GFR3100 Heated Safety Station with Eyewash, Top …

Freeze-Resistant Units FF GFR3100 Heated Safety Station with Eyewash, Top Inlet, Rated for Class I, Division 2 Environment Application: Electric heat-traced stations prevent freezing even in extreme conditions. Thermostat regulated units are Heated by self-limiting heat-tracing cable wrapped around internal pipe. Units are intended for cold weather use down to -40 F. See Tempering Valves' section to ensure tepid water compliance with ANSI Heating Cable: Self-regulated with external termination guards. Thermostat activates when internal piping tempera- ture falls below 75 F. FM, UL, and CSA approved for Class I, Division 2, Groups B, C, and D. Electrical System: Unit is fully wired at factory. Junction box and components rated for Class I, Division 2, Groups B, C, and D. Requires 120 VAC single phase power supply. Jacket/Insulation: UV-resistant orange ABS plastic with polyethylene foam insulation. Jacket sections secured with removable stainless steel screws for easy maintenance.

Freeze-Resistant Units Guardian Euipment 31 7 100 TELEPHONE 110 N North ranch St 31 7 101 FACSIILE Chicago IL 0 gesaetycom Listed 11 …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GFR3100 Heated Safety Station with Eyewash, Top …

1 Freeze-Resistant Units FF GFR3100 Heated Safety Station with Eyewash, Top Inlet, Rated for Class I, Division 2 Environment Application: Electric heat-traced stations prevent freezing even in extreme conditions. Thermostat regulated units are Heated by self-limiting heat-tracing cable wrapped around internal pipe. Units are intended for cold weather use down to -40 F. See Tempering Valves' section to ensure tepid water compliance with ANSI Heating Cable: Self-regulated with external termination guards. Thermostat activates when internal piping tempera- ture falls below 75 F. FM, UL, and CSA approved for Class I, Division 2, Groups B, C, and D. Electrical System: Unit is fully wired at factory. Junction box and components rated for Class I, Division 2, Groups B, C, and D. Requires 120 VAC single phase power supply. Jacket/Insulation: UV-resistant orange ABS plastic with polyethylene foam insulation. Jacket sections secured with removable stainless steel screws for easy maintenance.

2 Shower Head: 10" diameter orange ABS plastic with 20 GPM. flow control. Shower Valve: 1" IPS brass stay-open ball valve. US-made with brass ball and PTFE seals. Includes stainless steel actuating arm and 29" stainless steel pull rod. Spray Head Assembly: Freeze-resistant with float-off dust covers and internal flow control. Eyewash Valve: 1/2" IPS brass three-way self-draining stay- open ball valve. US-made with brass ball and PTFE seals. Includes 1/2" NPT port to drain water from spray heads after use. Pipe and Fittings: Schedule 40 galvanized steel. Supply: 1-1/4" NPT female top inlet. Sign: ANSI-compliant identification sign. Quality Assurance: Factory tested prior to shipment. Ships fully assembled and crated. Available Options FF SSH Stainless steel shower head. FF GRN Green ABS plastic shower head and shell. FF HV 240 volt heat tracing. Alarm Options FF TL Heat trace indicator light. Specify desired alarm using fourth digit of model number, as follows: FF SP Scald protection valve.

3 0 No alarm FF FP Freeze protection valve. 1 Single pole, double throw flow switch for remote sensing capability FF ALG Green LED area light. 3 Alarm horn and remote sensing capability FF PS Magnetically activated proximity (MAP) switch. 5 Light and remote sensing capability 7 Alarm horn, light and remote sensing capability Guardian Equipment 312 447 8100 TELEPHONE Listed 8116. Units have been 1140 N North Branch St 312 447 8101 FACSIMILE tested to and comply with ANSI and the Chicago, IL 60642 Uniform Plumbing Code. Freeze-Resistant Units FF GFR3100 Heated Safety Station with Eyewash, Top Inlet, Rated for Class I, Division 2 Environment 1 1/4" NPT UNION INLET. CIRCUIT BREAKER WITH GFCI REQUIRED 9-1/4". (FOLLOW NEC AND LOCAL ELECTRICAL CODES) (235mm). 120V. FROM REMOTE. POWER SOURCE. H N. 23 1/4". TERMINAL BLOCK (591mm) 23 1/2". TERMINAL BLOCK. (597mm). (G). THERMOSTAT HEAT TRACE. 120V POWER. SHOWER CONTROL SCHEMATICS.

4 ABS PLASTIC SHOWER. HEAD WITH 20 GPM. FLOW CONTROL. STAINLESS STEEL. PULL ROD. HEAT TRACED POWER. CONNECTION BOX. 91 3/4". 6 1/2" (2330mm). (165mm). FREEZE- RESISTANT. SPRAY HEADS. STAINLESS. STEEL FLAG. 82 7/8" HANDLE 1/2" NPT. DETAIL "A" 40". UNIVERSAL FLOOR FLANGE (2105mm) (1016mm) MALE DRAIN. POWDER COATED 32 5/8". CAST ALUMINUM (829mm). FLOOR FLANGE. (SEE DETAIL A'). 7/16" MOUNTING SLOTS. ON 7-5/8" BOLT CIRCLE. 9". (229mm). NOTES: 1. FREEZE RESISTANT SPRAY HEAD ASSEMBLY HAS AN INTERNAL FLOW CONTROL. 2. DESIGNED FOR USE IN A CLASS I, DIVISION 2, GROUPS B, C, & D ENVIRONMENT. 3. PEAK HEAT TRACE POWER CONSUMPTION IS 75 WATTS. 4. IN ORDER TO MEET CLASS I, DIVISION 2 REQUIREMENTS, APPROVED CONDUIT AND FITTINGS MUST BE USED. ALL THREADED ELECTRICAL CONNECTIONS MUST HAVE HAZARDOUS LOCATION RATED SEALANT APPLIED TO THREADS. THIS SPACE FOR ARCHITECT/ENGINEER APPROVAL. Emergency Shower/Eyewash Due to continuing product improvement, the information contained in this document is subject to change without notice.

5 All dimensions are 1/4" (6mm). rev. 0417. Guardian Equipment 312 447 8100 TELEPHONE Listed 8116. Units have been 1140 N North Branch St 312 447 8101 FACSIMILE tested to and comply with ANSI and the Chicago, IL 60642 Uniform Plumbing Code.