Example: confidence

H07RN-F - Farnell

H07RN-F Lead freeYesMechanical resistance to impactsVery goodCable flexibilityFlexibleChemical resistanceAccidentalWater proofGoodOperating temperature, range-25 .. 55 CGenerated 4/18/06 - 1 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Industrial flexible cable, insulation and outer sheath in elastomer Standards International HD ; HD 516; IEC 60245-4 type 66 National NF C 32-102-4 DescriptionApplicationH07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for building sites.

Core identification in accordance with HD 308 S2 (October 2001)Identification of cores in cables and flexible cords. Number of cores HD 308 S2 since january 2004 G (earth core) X (without earth core) 1 Black (preferential) Black (preferential) 2 Blue + Brown Blue + Brown 3* Green - Yellow + Blue + Brown Brown + Black + Grey 3** Blue + Brown + Black

Tags:

  Core

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of H07RN-F - Farnell

1 H07RN-F Lead freeYesMechanical resistance to impactsVery goodCable flexibilityFlexibleChemical resistanceAccidentalWater proofGoodOperating temperature, range-25 .. 55 CGenerated 4/18/06 - 1 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Industrial flexible cable, insulation and outer sheath in elastomer Standards International HD ; HD 516; IEC 60245-4 type 66 National NF C 32-102-4 DescriptionApplicationH07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for building sites.

2 The cable may be rated 0,6/1 kV where the installation has built-in protection and for motors in lifting appliances - machine tools - cable can be used in refrigerating installations. InstallationThis cable can be installed in open air or be buried but with extra mechanical laid up Assembled <HAR> N (x ou G) SN = number of cores G = with Green-Yellow x = without Green-Yellow S = section in mm NotaMax continuous operating conductor temperature in normal use :+60 C ( in every case of mobile installation)+85 C ( fixed protected installation )+200 C ( in short circuit ) Permissible current rating is measured for an ambient temperature of 30 C and a maximum operating and conductor temperature of 85 C . For other temperature please refer to correction factors.

3 H07RN-F Lead freeYesMechanical resistance to impactsVery goodCable flexibilityFlexibleChemical resistanceAccidentalWater proofGoodOperating temperature, range-25 .. 55 CGenerated 4/18/06 - 2 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. ContactNexans - Building activity 4-10 rue Mozart 92587 Clichy Generated 4/18/06 - 3 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

4 CharacteristicsConstruction characteristics Outer sheathSpecial cross-linked elastomer Sheath colourBlack InsulationSpecial cross-linked elastomer Lead freeYesMechanical characteristics Mechanical resistance to impactsVery good Cable flexibilityFlexibleUsage characteristics Chemical resistanceAccidental Water proofGood Short-circuit maximum core temperature200 C Operating temperature, range-25 .. 55 C Maximum core temperature still60 C New cores identificationCore identification in accordance with HD 308 S2 (October 2001)Identification of cores in cables and flexible of coresHD 308 S2 since january 2004G (earth core )X (without earth core )1 Black (preferential)Black (preferential)2 Blue + BrownBlue + Brown3*Green - Yellow + Blue + Brown Brown + Black + Grey3** Blue + Brown + Black4 Green - Yellow + Brown + Black + GreyBlue + Brown + Black + Grey5 Green - Yellow + Blue + Brown + Black + GreyBlue + Brown + Black + Grey + Black> 5 White printed numbers + 1 Green - YellowWhite printed numbers* For the cables without Green/Yellow with a cross-section >4mm ** For the cables without Green/Yellow with a cross-section of 1,5mm & 2,5mm Single core Cross section mm Perm.

5 Current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km Generated 4/18/06 - 4 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km Two cores Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km Three cores Cross section mm Perm.

6 Current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km H07RN-F Generated 4/18/06 - 5 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Four cores Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km Five cores Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max.

7 Linear resistance, phase conductor Ohm/km Twelve cores Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km H07RN-F Generated 4/18/06 - 6 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Eighteen cores Cross section mm Perm. current rating open air A Voltage drop, single phase Max. outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km thirty six cores Cross section mm Perm. current rating open air A Max.

8 Outer diam. mm Approx. weight kg/km Max. linear resistance, phase conductor Ohm/km