halo . DESCRIPTION. Catalog # Type The halo Surface LED Downlight (SLD) incorporates WaveStream . technology to create an ultra-low profile surface mounting luminaire with the performance and look of a traditional downlight. SLD6-1200 Project UNV series is designed for installation in many 4 x 2-1/8 deep square junction boxes. Accessory mounting kit allows retrofit in 5 and 6 IC Date Comments and Non-IC recessed housings.* Suitable for residential or commercial installations. Ideal for closets, storage areas, attics and basements. Compliant with NFPA 70, NEC Section (A)(3) and (C)(5). Prepared by SPECIFICATION FEATURES. CONSTRUCTION junction box, not the SLD. LED CHROMATICITY. Die cast aluminum trim ring, and Installer must ensure A tight chromaticity specification die formed aluminum frame compatibility of fit, wiring and ensures LED color uniformity, proper mounting in the sustainable Color Rendering OPTICS. electrical junction box. Index (CRI) and Correlated WaveStream technology This includes all applicable Color Temperature (CCT) over provides uniform luminance national and local electrical and the useful life of the LED.

Halo SLD 1200 UNV spec sheet - TD518030EN Halo SLD 1200 UNV spec sheet - TD518030EN

Tags:

  Sheet, 2010, Spec, Halo, Halo sld 1200 unv spec sheet td518030en, Td518030en, Halo sld 1200 unv spec sheet td518030en halo sld 1200 unv spec sheet td518030en

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Halo SLD 1200 UNV spec sheet - TD518030EN - …

1 halo . DESCRIPTION. Catalog # Type The halo Surface LED Downlight (SLD) incorporates WaveStream . technology to create an ultra-low profile surface mounting luminaire with the performance and look of a traditional downlight. SLD6-1200 Project UNV series is designed for installation in many 4 x 2-1/8 deep square junction boxes. Accessory mounting kit allows retrofit in 5 and 6 IC Date Comments and Non-IC recessed housings.* Suitable for residential or commercial installations. Ideal for closets, storage areas, attics and basements. Compliant with NFPA 70, NEC Section (A)(3) and (C)(5). Prepared by SPECIFICATION FEATURES. CONSTRUCTION junction box, not the SLD. LED CHROMATICITY. Die cast aluminum trim ring, and Installer must ensure A tight chromaticity specification die formed aluminum frame compatibility of fit, wiring and ensures LED color uniformity, proper mounting in the sustainable Color Rendering OPTICS. electrical junction box. Index (CRI) and Correlated WaveStream technology This includes all applicable Color Temperature (CCT) over provides uniform luminance national and local electrical and the useful life of the LED.

2 From a low profile flat lens building codes. LED chromaticity of 3 SDCM. AccuAim optics provide Proprietary Slot-N-Lock quick exceeds ENERGY STAR directional control for the installation system for junction color standards per ANSI. cone-of-light beam distribution of a traditional downlight. box installation 90 CRI model features high SLD6 1200 UNV. T-bracket with Slot-N-Lock color performance with R9. Precision molded lens features mounting tabs included greater than 50. Series high transmission polymer with UV stabilized protecting film OPTIONAL - RECESSED HOUSING. Every halo LED is quality tested, Universal Voltage measured, and serialized in a MOUNTING. DESIGNER TRIMS permanent record to register SLD6128xxWHUNVJB. Accessory SLD6 ACCKIT required Accessories (sold separately) lumens, wattage, CRI and CCT. SLD designer trims are accessory for mounting in 5 and 6 80 CRI. halo LED serialized testing and enclosed recessed housings 2700K, 3000K, 3500K, rings that attach to the SLD for a measurement ensures color May be installed in IC recessed and 4000K.

3 Permanent finish.* Refer to SLD and lumen consistency on a housings in direct contact with accessories specification sheet for per-unit basis, and validates insulation 80 2700K 80 3500K 80 4000 KSLD6129xxWHUNVJB. details. long-term product consistency * Note: Not for use in recessed White (Paintable) nominal over time nominal nominal housings in direct contact with Satin Nickel 90 CRI. CRI CRI CRI. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. spray foam insulation. Refer to ELECTRICAL CONNECTIONS. Tuscan Bronze 2700K, 3000K, 3500K, NEMA LSD 57-2013 J u n c t i o n B ox *SLD accessory trims attach with and 4000K. The SLD6 may be used with any Compatible with 4 x 2-1/8 deep permanent adhesion and are not 5 or 6 inch diameter recessed square boxes interchangeable after installation. housing constructed of steel Supply Wire Adapter with LED 6 Surface LED. 2700K nominal ELECTRICAL JUNCTION BOX. MOUNTING 80 3500K. or aluminum with an internal volume that exceeds in.

4 Nominal 80 4000K. quick connector included LED connector is a non- nominal Downlight SLD may be used in compatible High Lumen 1200 Series CRI CRI. screwbase luminaire disconnect 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. LED. electrical junction boxes in direct for tool-less installation Universal Voltage Linear LED arrays are contact with insulation including integrated in trim perimeter Optional - Recessed 120V-277V. spray foam insulation Housings Color Temperature: 2700K, 3000K, Suitable for installation in many Accessory SLD6 ACCKIT required. 4 x 2-1/8 deep square electrical 3500K, 4000K Suitable for CRI options: 80 and 90 LED connector is compatible with ceiling or wall junction boxes. 90 2700K 90 3500K 90 4000K. - 90 CRI can be used for halo 5 H550 Series and 6 H750, Driver consumes 3 cubic inches electrical junction boxes California Title 24 compliance/ H2750 Series LED Housings of junction box. nominal nominal LED Connector meets California nominal certified to Title 20 E N E R G Y DATA.

5 CRI. Compatible with other junction CRI CRI. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K. 4000K. - 80 CRI can be used to comply Title-24 high-efficacy luminaire boxes with accessory SLD6 EXT standard as a non-screw base 80 CRI 90 CRI. with California Title 24 Non- extension spacer ring. 90 CRIin a fire-rated Residential Lighting Controls Lumens Surface mounting 1215 1000. as a LED luminaire. (4000K models). ceiling using an LED. appropriate 2700K nominal electrical box offers a cost- effective alternative to Can fire-rated be used to comply WARRANTY. Refer to ENERGY STAR Certified Products List. Cooper Lighting with California . Title 24 High 90 3500K. provides nominal Certified to California Title 20 Appliance Efficiency Database. a five Efficacy requirements. 90 4000K nominal Input Voltage Frequency 120V-277V. 50/60 Hz 120V-277V. 50/60 Hz recessed housings year limited warranty on the CRI CRI. 2700K. 3000K. 3500K. 4000K. 2700K. 3000K. 3500K.

6 4000K. 2700K. 3000K. 3500K. 4000K. Note: Fire-rating is per the rating SLD LED Input Current A A. of the ceiling and applicable Input Power W W. Efficiency 82 lm/W 68 lm/W. (4000K models). 2700K 2700K. nominal CCT. nominal CCT. 80 90. THD 20%. 80 CRI. 3000K 3000K. LED Power Factor CRI 3500K. CRI 3500K. Refer to ENERGY STAR Certified Products List. Can be used to comply with California Title 24 Non-Residential T Ambient -30 - +40 C. 4000K 4000K as a LED Luminaire. Lighting Controls requirements Sound Rating Class A. NOMENCLATURE. 2700K 2700K. S L D 612 8 30 WH UNV JB. nominal CCT. nominal CCT. 3000K. 90 90 CRI. 3000K. LED. 612 = 6 SLD 1200 Series 8 = >80 CRI. 3500K. CRI 3500K. Refer to ENERGY STAR Certified Products List. Can be used to comply with California Title 24 High Efficacy requirements. 30 = 3000K. WH = Matte White 4000K 4000K Certified to California Title 20 Appliance Efficiency Database. UNV = Universal Voltage 120V-277V. JB = Junction Box Kit only TD518030EN .

7 10/22/2015. SLD6128xxWHUNVJB. SLD6129xxWHUNVJB. LED DRIVER EMI/RFI: meets FCC 47 CFR Part 15. 0-10V DC dimmers operate using Driver is a 120V-277V universal Class B limits, and is suitable for two low voltage dimming wires voltage input, high efficiency, use in residential and commercial (color coded violet and gray). The dimmable electronic power supply installations low voltage dimming wires are providing DC power to the LED Airtight certified per ASTM E283. separate from the 120V AC or arrays 277V AC power. (not exceeding CFM under 75. Driver features high power factor, Pascals pressure difference). Switching on/off is controlled low THD, and has integral thermal 90 CRI: Can be used to comply via the line voltage (120V AC or protection in the event of over with California Title 24 High 277V AC) power, and dimming is temperature or internal failure Efficacy requirements. Certified controlled via the 2-wire 0-10V DC. Driver is replaceable if it should be low voltage wiring.

8 To California Title 20 Appliance required Efficiency Database. COMPLIANCE. If dimming is not required the 80 CRI: Can be used to comply cULus Listed ceiling and wall fixutre may be operated from a cULus Damp Location listed with California Title 24 Non- SLD6 1200 UNV. switch Residential Lighting Controls ceiling and wall requirements as a LED luminaire. Series DIMMING - PHASE CONTROL cULus Wet Location Listed, ceiling Can be used for International Designed for continuous dimming only (shower rated). Energy Conservation Code (IECC). Universal Voltage capability to nominally 5% with Suitable for use in closets, and Washington State Energy SLD6128xxWHUNVJB. many 120V Leading Edge (LE) and compliant with NFPA 70, NEC . Code high efficiency luminaire Trailing Edge (TE) Phase Control Section (A)(3) and 80 CRI. compliance dimmers. (Dimmers with low (C)(5). ENERGY STAR certified 2700K, 3000K, 3500K, end trim adjustment offer greater SLD may be used in compatible luminaire - consult ENERGY and 4000K.)

9 Assurance of achieving 5% level.) electrical junction boxes in direct STAR Certified Product List Consult dimmer manufacturer for contact with insulation including Contains no mercury or lead and compatibility and conditions of spray foam insulation SLD6129xxWHUNVJB. RoHS compliant. use. With accessory SLD6 ACCKIT, (Note some dimmers require a may be installed in IC recessed Photometric testing in accordance 90 CRI. with IES LM-79 2700K, 3000K, 3500K, neutral in the wallbox.) housings in direct contact with Lumen maintenance projections insulation (Not for use in recessed and 4000K. DIMMING - 0-10V in accordance with IES LM-80 and housings in direct contact with Dimmable to 10% in typical TM-21. spray foam insulation. Refer to 6 Surface LED. operation with compatible 0-10V. NEMA LSD 57-2013) Downlight DC low voltage dimmers. High Lumen 1200 Series DIMENSIONS Universal Voltage 120V-277V.. [ ]. Suitable for ceiling or wall .8 electrical junction boxes [ ] [ ]..7 . [ ]. O R DE R I NG INFORMATIO N.

10 SAMPLE NUMBER: SLD612927 WHUNVJB SLD6 TRMSN. Junction Box Installation: Order junction box separately, as supplied by others, to complete installation. Recessed Installation: Order halo recessed housing separately to complete installation. Models Color Rendering Index Color Temperature (CCT) Finish Voltage Junction Box SLD612= 6 Surface LED 8=80 CRI 27=2700K WH=White UNV=Universal Voltage JB=Junction Box Kit only Downlight, 1200 Series 9=90 CRI 30=3000K 120V-277V. 35=3500K. 40=4000K. Accessories Designer Trims RAD Adapters Fit over the SLD for a designer finish When junction box is mounted flat on a ceiling or beam surface SLD6 TRMSN=6 SLD Satin Nickel (not recessed in ceiling). SLD6 TRMTBZ=6 SLD Tuscan Bronze SLD6 RAD=6 SLD Round Surface J-Box Adapter, SLD6 TRMWH=6 SLD White (paintable) (for 4-inch round or octagon junction boxes.). *SLD accessory trims attach with permanent adhesion and are not interchangable after SLD6 SADPLT=6 SLD Square Surface J-Box Adapter Plate installation (For 4-inch square junction boxes, use with SLD6 RAD.)