Transcription of GLASS SYSTEMS - Super Sky
1 GLASS SYSTEMS 8/1/2014 1 Super SKY PRODUCTS ENTERPRISES, LLC 10301 N. Enterprise Drive Mequon, WI 53092 Phone: (262) 242-2000 FAX: (262) 242-7409 GLASS SYSTEMS METAL FRAMED SKYLIGHTS Guide Specification PART 1 GENERAL SECTION INCLUDES A. Engineering and drafting of production documents, including structural calculations of the entire skylight system .
2 B. Fabrication and erection of skylight frames. C. Fabrication and erection of the aluminum gutter system including, when applicable, insulation and pitched liners. D. Applied finish of aluminum extrusions and sheet. E. Skylight GLASS and glazing. F. Skylight related flashings. RELATED SECTIONS A. Structural Steel: Division 05 B. Space Frames: Division 05 C. Metal Fabrications: Division 05 D. Flashing and Sheet Metal: Division 07 E. Glazing: Division 08 F. Glazed Curtain Walls: Division 08 G. Roofing: Division 07 H.
3 Sealants: Division 07 REFERENCES A. Aluminum Association Incorporated (AA):SAS-30 Specifications for Aluminum Structures. B. American Architectural Manufacturers Association (AAMA): 1. : Standard Test Method for Metal Curtain Walls for Water Penetration Using Dynamic Pressure. 2. : Field Check of Metal Curtain Walls for Water Leakage. 3. : Field Check of Water Penetration Through Installed Exterior Windows, Curtain Walls and Doors by Uniform Air Pressure Difference. 4. : Performance Requirements and Test Procedures for Pigmented Organic Coatings on Extruded Aluminum.
4 5. : Specification for High Performance Organic Coatings on Architectural Extrusions and Panels. Super SKY PRODUCTS ENTERPRISES, LLC GLASS SYSTEMS 8/1/2014 26. : Voluntary Guide Specification and Inspection Methods for Integral Color Anodic Finishes for Architectural Aluminum. 7. : Voluntary Guide Specification and Inspection Methods for Clear Anodic Finishes for Architectural Aluminum.
5 C. American National Standards Institute (ANSI): Z -2004- Safety Glazing Materials Used in Buildings -Safety Performance Specifications and Methods of Test. D. American Society for Testing and Materials (ASTM): 1. A193: Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for High Temperature Service. 2. A307: Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength. 3. B209: Specification for Aluminum and Aluminum-Alloy Sheet and Plate. 4. B211: Specification for Aluminum-Alloy Bar, Rod and Wire.
6 5. B221: Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes and Tubes. 6. B316: Specification for Aluminum and Aluminum-Alloy Rivet and Cold-Heading Wire and Rods. 7. C719: Standard Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cycle Movement. 8. C794: Test Method for Adhesion-In-Peel of Elastomeric Joint Sealants. 9. C1036: Specification for Flat GLASS . 10. C1048: Specification for Heat-Treated Flat GLASS -Kind HS, Kind FT Coated and Uncoated GLASS . 11. D395: Test Methods for Rubber Property -Compression Set.
7 12. D412: Test Methods for Rubber Properties in Tension. 13. D1171: Test Method for Rubber Deterioration -Surface Ozone Cracking Outdoors or Chamber (Triangular Specimens). 14. D2240: Test Method for Rubber Property -Durometer Hardness. 15. E283: Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors. 16. E330: Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. 17. E331: Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference.
8 18. E773: Test Method for Seal Durability of Sealed Insulating GLASS Units. 19. E774: Specification for Sealed Insulating GLASS Units. 20. E783: Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors. E. Consumer Product Safety Commission (CPSC): 16 CFR 1201 - Architectural Glazing Standards and Related Material. F. Flat GLASS Manufacturers Association (FGMA): Glazing Manual. G. Insulating GLASS Certification Council (IGCC): Classification of Insulating GLASS Units. system DESCRIPTION A.
9 Design Requirements: 1. Extruded aluminum members with a system of alternate serrations for attachment of exterior GLASS retainers with 1/4-in. x 20 stainless steel screws and snap-on beauty caps. 2. Condensation guttering system integral with skylight framing members for positive drainage of condensation. 3. Flush glazed exterior horizontal joints with field applied structural silicone. 4. Full silicone wet seals along both sides of all exterior GLASS retainers. 5. Optional aluminum rain gutters, with insulation and pitched liners, when applicable.
10 6. Optional 4-sided , or total flushed glazed system , with fully concealed mechanical fasteners and factory applied structural silicone. B. Performance Requirements: 1. Structural Members: Of sufficient sizes to support design loads as prescribed by governing building codes. 2. The deflection of the framing member in a direction normal to the plane of GLASS when subjected to a uniform load deflection test in accordance with ASTM E330, and per the above specified loads, shall not exceed L/175, up to 1-in. maximum, for clear spans under 20-ft.