Example: dental hygienist

HARCO SDR-35 PVC GASKETED SEWER FITTINGS

HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA. Applicable Standards: 45 WYE (G x G x G). FITTINGS : ASTM F-1336. Materials: ASTM D-1784. Joints: ASTM D-3212. Gaskets: ASTM F-477. Installation: ASTM D-2321. L. BELL SPECIFICATION. A C. B. (Molded fitting shown). SIZE PART # STYLE C L WT (approx.). 4 35-010404 M 6x4 35-010604 M SPIGOT 6 35-010606 M C. 8x4 35-010804 M 8x6 35-010806 M 8 35-010808 M 10 x 4 35-011004 A 10 x 6 35-011006 M SIZE STYLE A B C Spigot 10 x 8 35-011008 F 4 M 10 35-011010 F 6 M 12 x 4 35-011204 A 8 M 12 x 6 35-011206 M 10 F/M / 12 x 8 35-011208 F 12 F/M / 12 x 10 35-011210 F 15 F 12 35-011212 F 15 x 4 35-011504 FTO DOUBLE WYE (G x G x G) 15 x 6 35-011506 F 15 x 8 35-011508 F 15 x 10 35-011510 FTO 15 x 12 35-011512 FTO 15 35-011515 FTO L. 45 WYE (G x S x G). C. (Molded fitting shown). SIZE PART # STYLE C L WT (approx.). 4 35-040404 F L. 6x4 35-040604 M 6 35-040606 M 8x4 35-040804 F 8x6 35-040806 F C.

HARCO SDR-35 PVC GASKETED SEWER FITTINGS DESIGN DATA. 4. Notes: • Call For Other Sizes, Configurations & Gasket Materials All lay lengths & weights are approximate and are subject to change without notice • Fabricated fitting configurations may vary. Style Legend: M - One Piece Molded .

Tags:

  Fitting, Sewer, Gasketed, Sdr 35, Gasketed sewer fittings

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of HARCO SDR-35 PVC GASKETED SEWER FITTINGS

1 HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA. Applicable Standards: 45 WYE (G x G x G). FITTINGS : ASTM F-1336. Materials: ASTM D-1784. Joints: ASTM D-3212. Gaskets: ASTM F-477. Installation: ASTM D-2321. L. BELL SPECIFICATION. A C. B. (Molded fitting shown). SIZE PART # STYLE C L WT (approx.). 4 35-010404 M 6x4 35-010604 M SPIGOT 6 35-010606 M C. 8x4 35-010804 M 8x6 35-010806 M 8 35-010808 M 10 x 4 35-011004 A 10 x 6 35-011006 M SIZE STYLE A B C Spigot 10 x 8 35-011008 F 4 M 10 35-011010 F 6 M 12 x 4 35-011204 A 8 M 12 x 6 35-011206 M 10 F/M / 12 x 8 35-011208 F 12 F/M / 12 x 10 35-011210 F 15 F 12 35-011212 F 15 x 4 35-011504 FTO DOUBLE WYE (G x G x G) 15 x 6 35-011506 F 15 x 8 35-011508 F 15 x 10 35-011510 FTO 15 x 12 35-011512 FTO 15 35-011515 FTO L. 45 WYE (G x S x G). C. (Molded fitting shown). SIZE PART # STYLE C L WT (approx.). 4 35-040404 F L. 6x4 35-040604 M 6 35-040606 M 8x4 35-040804 F 8x6 35-040806 F C.

2 Notes: All lay lengths & weights are approximate and are subject to SIZE PART # STYLE C L WT (approx.). change without notice 4 35-020404 M Fabricated fitting configurations may vary 6x4 35-020604 M 6 35-020606 M Style Legend: 8x4 35-020804 M M - One Piece Molded 8x6 35-020806 M A- Assembled from Molded Components 8 35-020808 M F- Fabricated FTO - Fabricated To Order Call For Other Sizes, Configurations & Gasket Materials CAUTION: Vertical risers are not recommended Vertical risers are subject to problems without special consideration of soil/pipe interaction, dead & live loads, and installation procedures. THE HARRINGTON CORPORATION. BOX 10335 LYNCHBURG, VIRGINIA 24506 3721 COHEN PLACE LYNCHBURG, VIRGINIA 24501. PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: WEB: 8/17/18. HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA. TEE (G x G x G) MANHOLE ADAPTERS (Double Bell). A. Note: Adapter has a sand coated exterior surface L L.

3 (Molded fitting shown). SIZE PART # STYLE A L WT (approx.). 4 35-5704 M A (Molded fitting shown) 6 35-5706 M SIZE PART # STYLE A L WT (approx.) 8 35-5708 M 4 35-120404 M 10 35-5710 F 6x4 35-120604 M 12 35-5712 F 6 35-120606 M 15 35-5715 F 8x4 35-120804 M 8x6 35-120806 M COUPLING (w/ Stop). 8 35-120808 M 10 x 4 35-121004 F 10 x 6 35-121006 F L. 10 x 8 35-121008 F 10 35-121010 F 12 x 4 35-121204 F (Molded fitting shown). 12 x 6 35-121206 F SIZE PART # STYLE L WT (approx.). 12 x 8 35-121208 F 4 35-0804 M 12 x 10 35-121210 F 6 35-0806 M 12 35-121212 F 8 35-0808 M 15 x 4 35-121504 F 10 35-0810 F 15 x 6 35-121506 F 12 35-0812 F 15 x 8 35-121508 F 15 35-0815 F 15 x 10 35-121510 F 15 x 12 35-121512 F 15 35-121515 F REPAIR COUPLING (No Stop - Sleeve). MANHOLE ADAPTERS (Single Bell). L. A. Note: Adapter has a sand coated exterior surface (Molded fitting shown). SIZE PART # STYLE L WT (approx.). L. 4 35-0904 M (Molded fitting shown) 6 35-0906 M SIZE PART # STYLE A L WT (approx.)

4 8 35-0908 M 10 35-0910 F 4 35-5804 M 12 35-0912 F 6 35-5806 M 15 35-0915 F 8 35-5808 M 10 35-5810 F 12 35-5812 F CAP. 15 35-5815 F Notes: L. All lay lengths & weights are approximate and are subject to (Molded fitting shown). change without notice SIZE PART # STYLE L WT (approx.). Fabricated fitting configurations may vary 4 35-4904 M Style Legend: 6 35-4906 M 8 35-4908 M M - One Piece Molded F- Fabricated 10 35-4910 F 12 35-4912 F CAUTION: Vertical risers are not recommended 15 35-4915 F Vertical risers are subject to problems without special consideration of soil/pipe interaction, dead & live loads, and installation procedures. Call For Other Sizes, Configurations & Gasket Materials THE HARRINGTON CORPORATION. BOX 10335 LYNCHBURG, VIRGINIA 24506 3721 COHEN PLACE LYNCHBURG, VIRGINIA 24501. PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: WEB: 8/17/18. HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA.

5 90 BEND (G x G) 90 BEND (G x S). L. (Molded fitting shown) (Molded fitting shown). SIZE PART # STYLE L WT (approx.) SIZE PART # STYLE L WT (approx.). 4 35-1804 M 4 35-1904 M 6 35-1806 M 6 35-1906 M 8 35-1808 M 8 35-1908 M 10 35-1810 F 10 35-1910 F 12 35-1812 F 12 35-1912 F 15 35-1815 F 15 35-1915 F 45 BEND (G x G) 45 BEND (G x S). L L. L. (Molded fitting shown) (Molded fitting shown). SIZE PART # STYLE L WT (approx.) SIZE PART # STYLE L WT (approx.). 4 35-2204 M 4 35-2304 M 6 35-2206 M 6 35-2306 M 8 35-2208 M 8 35-2308 M 10 35-2210 F 10 35-2310 F 12 35-2212 F 12 35-2312 F 15 35-2215 F 15 35-2315 F BEND (G x G) BEND (G x S). L L. L. (Molded fitting shown) (Molded fitting shown). SIZE PART # STYLE L WT (approx.) SIZE PART # STYLE L WT (approx.). 4 35-2404 M 4 35-2504 M 6 35-2406 M 6 35-2506 M 8 35-2408 M 8 35-2508 M 10 35-2410 F 10 35-2510 F 12 35-2412 F 12 35-2512 F 15 35-2415 F 15 35-2515 F Notes: All lay lengths & weights are approximate and are subject to Call For Other Sizes, Configurations & Gasket Materials change without notice Fabricated fitting configurations may vary CAUTION: Vertical risers are not recommended Vertical risers are subject to problems without special consideration Style Legend: of soil/pipe interaction, dead & live loads, and installation M - One Piece Molded procedures.

6 F- Fabricated THE HARRINGTON CORPORATION. BOX 10335 LYNCHBURG VIRGINIA 24506 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501. PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: WEB: 8/17/18. HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA. TEE-WYE (G x G x G) PERMANENT PLUG. A. B. L C (Molded fitting shown). SIZE PART # STYLE A B WT (approx.). 4 35-4404 M 6 35-4406 M (Molded fitting shown) 8 35-4408 M SIZE PART # STYLE C L WT (approx.) 10 35-4410 F 4 35-050404 M 12 35-4412 F 6x4 35-050604 M 15 35-4415 F 6 35-050606 M 8x4 35-050804 M TEMPORARY PLUG. 8x6 35-050806 M 8 35-050808 M 10 x 4 35-051004 A L. 10 x 6 35-051006 M (Polyethylene). 12 x 4 35-051204 A SIZE PART # STYLE L WT (approx.). 12 x 6 35-051206 M 4 35-4704 M 15 x 4 35-051504 F 6 35-4706 M 15 x 6 35-051506 F 8 35-4708 M TEE-WYE (G x S x G) SADDLE WYE. A. L C. (Saddle gasket & SS straps not shown). SIZE PART # STYLE A WT (approx.). 6x4 35-550604 M 8x4 35-550804 M SIZE PART # STYLE C L WT (approx.)

7 8x6 35-550806 M 4 35-060404 M 10 x 4 35-551004 M 6x4 35-060604 M 10 x 6 35-551006 M 6 35-060606 M 12 x 4 35-551204 M 8x4 35-060804 M 12 x 6 35-551206 M 8x6 35-060806 M 8 35-060808 M SADDLE TEE. Notes: All lay lengths & weights are approximate and are subject to A. change without notice Fabricated fitting configurations may vary (Saddle gasket & SS straps not shown). SIZE PART # STYLE A WT (approx.). Style Legend: M - One Piece Molded 6x4 35-560604 M A- Assembled from Molded Components 8x4 35-560804 M F- Fabricated 8x6 35-560806 M 10 x 4 35-561004 M CAUTION: Vertical risers are not recommended 10 x 6 35-561006 M Vertical risers are subject to problems without special consideration 12 x 4 35-561204 M of soil/pipe interaction, dead & live loads, and installation procedures. 12 x 6 35-561206 M Call For Other Sizes, Configurations & Gasket Materials THE HARRINGTON CORPORATION. BOX 10335 LYNCHBURG VIRGINIA 24506 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501.

8 PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: WEB: 8/17/18. HARCO SDR-35 PVC GASKETED SEWER FITTINGS . DESIGN DATA. CONCENTRIC INCREASER (G x S) CLEAN-OUT PLUG (RAISED). B. A. (Molded fitting shown). L SIZE PART # A B WT (approx.). 4 35-6104 6 35-6106 (Molded fitting shown). SIZE PART # STYLE L WT (approx.) CLEAN-OUT PLUG (RECESSED). 4x6 35-160406 M 4x8 35-160408 F 4 x 10 35-160410 F 4 x 12 35-160412 F A (Molded fitting shown). 4 x 15 35-160415 FTO SIZE PART # A L WT (approx.). 6x8 35-160608 M 4 35-6204 6 x 10 35-160610 F 6 35-6206 6 x 12 35-160612 F 6 x 15 35-160615 FTO 8 x 10 35-160810 F CLEAN-OUT ADAPTER (HUB). 8 x 12 35-160812 F 8 x 15 35-160815 FTO 10 x 12 35-161012 F L B. 10 x 15 35-161015 FTO 12 x 15 35-161215 F (Molded fitting shown). SIZE PART # A B L WT (approx.). ADAPTER - SEWER x DWV (S x S) 4 35-5904 L 6 35-5906 A. CLEAN-OUT ADAPTER (SPIGOT). SIZE PART # STYLE A L WT (approx.). 4 35-4004 M L.

9 B. 6 35-4006 M (Molded fitting shown). ADAPTER - SEWER x DWV (S x G) SIZE PART # A B L WT (approx.). L 4 35-6004 6 35-6006 2-WAY CLEAN-OUT TEE. A L. SIZE PART # STYLE A L WT (approx.). 4 35-3504 M 6 35-3506 M A. NOTES: All lay lengths & weights are approximate and are subject to change without notice Fabricated fitting configurations may vary SIZE PART # STYLE A L WT (approx.). Style Legend: 4 35-1304 F M - One Piece Molded F- Fabricated FTO Fabricated To Order CAUTION: Vertical risers are not recommended Call For Other Sizes, Configurations & Gasket Materials Vertical risers are subject to problems without special consideration f / &. THE HARRINGTON CORPORATION. BOX 10335 LYNCHBURG VIRGINIA 24506 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501. PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: WEB: 8/17/18.