Example: quiz answers

Harmony XALD, XALK plastic control stations - …

Harmony XALD, XALK plastic control stationsFor Harmony XB5, control and signaling units 22 CatalogOctober 2013 How to find the Automation and control productsCatalogsComplete product rangesEssential guidesSelection of the top selling products1 Harmony XALD, XALK plastic control stationsSelection guide .. page 2 bGeneral vPresentation of range ..page 4 bReferences vComplete stations (Screw clamp terminal connections) ..page 6 vStations for customer assembly: empty enclosures ..page 10 vStations for customer assembly: electical blocks ..page 11 vStations for customer assembly: heads.

Harmony® XALD, XALK plastic control stations For Harmony® XB5, control and signaling units Ø 22 Catalog October 2013

Tags:

  2013, October, October 2013

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Harmony XALD, XALK plastic control stations - …

1 Harmony XALD, XALK plastic control stationsFor Harmony XB5, control and signaling units 22 CatalogOctober 2013 How to find the Automation and control productsCatalogsComplete product rangesEssential guidesSelection of the top selling products1 Harmony XALD, XALK plastic control stationsSelection guide .. page 2 bGeneral vPresentation of range ..page 4 bReferences vComplete stations (Screw clamp terminal connections) ..page 6 vStations for customer assembly: empty enclosures ..page 10 vStations for customer assembly: electical blocks ..page 11 vStations for customer assembly: heads.

2 Page 12 vStations for customer assembly: accessories ..page 21 bHow to find the Automation and control products vSearch, visualize, and download ..page 28 vAccess product references with adapted tools ..page 30 vCompare, select, and compile ..page 32 vCheck the product status, design your equipment ..page 33 bProduct reference index ..page 34 General contents21345678910213456789102112233445 566778899101023 Type of applicationsAll applicationsSpecific applicationsEnclosuresPlasticGlass-reinf orced polyesterMetalMetal front plate, insulated protective rear coverPlasticMetalComplete stations and separate components for customer assemblyEmpty insulated enclosuresEmpty enclosuresEmpty, flush mounting enclosures.

3 Front plate + rear coverControl stations for severe environmentsLift inspection stationsKey operated control stations Main featurePre-drilled control stationsPre-drilled or undrilled enclosuresPre-drilled enclosuresPre-drilled or undrilled enclosuresPre-drilled front plates & rear coversPre-drilled empty control stationsPre-drilled empty enclosures or fitted stations Fitted stationsAssociated control and signalling units Harmony XB5 with plastic bezel Harmony XB7, monolithic, plasticHarmony XB4 with metal bezelHarmony XB5 with plastic bezelHarmony XB4 with metal bezelHarmony XB5 with plastic bezelHarmony XB5 with plastic bezelHarmony XB5 or XB7 with plastic bezelWith key lockNumber of cut-outs for 22 control and signalling units1, 2, 3, 4 or 5 1, 2 or 3 (complete stations )1, 2, 3, 4 or 5 (empty enclosures)

4 1, 2 or 31, 2, 4, 8 or 168, 16, 24, 30 or 401, 2, 3, 4, 6, 8 or 121, 2, 3, 4 or 51, 2, 3, 4 or 51, 2, 3, 4, 5 or 6 with or without power socket MaterialPolycarbonateABSG lass-reinforced polyesterAluminium alloy or sheet steelZinc or aluminium alloyFront plate: brushed aluminium Rear cover:polystyreneMineral reinforced polyamidePolycarbonateZinc alloy ColourYellow lid Light grey baseDark grey lid Light grey baseLight grey or yellow lid Light grey base Coloured grey throughoutBlue lid and baseXAPM: Blue lidBlue baseXAPJ:Yellow lidBlue baseUnpainted aluminiumBlack lid Black baseYellow lidLight grey baseGreyDegree of protectionIP 66 / NEMA Enclosure type 4, 4X and 13IP 54IP 65IP 54IP 65IP 66IP 69 KIP 44 (with power socket)IP 55 or IP 66 depending on modelIP 54 FunctionEmergency Stop or Emergency switching offStart or StopStart-Stop with pilot lightMotion controlAccording to equipment fitted: vStart or Stop vStart-Stop with pilot light vMotion control vEmergency stopAccording to equipment fitted.

5 VStart or Stop vStart-Stop with pilot light vMotion control vEmergency stopStart-StopCable entriesKnock-outs(CM12)Knock-outs(ISO 20)Undrilled vTapped entries for cable-glands vor undrilledTapped entries for cable-glandsKnock-outs (with protective rear cover)Two ISO 20 open entries vKnock-outs (CM12) vor undrilledTapped for cable- glandsType referencesXALKXALDXALEXAPAXB2 SLXAPM, XAPJXAPEXALGXALFXAPSS election guide control stations and enclosures4 ZBE101 ZBE102ZB5AZ009 ZENL1111 ZENL1121 ZENL1121 ZENL1121 ZENL1121ZB5AW358ZB5AV033ZB5AG0ZB5AD0203Z B5AS944ZB5AS844 ZBZ32ZB5AL434ZB5AP3 SZB5AA333 ZBVppZALVppGeneral control stations and enclosures plastic control stations XALD and XALKFor Harmony XB5 control and signaling units 225 GeneralControl stations and enclosures plastic control stations XALD and XALKFor Harmony XB5 control and signaling units 22 References:page 6 XALD and XALK control stations are available in two forms.

6 B Completeb For customer assemblyThese control stations use the plastic bezel pushbuttons, switches and pilot lights of the Harmony XB5 range, which offers a wide choice of circular and square types of pre-assembled stationsThese are complete, ready to install, stations fitted with 1 to 3 buttons to cater for the most commonly encountered functions:b Start or Stop, with: v 1 flush spring return pushbutton,v 1 red, spring return, mushroom head Emergency stop or Emergency switching off, with:v 1 red, latching, mushroom head pushbutton 3, either push-pull or turn to release, with or without Start-Stop, with:v 2 flush spring return pushbuttons, v 1 flush spring return pushbutton 1 + 1 projecting spring return pushbutton 2, v 1 2-position selector switch 4 + 1 pilot light with integral red LED, if Two functions, with:v 2 flush spring return pushbuttons Three functions, with.

7 V 3 flush spring return pushbuttons 1, v 2 flush spring return pushbuttons 1 + 1 projecting spring return pushbutton 2,v 2 flush spring return pushbuttons 1 + 1 red, latching, mushroom head pushbutton pushbuttons, switches and pilot lights comprise plastic heads from the Harmony XB5 range and electrical blocks (contact or light) 8 that are mounted in the back of the for customer assembliesThese stations are for assembly by the user and offer a choice of 2 assembly methods:b Box methodIdentical to the pre-assembled versions. The electrical blocks 8 are mounted on a metal mounting plate in the back of the enclosure Station methodThe electrical blocks 9 are mounted directly beneath the heads using a body/fixing collar is possible to assemble stations with 1 to 5 heads, each of which can be combined with 3 electrical blocks 8 or 9 (contact or light).

8 The XAL range offers a wide choice of head types for:b Spring return pushbuttons 1 or 2, either marked or unmarkedb Spring return mushroom head pushbuttonsb Latching mushroom head pushbuttons 3b Selector switches with standard or long handle and key switches 4b Toggle switchesb Pilot lights 5b Illuminated spring return pushbuttons 6 Illuminated selector switches with standard handle for headsMarkings can be customised by using legend holders 11 which can either be fitted with pre-marked legends or legends engraved by the user. Alternatively, paper legends (protected), prepared using SIS Label software 12, or peel-off legends (supplied on sheet for marking by laser printer) can be and colorsb Start-Stop control stations (XALD):light grey base RAL 7035 , dark grey lid RAL 7016 b control stations with Emergency stop or Emergency switching off functions (XALK): light grey RAL 7035 base, yellow RAL 7021 lidb Lid fixing screws and nut material: stainless steel type A4, AISI Protection degree: IP 66 (EN/IEC 60529) and UL/CSA Enclosure type 4, 4X and High pressure cleaning resistance.

9 70 x 105 Pa (70 bars), distance m (temp. 55 C)b Ambiant air temperature for operation: - 25 to + 70 Cb Conformity to standards : v EN/IEC 60947-5-1, 60947-5-4 for Start-Stop control stations ,v EN/IEC 60204-1 and EN/ISO 13850 for control stations with Emergency stop function, v IEC 60364-5-53 for control stations with Emergency switching off Product certifications : UL Listed, CSA, Knock-out entries for cable-gland (CM 12, Pg and tapped ISO 20).b Knock-outs for cable entry through or Stop functionb Light grey RAL 7035 base, dark grey RAL 7016 lidDescriptionType of pushDimensions (1)w x h x dmmType of contactMarkingReferenceWeightkgN/ON/CMar king on pushbutton1 spring return pushbuttonFlush, green68 x 68 x 621 IXALD102 (2) (2) (2) , red68 x 68 x 62 (2) , red68 x 68 x 1 OXALD115 (2) on legend holder and legend below head1 spring return pushbuttonFlush, green68 x 68 x 621 MarcheXALD101 (2) (2) , red68 x 68 x 62 1 Arr (2)

10 Mushroom head pushbutton, 40 mm, spring returnRed68 x 68 x 86 1 Arr tXALD164 (2) (1) Please see our website www .schneider-electric .com for more precised information about dimensions of components .(2) Please add H7 for UL/CSA conformity, example: XALK102H7 . control stations and enclosures plastic control stations XALD and XALKFor Harmony XB5 control and signaling units 22 Complete stations (screw clamp terminal connections) 815193 XALD164815192 XALD111815191 XALD101815190 XALD115815189 XALD102 General:page 472 Emergency stop function: Mushroom head Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850.


Related search queries