users Installation, maintenance and dismantling may only be performed by trained personnel in accordance with this INSTRUCTION MANUAL and safety instructions. Trained personnel must be familiar with this MANUAL . Use the GEYSERWISE only after first thoroughly reading and understanding this INSTRUCTION MANUAL and the safety instructions. In the event of any ambiguities regarding the installation and operation, consult trained personnel or contact our offices. 3 SAFETY Proper Usage The GEYSERWISE may only be used for systems within the permissible ambient conditions Improper usage The GEYSERWISE must not be operated in the following environments.
5 Outdoors 2 In damp rooms In rooms in which the operation of electrical and electronic components may be dangerous Dangers during Installation The following dangers exist during installation of the GEYSERWISE and during operation (in case of incorrect installation) Risk of death by electrocution Risk of fire due to short circuit Damage to any of the constructional fire safety measures present in the building due to incorrectly installed cables Damage to the GEYSERWISE and connected devices due to improper ambient conditions, inappropriate power supply and incorrect installation Therefore all safety regulations apply when working on the mains supply Be sure to comply with the specified degree of protection.
6 Factory labels and markings may not be altered, removed or rendered unreadable Before connecting the GEYSERWISE , make sure that the power supply matches the specifications on the type plate Make sure that all devices which are connected to the GEYSERWISE conform to the technical specifications of the GEYSERWISE All work on an open GEYSERWISE must be performed with the mains supply disconnected Protect the controller against overloading and short-circuiting Detecting Faults Check the display regularly In case of faults, isolate the cause As soon as it becomes evident that safe operation is no longer possible, remove the GEYSERWISE from the mains supply immediately Have trained personnel remedy the fault Exclusion of liability The manufacturer cannot monitor the compliance to this MANUAL as well as the conditions and methods during installation and operation.
7 Improper installation of the system may result in damage to the property and, as a result, in bodily injury. Therefore, we assume no responsibility for loss, damage or costs which result from or are in any way related to incorrect installation, improper operation, incorrect execution of installation work and incorrect usage and maintenance. The manufacturer reserves the right to make changes to the product, technical data or assembly and operating instructions without prior notice. 4 USES, CHARACTERISTICS AND TECHNICAL INFORMATION 3 Uses GEYSERWISE is designed to manage your hot water needs to your best advantage from both an energy and economical point of view.
8 It uses professional techniques and the control system is managed by computer micro processor. Characteristics Clear display of water temperature, time, day, heating mode, malfunction conditions. Auto or MANUAL heating. Easy temperature setting to your requirements (30 C - 65 C) Factory default is 55 C. Four different temperature settings Daily programmable timer with four time settings. Default settings to coincide with South African municipal load control programs. Battery back up in event of power failure. Multiple protection functions: Dry heat, heat failure, earth leakage, probe failure overheat, water leak. Error conditions alert by error code E1 to E9. Technical Parameters Operating voltage 230 VAC / 50HZ.
9 Main Relay contact rating 30 AMP (Max 4KW). Secondary relays pump and solenoid 5 Amp. Operating voltage range 160V 250V AC. Earth leakage protection at 25MA action time 0,1 second. Temperature display range 0 - 99 C ( -5 when below -5 C OE when above 99 C). Temperature setting ranges 30 - 65 C. Maximum temperature 85 C. Heat failure when increase at a rate of less than 4 C per hour. Thermal Cutout 90 C Dry Heat detection Empty Cylinder. Temperature tolerance 2% Temperature differential setting 1 C. Switching differential 6 C. 2nd temperature probe for solar Solar differential 7 C Temperature probe failure detection for both collector and tank Temperature probe range for geyser is -30 to + 130 C.
10 Temperature probe range for collector is -30 to + 260 C Isolate both L + N when in off state. Collector antifreeze protection 4 Anode depletion indicator Home alarm interface 5 INSTALLATION Installation Notice Isolate electrical supply before installation Installation should be by a suitably qualified person only The grounding (earth) must be continuous Install in a dry location If a 3 pin 16 Amp plug top is used heating element should not exceed Kw Diagram - Power Supply Terminal Plan and Wiring Diagram 5 Connector Plan 6 12V Battery Plan It is recommended that a 4 AH 12 V battery together with a 10 Watt PV panel is used Installation.