Example: bankruptcy

GMH95 / GCH95 - Goodman MFG

11/12 ContentsNomenclature ..2 Product Specifications ..3 Dimensions ..5 Airflow Data ..7 Wiring Diagrams ..9 Accessories ..11* Complete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qu / GCH95 Two-STaGe ConverTible, MulTi-Speed GaS FurnaCeS up To 96% aFueStandard Features Heavy-duty aluminized-steel dual- diameter, tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage convertible gas valve auto- matically adjust to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Self-diagnostic control board with

• Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings, according to which entrance is used: Left: One 90º street elbow; one 2½” pipe nipple; one 90º elbow; straight pipe; one ground joint union

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of GMH95 / GCH95 - Goodman MFG

1 11/12 ContentsNomenclature ..2 Product Specifications ..3 Dimensions ..5 Airflow Data ..7 Wiring Diagrams ..9 Accessories ..11* Complete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qu / GCH95 Two-STaGe ConverTible, MulTi-Speed GaS FurnaCeS up To 96% aFueStandard Features Heavy-duty aluminized-steel dual- diameter.

2 Tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage convertible gas valve auto- matically adjust to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Self-diagnostic control board with constant memory fault code Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Multi-speed blower motor Low continuous fan speed options offer quiet air circulation All models comply with California Low NOx emissions standards Cabinet Features Designed for multi-position installation: GMH95 : upflow, horizontal left or right.

3 GCH95 /GCH9: downflow, horizontal left or right Certified for direct vent (2-pipe) or non-direct vent (1-pipe) Easy to install top venting with optional side venting Convenient left or right connection for gas and electrical service Cabinet air leakage (QLeak) 2% Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section Airtight solid bottom or side-return with easy-cut tabs for effortless removal in bottom air-inlet SPecificationSProduct SPecificationSnoMenClaTure BrandRevisionsGGoodman BrandAInitial Releaseor Distinctions B1st RevisionC2nd RevisionAirflow DirectionCDownflow/HorizontalNOxDDedicat ed DownflowNNatural GasHHigh AirflowXLow NOxKDedicated UpflowMUpflow/HorizontalCabinet WidthA 14 DescriptionB 17 VTwo-Stage/Variable-speedC 21 HTwo-Stage/Multi-speedD 24

4 SSingle-Stage/Multi-speedETwo-Stage/EEM MotorMaximum CFM @ ESP3 12005 2000 AFUE4 16009595%993%+MBTU/h880%045: 45,000115: 115,000070: 70,000140: 140,000090: 90,00012AB11X10M21GH346,7,84, SPecificationSProduct SPecificationSSpeCiFiCaTionS For GMH95 GMH95 0453 BXAGMH95 0703 BXAGMH95 0704 CXAGMH95 0904 CXAGMH95 0905 CXAGMH95 1155 DXAH eating CapacityInput 46,00069,00069,00092,00092,000115,000 Natural Gas Output 44,20066,30066,30088,40088,400110,500LP Gas Output 39,80059,70059,70079,60079,60099,500 AFUE AC @ ESP334455 Temperature Rise Range ( F)35 - 6530 - 6035 - 6530 - 6030 - 6035 - 65 Circulator BlowerSize (D x W)10 x 8 10 x 8 10 x 10 10 x 10 11 x 10 11 x 10 Horsepower @ 1075 RPM Speed444444 Vent Diameter 2 2 2 2 3 3 No.

5 Of Burners233445 Filter Size (in )Permanent 290288385385480480 Disposable580580770770960960 Electrical DataMin. Circuit Ampacity Overcurrent Device (amps) 151515151515 Ship Weight (lbs)120123125144146163 Natural Gas BTU/h. For altitudes above 2,000 , reduce input rating 4% for each 1,000 above sea level. DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes).

6 The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Minimum Circuit Ampacity = ( x Circulator Blower Amps) + ID Blower amps. Wire size should be deter-mined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit break-er size. May use fuses or HACR-type circuit breakers of the same size as All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important.

7 Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local SPecificationSProduct SPecificationSSpeCiFiCaTionS For GCH95 GCH95 0453 BXAGCH95 0703 BXAGCH95 0704 CXAGCH95 0904 CXAGCH95 0905 DXAGCH93 1155 DXAH eating CapacityInput 46,00069,00069,00092,00092,000115,000 Natural Gas Output 44,20066,30066,30088,40088,400106,500LP Gas Output 39,80059,70059,70079,60079,60096,255 AFUE AC @ ESP334455 Temperature Rise Range ( F)25-5535-6525-5540 - 7035-6540 - 70 Circulator BlowerSize (D x W)10 x 8 10 x 8 10 x 10 10 x 10 11 x 10 11 x 10 Horsepower @ 1075 RPM Speed444444 Vent Diameter 2 2 2 2 2"2"No.

8 Of Burners233445 Disposable Filter Size (in )576564564752752940 Electrical DataMin. Circuit Ampacity Overcurrent Device (amps) 151515151515 Ship Weight (lbs)120123123144146160 Natural Gas BTU/h. For altitudes above 2,000 , reduce input rating 4% for each 1,000 above sea level. DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes).

9 The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Minimum Circuit Ampacity = ( x Circulator Blower Amps) + ID Blower amps. Wire size should be deter-mined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit break-er size. May use fuses or HACR-type circuit breakers of the same size as All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local SPecificationSProduct SPecificationSGMH95 diMenSionSModelABCDEGMH950453 BXA17 16 13 12 13 GMH950703 BXA17 16 13 12 13 GMH950704 CXA21 19 16 16 17 GMH950904 CXA21 19 16 16 17 GMH950905 CXA21 19 20 19 20 GMH951155 DXA24 23 20 19 20 Notes: Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required).

10 Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run, and installation (1 or 2 pipes). The optional combustion air pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. Installer must supply the following gas line fittings, according to which entrance is used: Left: One 90 street elbow; one 2 pipe nipple; one 90 elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve Installations using a bottom return: Failure to unfold duct flanges will reduce airflow area by approximately 18%.


Related search queries