GR KROHNE 04 flowmeterH 250/M9 variable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications technologyEngineering systems & solutionsSwitches, counters, displays and recordersHeat meteringPressure and temperatureH flow measurement can t be easier or more flexibleoneall-metal flowmeterfourelectrical add-on devices: ESK2-wire transmitterESK-Zelectronic totalizerESK3-PA Profibus PA transmitterKswitching contactsfourmaterials for the measuring section: stainless steel, Hastelloy,ceramic-PTFE, PTFES pecial technical featuresMeasuring sectionsH 250 RR of highly corrosion-proof stainless steel rugged all-metal design all built-in parts replaceable all pressurized welds suitable for x-ray examination float damper of aluminium oxide (Al2O3), PEEK or stainless steel,also retrofittable the measuring section can be equipped with a heating jacketH 250/C (ceramics/PTFE) suitable for most acids and alkalis very good long-time stability high-temperature design up to 250 C all wetted parts made of ceramics (Al2O3) and/or PTFEH 250/F (food) all-metal flowmeter , no blind spots surface roughness of wetted parts Ra m CIP and SIP cleanability (200 C) materials in conformity with FDA standards connections: Tri-Clamp, DIN 11851, flanges, etc.

without heating jacket DIN DN15/25 DN 50 DN 80/100 Version M9 / ESK II M9 / HT / ESK II M9 / ESK-Z M9 / HT / ESK-Z M9 / K M9 / HT / K M9 / KD M9 / HT / KD

Tags:

  Area, Variable, Flowmeter, Gr variable area flowmeter h 250

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GR Variable-area flowmeter H 250/M9 - rehe …

1 GR KROHNE 04 flowmeterH 250/M9 variable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications technologyEngineering systems & solutionsSwitches, counters, displays and recordersHeat meteringPressure and temperatureH flow measurement can t be easier or more flexibleoneall-metal flowmeterfourelectrical add-on devices: ESK2-wire transmitterESK-Zelectronic totalizerESK3-PA Profibus PA transmitterKswitching contactsfourmaterials for the measuring section: stainless steel, Hastelloy,ceramic-PTFE, PTFES pecial technical featuresMeasuring sectionsH 250 RR of highly corrosion-proof stainless steel rugged all-metal design all built-in parts replaceable all pressurized welds suitable for x-ray examination float damper of aluminium oxide (Al2O3), PEEK or stainless steel,also retrofittable the measuring section can be equipped with a heating jacketH 250/C (ceramics/PTFE) suitable for most acids and alkalis very good long-time stability high-temperature design up to 250 C all wetted parts made of ceramics (Al2O3) and/or PTFEH 250/F (food) all-metal flowmeter , no blind spots surface roughness of wetted parts Ra m CIP and SIP cleanability (200 C) materials in conformity with FDA standards connections: Tri-Clamp, DIN 11851, flanges, etc.

2 EHEDG tested / USA 3-A certifiedIndicatorM9 indicator/modular standard and EEx e direct-reading flow indicator indicator with extension piece (HT version) for high processtemperatures electrical signal output (ESK II) with HART communication in 2-wire technology (can also be retrofitted) communication interface PROFIBUS-PA, as an alternative to ESK II max. 2 limit switches (K) adjustable on the scale (can also beretrofitted) flow totalizer ESK-Z in connection with current output ESK II (can also be retrofitted, not for hazardous duty) multipole ring magnet with effective eddy-current brake optionally, seawater-proof indicator housing optionally, indicator housing of stainless steel (M9 SS)2 DescriptionThe H 250 flowmeter for measurement ofthe volumetric or mass flow rate of liquids,gases and steam is an all-metal flowmeterthat operates on the float measuring principle. The flow-dependent verticalposition of the float in the measuring tubeis transmitted by a magnetic couplingsystem to the scale in the indicator flowmeter is installed in a vertical piperun, with flow from bottom to top.

3 Owing toits rugged design, the H 250 variable -areaflowmeter is particularly suitable for difficult applications and the M9 indicator,the vertical position of the float is transmitted to the pointer/magnet system, and the flow valueindicated directly on the 250 Electromagnetic compatibility (EMC)The Variable-area flowmetertype: H 250/M9 /ESK IImeets the requirements of the 89/336/EEC directivein compliance with the following European standards:EN 61326 : 03/1997+A1 : 04/1998+A2 : 03/2001and also the requirements of NAMUR recommendation NE 21/05 (Ex) versionThe Variable-area flowmeter H 250 M9 is approved for use inhazardous Bundesanstalt:EEx ia and EEx ib 250/M9 : PTB 01 ATEX 2181 Factory Mutual Research (FM) USA:Class I, Division 1, Groups A, B, C and DClass I, Division 2, Groups A, B, C and Standards Association (CSA)Class I, Division 1, Groups A, B, C and DClass I, Division 2, Groups A, B, C and DLR 105802-7 Indicator M9 of modular construction A module rack in the M9 indicator accommodates all electrical add-on functions and the scale plate.

4 The modules of electrical options ESK II, ESK3-PA, ESK-Z,K1 or K2 and the scale plate are plugged into the module rack (plug-in technique). Module replacement or retrofitting without interrupting the processand without dismantling the pointer. If process temperatures should exceed the max. allowable level for thestandard version, the indicator can be adapted to the new operatingconditions by way of an adapter (HT version). Measuring sections made of various materials and with different linersare available for the process products. The flowmeter can be supplied with magnetic filters and/or a floatdamper, or these can be 250 ScaleFlow totalizerESK-ZModule rack M9 Indicator housingof stainless steelMeasuring section optionallywith heatingElectrical signal outputESK II or ESK3-PALimit switchunitK1/K2 orKD1/KD2 Standard housing of diecast aluminium4 Technical dataDevice typeH250 / M9 Measuring ranges (100% values)Select fluid product acc.

5 To flow tablewater (20 C)25 to 100 000 l/hair ( bar abs., 20 C) to 600 m3hTurndown ratio10:1 Accuracy class to VDI/VDE Code 3513, Sheet 2H250/RR H250/HC H250 H 250 Flanges (H250/RR/HC/C)companion dimensions toEN-1092-1DN15-100,PN16-100 ANSI B " - 4",150 - 600 lbsJIS B 2238 LR 15-100,10K-20 KClamp connections (H 250/RR/F)companion dimensions toDlN 32676DN15 - 100,10-16 barISO 2852size 25-139,710-16 barScrew connections (H 250/RR/HC/F) companion dimensions toDIN 11851DN15 - 100,25 - 40 barSMS11461"- 4", 6 barInside thread, welded (RR, HC)companion dimensions toISO 228 G3/4" -, G1" PN 50 ANSI " NPTI nside thread, screwed (RR, HC)companion dimensions toISO 228G1/2" - 1",(with insert and union nut)PN 40 - 50 ANSI B " - 1" NPTS terile screw connection (H 250/F)companion dimensions toDIN 11864 - 1DN 15 - 50 : PN 40DN 80 - 100 : PN 16 Sterile flange (H 250/F)companion dimensions toDIN 11864 - 2 DN 15 - 50 : PN 40DN 80 - 100.

6 PN 16 Connection for heating system (H 250/RR/HC)flange connectionEN 1092-1DN 15; PN 40 ANSI B 1/2"; 150 lbs / RFpipe connection for ErmetoE12, PN 40 Information on higher pressure ratings and other types of connection supplied on requestMeasuring tubeH 250/RRmetal tube with tapered measuring sectionH250/HC (Hastelloy C4) metal tube with tapered measuring sectionH 250/C (ceramics/PTFE)measuring tube with standard orifice plateFloat shapesH250/RR,liquidsCIV, DIV (damping possible)H250/HC (Hastelloy C4)gasesTIV, DIV, DIVT (damping possible)H250/C (ceramics, PFTE):liquids, gasestapered, type EScale marksflow unitsOverall heightwith flange connection (excl. gaskets)250 mmwith special connections300 mm (H 250/RR)Operating pressure PSDirective 97/23/EC of the Council dated 29 April 1999 concerning transportable pressure equipment(pressure specified)(pressure equipment directive) applies. The max. allowable operating pressure PS is calculated for themax.

7 Allowable operating temperature TS. Both limits values (PS and TS) are specified on the is normally equivalent to the nominal pressure of the pressure PT (pressure tested)The test pressure is calculated in accordance with pressure equipment directive (97/23/EC) and/or AD 2000-HP30, in compliance with the max. allowable operating pressure and the max. operating temperatureType of protection of indicator M9 to EN 60529 / IEC 60529IP 67, NEMA 4XH 250 Responsibility for these measuring devices as to suitability, designated use and corrosion resistance of the materials used in relation to the process product rests solely with the 250without heating jacketDINDN15/25DN 50DN 80/100 VersionM9 / ESK IIM9 / HT / ESK IIM9 / ESK-ZM9 / HT / ESK-ZM9 / KM9 / HT / KM9 / KDM9 / HT / KDM9 / ESK IIM9 / HT / ESK IIM9 / ESK-ZM9 / HT / ESK-ZM9 / KM9 / HT / KM9 / KDM9 / HT / KDM9 / ESK IIM9 / HT / ESK IIM9 / ESK-ZM9 / HT / ESK-ZM9 / KM9 / HT / KM9 / KDM9 / HT / KDwith heating jacketDIN DN15 DN 25DN 50DN 805 VersionH250 / RRH250 / HCH250 / CH250 / CH250 / CH 250 Die Verantwortung hinsichtlich Eignung und bestimmungsgem sser Verwendung unserer Ger te liegt allein beim 250 Max.

8 Process temperature TS H250/ .. / M9 (excl. built-in electrical equipment) (TS = temperature specified)Materialstainless steelHastelloy C4 FloatLinerPTFEPTFE ceramicsPTFE ceramicsTFMMax. process temperature TS [ C]30030070150250at ambient temperature Ta [ C] 120 120 70 70 120 Min. process temperature TS-80 C, others on requestMin. ambient temperature Ta-40 CMax. process temperatures TS in non-hazardous area for H 250 / M9 with built-in electrical equipmentANSI1/2", 1"2"3", 4"ANSI 1/2" 1"2", 3"Max. allowable process temperatures in CTa < 40 CTp C200300200300200300200300200300180300200 300200300200300150270200300190300Ta < 60 CTp C (1)Tp C (2)1801503002358080130130200150300235130 1302952351651253001707575100100200125300 1701201201951701501052501457070858520010 5300145110105160145(1) heat-resistant cable required, with a continuous operating temperature of 100 C(2) heat-resistant cable not requiredCode designations:ESK II- signal output 4.

9 20 mAESK-Z- flow totalizerHT- high-temperature versionK- switching contact / 2-wireKD- switching contact / 3-wire6H 250 Die Verantwortung hinsichtlich Eignung und bestimmungsgem sser Verwendung unserer Ger te liegt allein beim 250 Variable-area flowmeters of type H 250/M9 -EEx with built-in electrical equipment are dependent on the temperature class and tables for determining the allowable temperature class take account of the following parameters:-built-in equipment-allowable max. power loss Pi (for K1 and K2)-ambient temperature Tamb-process temperature Tp TS (max. allowable operating temperatures, non-"Ex" applications)-meter size DN-standard or high-temperature version (HT)-standard or heating jacket version-heat resistance of the power cableWhere several built-in intrinsically safe devices are used, the user should take the data of the worst case device as a ESK II-EEx (-AEx)Max. allowable process temperature Tp[ C]Temperature class to EN 50014T6T5T4T3T2, T1 Tamb[ C] 40 60 40 60 60 40 60 40 60withoutwithHigh-Heat-resistant heating heating temperaturecable required for jacketjacketversionTp[ C] and higherDN 15DN 15----15085100135200183200183DN 25x----23685100135200200300300DN 50DN 25----12785100135200165200165x----171851 00135200200300300DN 80DN 50----10985100135200150200150DN 100DN 80x----14585100135200200300252 Temperature classes for H 250 / M9 EEx to PTB 01 ATEX 2181 Max.

10 Allowable process (Tp) and ambient (Tamb) temperatures H 250/../M9/ ESK 3-PA-EExMax. allowable process temperature Tp[ C]Temperature class to EN 50014T6T5T4T3T2, T1 Tamb[ C] 40 60 40 60 60 40 60 40 60withoutwithHigh-Heat-resistantheating heating temperaturecable required forjacketjacketversionTp[ C] and higherDN 15DN 15----1508376135 200183200183DN 25x----23685100135200200300300DN 50DN 25----1277774135 200165200165x----1718591135 200200300300DN 80DN 50----1097172135 200150200150DN 100DN 80x----1458585135 2002003002527H 250 Die Verantwortung hinsichtlich Eignung und bestimmungsgem sser Verwendung unserer Ger te liegt allein beim 250 Max. allowable process (Tp) and ambient (Tamb) temperatures H250/../M9 (-AEx) with SC3,5-NO-Y .. /Pi 64 mWMax. allowable process temperature Tp[ C]Temperature class to EN 50014T6T5T4T3T2, T1 Tamb[ C] 40 60 40 60 60 40 60 40 60withoutwithHigh-Heat-resistantheating heating temperaturecable required forjacketjacketversionTp[ C] and higherDN 15DN 15----15085100135 200200200200DN 25x----23685100135200200300300DN 50DN 25----12785100135 200200200200x----17185100135 200200300300DN 80DN 50----10985100135 200200200200DN 100DN 80x----14585100135 200200300300/ K.