Example: barber

Grace GC Capillary Column Families - MZ-AT

Chromatographygc columns | capillaryGrace GC Capillary Column Familiestech tipTemperature limitsOur GC Capillary columns are temperature rated. In some cases, we list two maximum operating temperatures, the lower one is for isothermal condition and the higher one for temperature-programmed condition. Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases5382 Grace offers two lines of Capillary columns to suit every application and budget; Alltech Heliflex and Alltech Econo-Cap . Heliflex columns are Grace s premium line of individually tested Capillary columns . Econo-Cap columns are batch tested to dramatically reduce the price without sacrificing quality.

www.discoverysciences.com 213 gas chromatography gc columns | capillary Grace® GC Capillary Column Families tech tip Temperature limits Our GC capillary columns are temperature rated.

Tags:

  Capillary, Families, Columns, Gc capillary column families, Capillary column

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Grace GC Capillary Column Families - MZ-AT

1 Chromatographygc columns | capillaryGrace GC Capillary Column Familiestech tipTemperature limitsOur GC Capillary columns are temperature rated. In some cases, we list two maximum operating temperatures, the lower one is for isothermal condition and the higher one for temperature-programmed condition. Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases5382 Grace offers two lines of Capillary columns to suit every application and budget; Alltech Heliflex and Alltech Econo-Cap . Heliflex columns are Grace s premium line of individually tested Capillary columns . Econo-Cap columns are batch tested to dramatically reduce the price without sacrificing quality.

2 Both the Heliflex and Econo-Cap lines are manufactured under identical conditions using the same high-quality polyimide coated fused silica and immobilized stationary phases. In addition each are mounted on a rugged cage. Regardless of the Capillary line you choose, every Grace manufactured Capillary Column has a guarantee of Column Heliflex Capillary columns High-performance individually tested columns 7" rugged cage Most complete selection of phases Custom columns available to suit your specific applicationHeliflex Capillary columns are manufactured from the highest quality polyimide coated synthetic fused silica. They are mounted on a rugged wear-resistant cage.

3 Each Heliflex Column is individually tested to guarantee Column performance and comes with a test chromatogram, instruction manual, Capillary end caps, and a free ceramic Column : Column nuts and ferrules are not included. If the Column you need is not available in our standard offering, request a custom Heliflex Column made to your individual Econo-Cap Capillary columns Best value in Capillary columns anywhere Batch tested to dramatically reduce price Ideal for aggressive applications Available in the most popular phasesWe ve taken our most popular Capillary columns and perfected the manufacturing procedure to the point that reproducibility is assured. This allows us to test these columns in batches instead of individually, while still offering a guarantee.

4 Batch testing significantly reduces cost in production without sacrificing Econo-Cap Capillary Column comes with a copy of the batch test results, an instruction manual, and Capillary end caps. If you are not completely satisfied with the quality of your Econo-Cap Capillary Column it will be replaced at no : Column nuts and ferrules are not Alltech Heliflex PhasesPhasePageAT -1ms216AT -1ht216AT -1217AT -5ms218AT -5218AT -20219AT -35ms220AT -35220AT -50221AT -624226AT -1301221AT -1701222AT -210222AT -225226AT -WAXms223AT -WAX223AT -AquaWax224AT -AquaWax-DA224AT -1000225AT -FAME225AT -CAM225AT -Amino Acid228 Drug 1, Drug 2, and Drug 3228 USP Method 467 Kits229AT -Pesticide230AT -Petro231AT -2887231AT -3710231AT -Sulfur231AT -Amine231AT -Silar-90227AT -Silar-100227 Available Alltech Econo-Cap PhasesPhasePageEC -1217EC -5219EC -20219EC -WAX224EC -1000225premiumvalue42000-07-213-signatu re 07 2008 catalog Grace proof 6 (rjh)

5 November 5 , 2007the henderson company 400 west erie, chicago illinois 60610 (312) 951-8973 f (312) chromatographygc columns | capillaryCapillary Column Phase Cross ReferenceUse the chart below to cross reference manufacturers stationary phases as well as USP method designations to Alltech equivalent columns . Slight variations in selectivity may result between different manufacturers Standard Phase Cross ReferenceAlltech Specialty columns Cross ReferenceSpecialty Phases Cross ReferenceEPA Method 608AT -Pesticide007-608, DB-608, HP-608, SPB -608 EPA Method , 007-502, , DB-VRX, HP-624,HP-VOC, , MXT-624, MXT-Volatiles, OV -624, Rtx , Rtx -624,Rtx -Volatiles, VOCOL Sulfur AnalysisAT -SulfurSPB -1 SulfurFAME AnalysisAT -FAMEFAMEWAX , OmegaWAX Standard Phase Cross ReferenceComposition Alltech BrandUSP.

6 Designation Similiar Phases100% Dimethylpolysiloxane AT -1msG1, G2, G38DB-1ms, HP-1ms, Rtx -1ms, CP-Sil 5CB low-bleed/ms100% Dimethylpolysiloxane AT -1ht, AT -1,EC -1G1, G2, G38007-1, CP-Sil 5CB, DB-1, DB-1ht, HP-1, HP-101,OV -1, RSL-150, RSL-160, Rtx -1, SE-30 , SPB -1, SPB -Sulfur, ULTRA-1, SP-2100, BP-1, DC-200, PE-1, ZB-15% Phenyl equivalentPolysilphenylene-SiloxaneAT -5msDB-5ms, Rtx -5 Sil ms, BPX -5, 007-5ms, HP-5ms(5% Phenyl)- 95% methylpolysiloxaneAT -5, EC -5G27, G36007-2, CP-Sil 8CB, DB-5, , DB-5ht, HP-5,HP-5ms, OV -5, PTE-5, PTE-5 QTM, PAS-5, RSL-200, Rtx -5, Rtx -5ms, SAC-5, SE -54, SPB -5, ULTRA-2, XTI-5, SE -52, BP-5, PE-2, ZB-5(20% Phenyl)- 80% methylpolysiloxane AT -20, EC -20G28, G32007-7, Rtx -20, SPB -20, VOCOL , PE-7(35 Phenyl)-65% MethylpolysiloxaneAT -35msAT -35G42DB-35ms, Rtx -35, SPB -35, SUP -H ERB , MDN-35, BPX -35007-11, DB-35, DB-35ms, HP-35, RSL-300, Rtx -35, SPB -35, SPB -608, OV -11, PE-35, SUP -H ERB (50 Phenyl)-50% methylpolysiloxaneAT -50G3DB-17ms, H5-50+, Rtx -50, SP-2250, SPB -50, SPB -17, BPX -50DB-17ht, Rtx -65TG, BPX -50, CP-TAB-CB, 007-17, DB-17, DB-17ht, HP-17, HP-50+, Rtx -50 SP-50, SP-2250, SPB -50, CP-Sil 24CB, PE-17, ZB-50(6% Cyanopropylphenyl)

7 -94% methylpolysiloxane AT -624AT -1301 G43007-1301, DB-624, DB-1301, HP-1301, HP-624,Rtx -1301, Rtx -624, SPB -1301, SPB -624, 007-624, ZB-624(14% Cyanopropylphenyl)-86% methylpolysiloxane AT -1701 007-1701, CP-Sil 19CB, DB-1701, HP-1701, OV -1701, PAS-1701, Rtx -1701, SPB -1701, BP-10, ZB-1701 Trifluoropropylmethyl polysiloxaneAT -210G6DB-210, RSL-400, Rtx -200, OV -202, OV -210, OV -215, QF-1, SP-2401(50% Cyanopropylphenyl)-50% methylpolysiloxaneAT -225G7007-225, CP-Sil 43CB, DB-225, HP-225, OV -225, RSL-500, Rtx -225, BP-225, PE-225 Poly(80% biscyanopropyl)-20% cyanoproylphenyl siloxaneAT -SILAR-90G8DB-23, CP-Sil 84, Rtx -2330, SP-2330 Poly(biscyanopropylsiloxane)

8 AT -SILAR-100G5CP-Sil 88, Rtx -2330, SP-2340 PolyethyleneglycolAT -WAXmsAT -WAXAT -AquaWaxEC -WAXG14, G15G16, G20,G39 DB-WAX, Rtx -WAX, Supelcowax -10007-CW, Carbowax 20M, CP-Wax 52CB, DB-WAXetr,DB-WAX, Rtx -WAX, HP-20M, HP-Wax, Innowax ,Omegawax , Stabilwax , Supelcowax -10, Superox II, BP-20, ZB-WAXP olyethyleneglycolAcid Modified AT -1000, EC -1000, AT -AquaWax-DA G25, G35007-FFAP, CP-Wax 58CB, DB -FFAP, HP -FFAP, Nukol , OV -351, SP-1000, Stabilwax -DA, Superox -FA, BP-21 PolyethyleneglycolBase ModifiedAT -CAMS tabilwax -DB, CAM, Carbowax Amine, CP Wax 51 PONA AnalysisAT , CP-Sil PONA CB, DB-Petro100, Petrocol DH, PONA, Ttx-1 PONA, HP-PONAASTM Method 2887AT , DB-2887, Petrocol 2887, Petrocol EX2887, Rtx -2887, Sim-Dist-CBASTM Method 3710AT -3710 Petrocol 371042000-07-214-signature 07 2008 catalog Grace proof 6 (rjh) november 5 , 2007the henderson company 400 west erie, chicago illinois 60610 (312) 951-8973 f (312) chromatographygc columns | Capillary A wide selection of stationary phases Lengths from 1 to 105 meters Wide selection of tubing Every Column individually testedCustom Capillary Column Instructions1.

9 Stationary Phase: Choose a Phase in Table 1: Custom Phase. 2. Length & Internal Diameter: Choose any length (1 105 meters) and internal diameter ( ) in Table 2: Custom Dimensions. 3. Film Thickness: Choose a film thickness; m See Coiling and Guard Information for additional Call Customer Service and they will confirm your order and provide exact Heliflex Custom Capillary Phase and Phase and Phase and Phase and Phase and Phase and Film9750106 Phase and Phase and Phase and Phase and Phase and Phase and Film97501516 Phase and Phase and Phase and Phase and Phase and Phase and Film97503031 Phase and Phase and Phase and Phase and Phase and Film97506061 Phase and Phase and Phase and Phase and Film975105 Custom CapillaryAll other Dimensions not specified970123 Custom CoilingDescriptionPart Capillary on 4" Cage970124

10 Custom Capillary Column with Integral GuardCustom Capillary Column with Integral GuardDescriptionPart No. Custom with Integral 5m GuardC-5400 Custom with Integral 5m GuardC-5500 Custom with Integral 5m GuardC-5600 Phases Available for Custom Capillary ColumnsCustom Capillary CoilingTable 2: Custom DimensionsTable 1: Custom PhasesAlltech Custom Capillary columns Aquawax Aquawax-DA AT -1 AT -5 AT -20 AT -35 AT -1000 AT -1301 AT -1701 AT -WAX AT -Amine Apiezon phases Apolane -87 Butanediol succinate (Craig s polyester) Carbowax phases DC-550 Dexsil 300 Dexsil 400 Dexsil 410 Di (2ethylhexyl phthalate Diisodecyl phthalate FFAP Hi-EFF -1AP Hi-EFF -1BP Hi-EFF -2AP Hi-EFF -2BP Hi-EFF -3AP Hi-EFF -3BP Hi-EFF -4BP Hi-EFF -8BP Igepal CO-880 OV -1 OV -11 OV -17 OV -1701 OV -61 OV -101 OV -105 OV -210 OV -351 Polyvinylpyrrolidone Reoplex 400 SE-30 Squalane Superox -FA XE-60technical assistanceContact Tech Support: Phone.)


Related search queries