Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. A8. > Monitored electrostatic earthing of tank containers, barrels, road tankers, rail cars, and IBCs during loading A8. > Continuous Monitoring of correct Grounding > Robust design > Weather-protected plastic A8. enclosure (IP66) or stainless steal enclosure (IP66). > Potential-free contact for signalling to the process control A8. system and external control devices > Insulated point of suspension > For use up to SIL 2 (IEC 61508) A8. A8. Series 8146/5075 and 8150/5-V75 A8. 14834E00. A8. The ground Monitoring Device ensures that tank containers, drums, road tankers, rail cars and IBCs are correctly electrostatically grounded during the loading of flammable liquids. The Device provides a conductive connection to the ground and monitors A8. in parallel the quality of the electrostatic Grounding . This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy A8.

Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75 A8/2 Grounding Systems and Grounding Monitoring Devices 2016-09-14·EK00

Tags:

  Ek00

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Grounding Systems / Grounding Monitoring Device …

1 Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. A8. > Monitored electrostatic earthing of tank containers, barrels, road tankers, rail cars, and IBCs during loading A8. > Continuous Monitoring of correct Grounding > Robust design > Weather-protected plastic A8. enclosure (IP66) or stainless steal enclosure (IP66). > Potential-free contact for signalling to the process control A8. system and external control devices > Insulated point of suspension > For use up to SIL 2 (IEC 61508) A8. A8. Series 8146/5075 and 8150/5-V75 A8. 14834E00. A8. The ground Monitoring Device ensures that tank containers, drums, road tankers, rail cars and IBCs are correctly electrostatically grounded during the loading of flammable liquids. The Device provides a conductive connection to the ground and monitors A8. in parallel the quality of the electrostatic Grounding . This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy A8.

2 Discharge. ATEX / IECEx Zone 0 1 2 20 21 22 A8. Ex i interface x x x x x x For use in x x x x A8. A8. A8. WebCode 8146H. A8. 2016-09-14 ek00 III en Grounding Systems and Grounding Monitoring Devices A8/1. Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. Selection Table Version Description Order number Art. no. Grounding Monitoring Device 8146/5075 8146/5075 136216. without cable. The Device ensures that drums and tank containers are correctly electrostatically grounded and continuously monitors the connection. 12753E00. Ground Monitoring Device 8146/5075. Grounding Monitoring Device 8150/5-V75 8150/5-V75 256498. without cable. The Device ensures that drums and tank containers are correctly electrostatically grounded and continuously monitors the connection. For use up to SIL 2. 14728E00. Ground Monitoring device8150/5-V75. 10 m oil and petrol resistant cable with robust ergonomic 247673. Grounding clamp of stainless steel, and fast-action plug 12056E00.

3 Grounding clamp with cable 5 m oil and petrol resistant spiral cable with robust 247672. ergonomic Grounding clamp of stainless steel, and fast-action plug 10 m oil and petrol resistant spiral cable with robust 247674. ergonomic Grounding clamp of stainless steel, and fast-action plug 12055E00. Grounding clamp with spiral cable Automatic winder with 9 m of oil and petrol resistant cable 247660. with robust ergonomic Grounding clamp of stainless steel, and fast-action plug, Plastic enclosure 17637E00. Grounding clamp with automatic cable winder Automatic winder with 20 m of oil and petrol resistant cable 247671. with robust ergonomic Grounding clamp of stainless steel, and fast-action plug, Aluminium enclosure, protected cable duct with stopper 17636E00. Grounding clamp with automatic cable winder Robust ergonomic Grounding clamp with 150 mm 247675. of cable and fast-action plug 17638E00. Grounding clamp Note *) Special cable length possible on request.

4 Price and date of delivery differ from the standard. A8/2 Grounding Systems and Grounding Monitoring Devices 2016-09-14 ek00 III en Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. A8. Explosion Protection Design 8146/5075 8150/5-V75. Global (IECEx). Gas and dust IECEx PTB IECEx PTB Ex d e [ia Ga] IIC T4 Gb Ex db eb [ia Ga] IIC T4 Gb A8. Ex tb IIIC T80 C Db Ex tb IIIC T80 C Db Europe (ATEX). Gas and dust PTB 01 ATEX 1024 PTB 09 ATEX 1109. E II 2 (1) G Ex d e [ia Ga] IIC T4 Gb E II 2 (1) G Ex db eb [ia Ga] IIC T4 Gb E II 2 D Ex tb IIIC T80 C Db E II 2 D Ex tb IIIC T80 C Db A8. Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), IECEx, ATEX, Brazil (INMETRO), Kazakhstan (TR), Russia (TR), Belarus (TR) Kazakhstan (TR), Russia (TR), Belarus (TR). Ship approval DNV GL DNV GL. Further parameters A8. Installation in Zones 1, 2, 21, 22 in Zones 1, 2, 21, 22. Technical Data Electrical data Power supply A8.

5 Rated voltage 110 to 230 V AC 110 to 230 V AC. Nominal voltage range 96 to 253 V AC 96 to 253 V AC. Frequency range 48 to 62 Hz 48 to 62 Hz Nominal current 33 mA 33 mA. Power consumption 3 VA 3 VA A8. Cable diameter range 6 to 13 mm 6 to 13 mm of cable gland (M20). Output Signalling contact potential-free change-over contact (Ex e) potential-free change-over contact (Ex e). Maximum load AC 250 V / 4 A 250 V / 4 A A8. Maximum load DC 250 V / 2 A 250 V / 2 A. 40 V / 3 A 40 V / 3 A. Max. switching 50 W / 1000 VA 50 W / 1000 VA. capacity Minimum load LED display 12 V / 100 mA 12 V / 100 mA A8. Operating mode: State of Grounding Reaction of the Grounding Monitoring Device Clamp is not connected, Grounding incorrect Device not in use red indicator lamp ON A8. green indicator lamp OFF. Switching contact OPEN. 10938E00. A8. Clamp connected to tank Grounding ok container or drum. red indicator lamp OFF. green indicator lamp ON. Switching contact CLOSED A8.

6 08030E00. Functional safety (IEC 61508) A8. Test report Exida STAHL 11/07-089 R022. Max. SIL 2. Safe state relay released / no release Safe Failure Fraction SFF. PFDAVG at T[Proof]. 73%. T[Proof] 1 year 2 years 5 years A8. PFDAVG 4,14 x 10-4 x 10-4 x 10-3. A8. 2016-09-14 ek00 III en Grounding Systems and Grounding Monitoring Devices A8/3. Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. Technical Data Ambient conditions Ambient temperature -20 to +55 C. Storage temperature -40 to +80 C. Mechanical data Design 8146/5075 8150/5-V75. Degree of protection IP66 IP66. Material Enclosure Glass-fibre-reinforced polyester resin, Stainless steel (AISI 316L). flame-resistant Grounding clamp Stainless steel (tong limbs) and Stainless steel (tong limbs) and (clamping jaw) (clamping jaw). Weight kg kg Mounting / Installation Connection grey & green-yellow blue Single-wire connection - rigid .. 6 mm2 .. 4 mm2. - flexible .. 4 mm2.

7 Mm2. - flex. with core end sleeves with plastic sleeve .. mm2 .. mm2. - flexible with core end sleeves without plastic .. 4 mm2 .. mm2. sleeve Cable gland Auxiliary power Threads M20 M25. Clamping range 4 to 13 7 to 17. Auxiliary contacts Threads M25 M25. Clamping range 7 to 17 mm 7 to 17 mm Ex i Monitoring Threads M20 M20. Clamping range 4 to 13 mm 4 to 13 mm Grounding clamp Threads M20 M20. Clamping range 4 to 13 mm 4 to 13 mm Threads M25 M25. Clamping range 7 to 17 7 to 17. Tightening torque Threads M20 M25. Tightening torque (at 20 C) Nm Nm Explosion Protection Design Grounding clamp with cable Europe (ATEX). Gas and dust DMT 00 ATEX E 068 X. E II 2 G Ex ia IIC T6 Gb E II 2 D Ex ia IIIC T135 C Db Certifications and certificates Certificates ATEX. Europe (ATEX). Gas and dust DMT 00 ATEX E 068 X. E II 2 G Ex ia IIC T6 Gb E II 2 D Ex ia IIIC T135 C Db Further parameters Installation in Zones 1, 2, 21, 22. Technical Data Design Grounding clamp Cable Ambient conditions Ambient temperature -20 to +70 C -20 to +90 C.

8 Storage temperature -40 to +90 C -40 to +90 C. A8/4 Grounding Systems and Grounding Monitoring Devices 2016-09-14 ek00 III en Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. A8. Explosion Protection Design Automatic cable winder Europe (ATEX). Gas and dust DMT 00 ATEX E 068 X. E II 2 G Ex ia IIC T6 Gb A8. E II 2 D Ex ia IIIC T135 C Db Maximum surface temperature: 70 C. (dependent on ambient temperature, not on Device ). Certifications and certificates Certificates ATEX A8. Further parameters Installation in Zones 1, 2, 21, 22. Technical Data Design Automatic cable winder with 20 m of cable (art. no. 247671). Automatic cable winder with 9 m of cable (art. no. 247660). A8. Ambient conditions Ambient temperature -20 to +70 C -20 to +70 C. Mechanical data Degree of protection IP43 IP42 A8. Material Enclosure Aluminium ribbed and reinforced, protected Plastic, cable duct with rollers cable duct with stopper Return mechanism automatic, stopping Device can be switched.

9 Grounding cable on and off 20 m oil and petrol resistant Grounding cable, 9 m oil and petrol resistant Grounding cable, A8. 3 x mm 3 x mm Temperature range: -20 .. +90 C Temperature range: -20 .. +90 C. Connected 4-pole plug receptacle, IP67 Connected 4-pole plug receptacle, IP67. Weight approx. 14 kg with 20 m Grounding cable approx kg with 9 m Grounding cable Fire resistance (UL 94) HB A8. Mounting / Installation Mounting Wall mounting with mounting plate Wall mounting with mounting plate Connection m, connection cable 3 x mm2 m, connection cable 3 x mm2. A8. A8. A8. A8. A8. A8. A8. 2016-09-14 ek00 III en Grounding Systems and Grounding Monitoring Devices A8/5. Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 114 [4,49]. 91 [3,58]. 213 [8,39]. 190 [7,48]. 9,5 [0,37]. 242 [9,53]. 16 [0,63]. 136,5 [5,37]. 230 [9,06] 7 [ 0,28] 25 [0,98]. 28 [1,10 ].

10 152 [5,98]. 360 [14,17]. 9 [0,35]. 340 [13,39]. 396 [15,60]. 288,50 [11,36]. 399 [15,71]. 377 [14,84]. 340,50 [13,41]. ~ 436 [~ 17,17]. ~ 414 [~ 16,30]. 7 [0,28]. 148 [5,83] 156,5 [6,16]. 170 [6,69] 176,5 [6,95]. 08029E00 14867E00. Grounding Monitoring Device 8146/5075 Grounding Monitoring Device 8150/5-V75. 270,50 [10,65]. 158 [6,22] 112,50. [4,43]. Z. 212 [8,35]. 71 [2,80]. Z 110 [4,33]. 80 [3,15]. [3,54]. 90. 41,50. [1,63]. 7 7. [ 0,28] [ 0,28]. 17658E00. Cable drum with automatic cable winder (Art. no. 247660). A8/6 Grounding Systems and Grounding Monitoring Devices 2016-09-14 ek00 III en Grounding Systems / Grounding Monitoring Device Series 8146/5075 and 8150/5-V75. A8. Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 185. [7,28]. 520 [20,47]. 110 [4,33] A8. 164 [6,46]. 0 . 16. 78 [3,07]. 30 . 360 [14,17]. [2,95]. 182 [7,17]. 75. [5,91]. Y. 150. A8.. 60. [ 0,39]. 10. 40 [1,57] 160 . A8. 10,50. [ 0,41]. 54,50. [2,15].