Example: dental hygienist

Glycerine Bath Type Pressure Gauges

:Gas or liquidSize:60 DIA., 75 DIA., 100 DIA., 150 :Stem Type AType B (Mounting hole)Panel Type D (Mounting clamp, online)Connection:G1/4B (PF), G3/8B (PF), G1/2B (PF),1/2 NPT, 1/4 NPT, R1/4 (PT),R3/8 (PT), R1/2 (PT)* For other connections, please contact parts material:Bourdon tube316 range:0 ~ h 0 ~ ~ 0 h ~ 2 MPaOperating tempereature:5 ~ 40gAccuracy : :Organic glassThe filling up liquid: Glycerine (For range, less than and its compound, Glycerine solution in water is used.)Case material finishing:304 : (Option) Use no oil water(Manufactured and treated in a way that there shall be no oil or water residue at the wetting parts.)Dial scale specified: (Option)Capacity scale, Dual scale , Printed words,Colored circleCaution of operation:It is established the air circulation hole in case upper part to preventindication error by ambient temperature change about pressuregauge / compound Pressure gauge / vacuum gauge less thanmaximum Pressure 1 MPa.

head office & overseas sales dept 1-30-4, higashimagome ohta-ku, tokyo, japan. phone fax e-mail url overseas plants or affiliates: u.s.a., korea, germany

Tags:

  Glycerine

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Glycerine Bath Type Pressure Gauges

1 :Gas or liquidSize:60 DIA., 75 DIA., 100 DIA., 150 :Stem Type AType B (Mounting hole)Panel Type D (Mounting clamp, online)Connection:G1/4B (PF), G3/8B (PF), G1/2B (PF),1/2 NPT, 1/4 NPT, R1/4 (PT),R3/8 (PT), R1/2 (PT)* For other connections, please contact parts material:Bourdon tube316 range:0 ~ h 0 ~ ~ 0 h ~ 2 MPaOperating tempereature:5 ~ 40gAccuracy : :Organic glassThe filling up liquid: Glycerine (For range, less than and its compound, Glycerine solution in water is used.)Case material finishing:304 : (Option) Use no oil water(Manufactured and treated in a way that there shall be no oil or water residue at the wetting parts.)Dial scale specified: (Option)Capacity scale, Dual scale , Printed words,Colored circleCaution of operation:It is established the air circulation hole in case upper part to preventindication error by ambient temperature change about pressuregauge / compound Pressure gauge / vacuum gauge less thanmaximum Pressure 1 MPa.

2 Do up yellow plug of relief valve installation posture limit it to vertical Bath TypePressure GaugesSPECIFICATIONThis is a gauge for exclusive use exposed to vibration. Itsinterior is filled with liquid, preventing vibration of moving partsand wear of interior linkage mechanism, and making mainte-nance work easier. The wetted parts and the case are made of stain less steel sothat they are excellent in anti-corrosion and enviromentalresistance. By equipping a blowout disk, the effect of temperature changeon accuracy is reduced, and breakage of glass is prevented incase the Bourdon tube bursts. To indicate the working Pressure , safety mark (green mark)can be provided with an arrow mark only for 60mm and 75mmgauge as an *In case of selecting Pressure gauge, choose the Pressure rangewhich can be used in between 30 ~ 65% of full scale,so that thegauge can give its full capacity.

3 *Also should be confirmed whether the wetted parts material is suitable for the fluid or (58)(58)16G1/4B365 DIA.+ 012(33)( ) cutR1/416(58)(58)16G1/4B365 DIA.+ 012 (33)( ) cut3In case of GV50-2 3 DIA. Mounting (33)2( )135 ( )(h)(h)(19)ff35 (G)d (R) than t45 (G)322(22)13( )In case of GV42-2 3 DIA. Mounting (h)116 DIA.(h)3d (R)3100 1(Unit: mm)1820201820f3032323032dhG3/8BG1/2B1/2 NPTR3/8R1/2f123125125123125dhLG3/8BG1/2B 1/2 NPTR3/8R1 ( )(22)317(R3, NPT)d171 (G3) DIA. Mounting hole ( )In case of GV42-2 3 3L d(G3)5 (h)( )( )526171 (h)d(R3, NPT)18( )( )( ) ( )( )145 : (option)For reducing pulsating Pressure ,throttle is put on the inlet use FS10-013 Material: 316 of safety mark (option) is green and movable to any of Pressure setting locationIndication of Pressure setting the safety mark at high and low set the 2pcs.

4 Of safety mark 2(Unit: mm)SETTING METHOD OF SAFETY MARKHEAD OFFICE &OVERSEAS SALES DEPT 1-30-4, HIGASHIMAGOME OHTA-KU, TOKYO, PLANTS OR AFFILIATES: , KOREA, GERMANYOVERSEAS SALES NETWORK: AUSTRALIA, HONG KONG, INDONESIA, KOREA, MALAYSIA, PHILIPPINES, SINGAPORE, TAIWAN, THAILAND, : +81 3 3776 5328: +81 3 3776 5447: overseas_sales_dept @ : :100% Recycled (JE064A)UEDA FACTRYMARUKO FACTRYUEDA FACTORY(JQA 0794)MARUKO FACTORY (JQA 0789)The contents in the catalogue are subject to change without IN JAPAN , (N)Type No. constitutionPlease specify Type No.,each specification and range,when : For this Model,there is no applicable item for the figures X,but please specify with X when bath type Pressure gaugeG VType Document01 NilPlease specify your requirement Drawing one sheet,Instruction manual Inspection precedure,Mill sheet Test report5 Accuracy0 Standard ( )3 Wetted parts material3 Bourdon tube: 316 Socket.

5 316 Other additional specify your requirement Dial scale specified Safety mark include (Available GV53 only)8 Treatment0123 NilUse no oilUse no waterUse no oil water9 Throttle For GV5301 NilFS10-0139 Throttle For GV43$Complete with FS10-013 (Standard)2 Connection23456789G1/4BG3/8BG1/2B1/4 NPT1/2 NPTR1/4R3/8R1/2GV42 47GV44 49GV50 55GV51 56 oo o oo oo o ooo o o o o ModelMounting (type)4 Pressure range (MPa) ~ , , , , ~ 1, , 20 ~ , , , , ~ 1, , 2, , ~ 00 ~ 5, 7, 100 ~ 15, 25, 350 ~ 50, 700 ~ 1000 ~ 150, 200(When ordering,please specify Pressure range & unit.)1234567 Applicable GV42 47 only7 Window0 Standard (Organic glass)6 2 3 XXAdditional spec.(Option)Sellection 94 5 6 7 8 XXX300011 12 13 1410100 AType BType D (Mounting clamp)GV471GV4212 SizeWeightStemPanelStemPanelStemPanelSte mPanelIn throttleApprox.

6 1 kgApprox. 1 kg150 AType BType D (Mounting clamp)Type D (Mounting clamp)Type D (On line)GV491GV4412In throttleApprox. kgApprox. kgType AType BType D (Mounting clamp)GV561GV511260 AType BGV5012GV5516 Approx. kgApprox. kgApprox. kgApprox. kg